LIYCY-TP

Signal Cables
Used in areas requiring protection against electromagnetic interference (EMI) in automation and control systems, industrial electronics, computers and office machines, internal communications, sound systems, and security systems.

Technical Specifications
Product
0,5 mm²
7.7 mm
39 Ω/km
72 kg/km
6 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
8.3 mm
39 Ω/km
88 kg/km
6 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
9 mm
39 Ω/km
106 kg/km
6 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
10.3 mm
39 Ω/km
122 kg/km
6 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
11.1 mm
39 Ω/km
154 kg/km
6 A
Number of Pairs
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
11.1 mm
39 Ω/km
166 kg/km
6 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
12.4 mm
39 Ω/km
192 kg/km
6 A
Number of Pairs
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
14.1 mm
39 Ω/km
235 kg/km
6 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
14.3 mm
39 Ω/km
262 kg/km
6 A
Number of Pairs
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
15.2 mm
39 Ω/km
300 kg/km
6 A
Number of Pairs
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
16.4 mm
39 Ω/km
340 kg/km
6 A
Number of Pairs
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
17.2 mm
39 Ω/km
372 kg/km
6 A
Number of Pairs
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,5 mm²
18.2 mm
39 Ω/km
407 kg/km
6 A
Number of Pairs
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
8.3 mm
26 Ω/km
85 kg/km
13 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
9 mm
26 Ω/km
103 kg/km
13 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
10 mm
26 Ω/km
124 kg/km
13 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
11 mm
26 Ω/km
152 kg/km
13 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
12.4 mm
26 Ω/km
203 kg/km
13 A
Number of Pairs
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
13.1 mm
26 Ω/km
220 kg/km
13 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
13.7 mm
26 Ω/km
243 kg/km
13 A
Number of Pairs
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
15.3 mm
26 Ω/km
296 kg/km
13 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
15.6 mm
26 Ω/km
331 kg/km
13 A
Number of Pairs
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
16.8 mm
26 Ω/km
383 kg/km
13 A
Number of Pairs
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
17.9 mm
26 Ω/km
432 kg/km
13 A
Number of Pairs
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
18.9 mm
26 Ω/km
473 kg/km
13 A
Number of Pairs
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
0,75 mm²
20 mm
26 Ω/km
534 kg/km
13 A
Number of Pairs
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
9 mm
19.5 Ω/km
100 kg/km
16 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
9.9 mm
19.5 Ω/km
128 kg/km
16 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
10.6 mm
19.5 Ω/km
163 kg/km
16 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
12.5 mm
19.5 Ω/km
206 kg/km
16 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
13.6 mm
19.5 Ω/km
245 kg/km
16 A
Number of Pairs
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
14 mm
19.5 Ω/km
266 kg/km
16 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
14.6 mm
19.5 Ω/km
293 kg/km
16 A
Number of Pairs
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
16.9 mm
19.5 Ω/km
364 kg/km
16 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
17.3 mm
19.5 Ω/km
416 kg/km
16 A
Number of Pairs
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
18.3 mm
19.5 Ω/km
473 kg/km
16 A
Number of Pairs
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
19.5 mm
19.5 Ω/km
534 kg/km
16 A
Number of Pairs
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
20.5 mm
19.5 Ω/km
588 kg/km
16 A
Number of Pairs
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1 mm²
21.7 mm
19.5 Ω/km
646 kg/km
16 A
Number of Pairs
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
9.8 mm
13.3 Ω/km
130 kg/km
20 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
10.5 mm
13.3 Ω/km
160 kg/km
20 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
11.5 mm
13.3 Ω/km
200 kg/km
20 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
13.2 mm
13.3 Ω/km
251 kg/km
20 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
14.3 mm
13.3 Ω/km
293 kg/km
20 A
Number of Pairs
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
15.2 mm
13.3 Ω/km
326 kg/km
20 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
15.7 mm
13.3 Ω/km
362 kg/km
20 A
Number of Pairs
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
18 mm
13.3 Ω/km
450 kg/km
20 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
18.5 mm
13.3 Ω/km
516 kg/km
20 A
Number of Pairs
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
19.7 mm
13.3 Ω/km
589 kg/km
20 A
Number of Pairs
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
21 mm
13.3 Ω/km
668 kg/km
20 A
Number of Pairs
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
22 mm
13.3 Ω/km
735 kg/km
20 A
Number of Pairs
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
1,5 mm²
24 mm
13.3 Ω/km
832 kg/km
20 A
Number of Pairs
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
12.5 mm
7.98 Ω/km
200 kg/km
25 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
13.3 mm
7.98 Ω/km
281 kg/km
25 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
14.7 mm
7.98 Ω/km
315 kg/km
25 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
16.5 mm
7.98 Ω/km
391 kg/km
25 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
18 mm
7.98 Ω/km
461 kg/km
25 A
Number of Pairs
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
19.1 mm
7.98 Ω/km
514 kg/km
25 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
19.8 mm
7.98 Ω/km
674 kg/km
25 A
Number of Pairs
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
22.8 mm
7.98 Ω/km
723 kg/km
25 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
23.3 mm
7.98 Ω/km
836 kg/km
25 A
Number of Pairs
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
24.9 mm
7.98 Ω/km
958 kg/km
25 A
Number of Pairs
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
26.6 mm
7.98 Ω/km
1098 kg/km
25 A
Number of Pairs
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
28.5 mm
7.98 Ω/km
1235 kg/km
25 A
Number of Pairs
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2,5 mm²
30.2 mm
7.98 Ω/km
1362 kg/km
25 A
Number of Pairs
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Title Type Language
LIYCY-TP Ürün Ana Görseli PNG
LIYCY-TP Ürün Kataloğu PDF
LIYCY-TP Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1