LIYCY

Signal Cables
Used in areas requiring protection against electromagnetic interference (EMI) in automation and control systems, industrial electronics, computers and office machines, internal communications, sound systems, and security systems.

Technical Specifications
Product
10x0,5 mm²
8.9 mm
39 Ω/km
127 kg/km
6 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
10x0,75 mm²
10 mm
26 Ω/km
165 kg/km
13 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
10x1 mm²
10.6 mm
19.5 Ω/km
197 kg/km
16 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
10x1,5 mm²
12.8 mm
13.3 Ω/km
285 kg/km
20 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
10x2,5 mm²
14.8 mm
7.98 Ω/km
410 kg/km
25 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
12x0,5 mm²
9.1 mm
39 Ω/km
143 kg/km
6 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
12x0,75 mm²
10.4 mm
26 Ω/km
190 kg/km
13 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
12x1 mm²
10.9 mm
19.5 Ω/km
223 kg/km
16 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
12x1,5 mm²
13.3 mm
13.3 Ω/km
330 kg/km
20 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
12x2,5 mm²
15.4 mm
7.98 Ω/km
476 kg/km
25 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
14x0,5 mm²
9.6 mm
39 Ω/km
167 kg/km
6 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
14x0,75 mm²
10.9 mm
26 Ω/km
218 kg/km
13 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
14x1 mm²
11.5 mm
19.5 Ω/km
261 kg/km
16 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
14x1,5 mm²
13.9 mm
13.3 Ω/km
381 kg/km
20 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
14x2,5 mm²
16.3 mm
7.98 Ω/km
563 kg/km
25 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
16x0,5 mm²
10.1 mm
39 Ω/km
185 kg/km
6 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
16x0,75 mm²
11.5 mm
26 Ω/km
246 kg/km
13 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
16x1 mm²
12.3 mm
19.5 Ω/km
298 kg/km
16 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
16x1,5 mm²
14.7 mm
13.3 Ω/km
429 kg/km
20 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
16x2,5 mm²
17.3 mm
7.98 Ω/km
634 kg/km
25 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
18x0,5 mm²
10.7 mm
39 Ω/km
203 kg/km
6 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
18x0,75 mm²
12.3 mm
26 Ω/km
273 kg/km
13 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
18x1 mm²
12.9 mm
19.5 Ω/km
323 kg/km
16 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
18x1,5 mm²
15.6 mm
13.3 Ω/km
469 kg/km
20 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
18x2,5 mm²
18.3 mm
7.98 Ω/km
694 kg/km
25 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
20x0,5 mm²
11.4 mm
39 Ω/km
225 kg/km
6 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
20x0,75 mm²
12.9 mm
26 Ω/km
298 kg/km
13 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
20x1 mm²
13.7 mm
19.5 Ω/km
357 kg/km
16 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
20x1,5 mm²
16.6 mm
13.3 Ω/km
525 kg/km
20 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
20x2,5 mm²
19.4 mm
7.98 Ω/km
779 kg/km
25 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
24x0,5 mm²
12.5 mm
39 Ω/km
254 kg/km
6 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
24x0,75 mm²
13.8 mm
26 Ω/km
330 kg/km
13 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
24x1 mm²
15 mm
19.5 Ω/km
409 kg/km
16 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
24x1,5 mm²
17.6 mm
13.3 Ω/km
575 kg/km
20 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
24x2,5 mm²
20.6 mm
7.98 Ω/km
853 kg/km
25 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
25x0,5 mm²
12.7 mm
39 Ω/km
278 kg/km
6 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
25x0,75 mm²
14.4 mm
26 Ω/km
367 kg/km
13 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
25x1 mm²
15.3 mm
19.5 Ω/km
441 kg/km
16 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
25x1,5 mm²
18.5 mm
13.3 Ω/km
647 kg/km
20 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
25x2,5 mm²
21.1 mm
7.98 Ω/km
882 kg/km
25 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2x0,5 mm²
5 mm
39 Ω/km
38 kg/km
6 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2x0,75 mm²
5.6 mm
26 Ω/km
48 kg/km
13 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2x1 mm²
5.8 mm
19.5 Ω/km
54 kg/km
16 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2x1,5 mm²
7 mm
13.3 Ω/km
77 kg/km
20 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
2x2,5 mm²
8.1 mm
7.98 Ω/km
108 kg/km
25 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
3x0,5 mm²
5.2 mm
39 Ω/km
46 kg/km
6 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
3x0,75 mm²
5.8 mm
26 Ω/km
58 kg/km
13 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
3x1 mm²
6.2 mm
19.5 Ω/km
68 kg/km
16 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
3x1,5 mm²
7.3 mm
13.3 Ω/km
95 kg/km
20 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
3x2,5 mm²
8.5 mm
7.98 Ω/km
137 kg/km
25 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
4x0,5 mm²
5.7 mm
39 Ω/km
56 kg/km
6 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
4x0,75 mm²
6.4 mm
26 Ω/km
72 kg/km
13 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
4x1 mm²
6.8 mm
19.5 Ω/km
86 kg/km
16 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
4x1,5 mm²
8.1 mm
13.3 Ω/km
123 kg/km
20 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
4x2,5 mm²
9.3 mm
7.98 Ω/km
173 kg/km
25 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
5x0,5 mm²
6.3 mm
39 Ω/km
71 kg/km
6 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
5x0,75 mm²
7 mm
26 Ω/km
92 kg/km
13 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
5x1 mm²
7.5 mm
19.5 Ω/km
110 kg/km
16 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
5x1,5 mm²
9 mm
13.3 Ω/km
158 kg/km
20 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
5x2,5 mm²
10.4 mm
7.98 Ω/km
226 kg/km
25 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
6x0,5 mm²
6.9 mm
39 Ω/km
84 kg/km
6 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
6x0,75 mm²
7.7 mm
26 Ω/km
108 kg/km
13 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
6x1 mm²
8.2 mm
19.5 Ω/km
129 kg/km
16 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
6x1,5 mm²
9.8 mm
13.3 Ω/km
185 kg/km
20 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
6x2,5 mm²
11.4 mm
7.98 Ω/km
265 kg/km
25 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
7x0,5 mm²
6.9 mm
39 Ω/km
87 kg/km
6 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
7x0,75 mm²
7.7 mm
26 Ω/km
113 kg/km
13 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
7x1 mm²
8.2 mm
19.5 Ω/km
135 kg/km
16 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
7x1,5 mm²
9.8 mm
13.3 Ω/km
195 kg/km
20 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
7x2,5 mm²
11.4 mm
7.98 Ω/km
282 kg/km
25 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
8x0,5 mm²
7.5 mm
39 Ω/km
103 kg/km
6 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
8x0,75 mm²
8.4 mm
26 Ω/km
134 kg/km
13 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
8x1 mm²
8.9 mm
19.5 Ω/km
160 kg/km
16 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
8x1,5 mm²
10.7 mm
13.3 Ω/km
231 kg/km
20 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
8x2,5 mm²
12.5 mm
7.98 Ω/km
337 kg/km
25 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
9x0,5 mm²
8.1 mm
39 Ω/km
117 kg/km
6 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
9x0,75 mm²
9.1 mm
26 Ω/km
151 kg/km
13 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
9x1 mm²
9.7 mm
19.5 Ω/km
180 kg/km
16 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
9x1,5 mm²
11.6 mm
13.3 Ω/km
259 kg/km
20 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
9x2,5 mm²
13.6 mm
7.98 Ω/km
378 kg/km
25 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Braid
Tape
Polyester
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Title Type Language
LIYCY CE Kalite Sertifikası PDF
LIYCY DOP Kalite Sertifikası PDF
LIYCY TSE Kalite Sertifikası PDF
LIYCY Ürün Ana Görseli PNG
LIYCY Ürün Kataloğu PDF
LIYCY Ürün Kesit Görseli JPG
How can we help you?