LIHH-TP FE180/PH120

Signal Cables
These cables have low smoke density and are used in smart or semi-smart buildings, in enclosed spaces where people are densely populated or where valuable items are located, for controlling devices that need to operate during a fire, in industrial electronics, computers and office machines, internal communications, and internal sound systems, in places where the protection of human life and important materials is necessary.

Halogen Free
Technical Specifications
Product
0,5 mm²
7.5 mm
39 Ω/km
64 kg/km
6 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
8 mm
39 Ω/km
82 kg/km
6 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
8.8 mm
39 Ω/km
102 kg/km
6 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
9.7 mm
39 Ω/km
124 kg/km
6 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
10.8 mm
39 Ω/km
165 kg/km
6 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
14 mm
39 Ω/km
243 kg/km
6 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
8.4 mm
26 Ω/km
81 kg/km
13 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
9 mm
26 Ω/km
106 kg/km
13 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
10 mm
26 Ω/km
136 kg/km
13 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
11 mm
26 Ω/km
166 kg/km
13 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
12.2 mm
26 Ω/km
218 kg/km
13 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
15.8 mm
26 Ω/km
319 kg/km
13 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
8.9 mm
19.5 Ω/km
96 kg/km
16 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
9.6 mm
19.5 Ω/km
126 kg/km
16 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
10.5 mm
19.5 Ω/km
160 kg/km
16 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
11.7 mm
19.5 Ω/km
197 kg/km
16 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
12.9 mm
19.5 Ω/km
260 kg/km
16 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
16.8 mm
19.5 Ω/km
382 kg/km
16 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
10.7 mm
13.3 Ω/km
141 kg/km
20 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
11.5 mm
13.3 Ω/km
184 kg/km
20 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
12.8 mm
13.3 Ω/km
235 kg/km
20 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
14.1 mm
13.3 Ω/km
286 kg/km
20 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
15.5 mm
13.3 Ω/km
377 kg/km
20 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
20.1 mm
13.3 Ω/km
551 kg/km
20 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
Title Type Language
LIHH-TP FE180/PH120 Ürün Ana Görseli PNG
LIHH-TP FE180/PH120 Ürün Kataloğu PDF
LIHH-TP FE180/PH120 Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1