LIHH FE180/PH120

Signal Cables
Used in areas with very high fire safety requirements, in automation and control systems, industrial electronics, in signal transmission, building communication systems, and security and fire alarm systems.

Halogen Free
Technical Specifications
Product
10x0,5 mm²
9.1 mm
39 Ω/km
101 kg/km
6 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
10x0,75 mm²
9.9 mm
26 Ω/km
129 kg/km
13 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
10x1 mm²
10.7 mm
19.5 Ω/km
158 kg/km
16 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
10x1,5 mm²
12.5 mm
13.3 Ω/km
222 kg/km
20 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
10x2,5 mm²
14.3 mm
7.98 Ω/km
322 kg/km
25 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
12x0,5 mm²
9.4 mm
39 Ω/km
116 kg/km
6 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
12x0,75 mm²
10.2 mm
26 Ω/km
149 kg/km
13 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
12x1 mm²
11.1 mm
19.5 Ω/km
183 kg/km
16 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
12x1,5 mm²
12.9 mm
13.3 Ω/km
258 kg/km
20 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
12x2,5 mm²
14.8 mm
7.98 Ω/km
376 kg/km
25 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
14x0,5 mm²
9.8 mm
39 Ω/km
131 kg/km
6 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
14x0,75 mm²
10.7 mm
26 Ω/km
169 kg/km
13 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
14x1 mm²
11.8 mm
19.5 Ω/km
214 kg/km
16 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
14x1,5 mm²
13.6 mm
13.3 Ω/km
295 kg/km
20 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
14x2,5 mm²
15.6 mm
7.98 Ω/km
433 kg/km
25 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
16x0,5 mm²
10.3 mm
39 Ω/km
146 kg/km
6 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
16x0,75 mm²
11.3 mm
26 Ω/km
190 kg/km
13 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
16x1 mm²
12.4 mm
19.5 Ω/km
241 kg/km
16 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
16x1,5 mm²
14.3 mm
13.3 Ω/km
332 kg/km
20 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
16x2,5 mm²
16.6 mm
7.98 Ω/km
497 kg/km
25 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
18x0,5 mm²
10.8 mm
39 Ω/km
162 kg/km
6 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
18x0,75 mm²
12 mm
26 Ω/km
217 kg/km
13 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
18x1 mm²
13 mm
19.5 Ω/km
268 kg/km
16 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
18x1,5 mm²
15 mm
13.3 Ω/km
370 kg/km
20 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
18x2,5 mm²
17.5 mm
7.98 Ω/km
555 kg/km
25 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
20x0,5 mm²
11.4 mm
39 Ω/km
178 kg/km
6 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
20x0,75 mm²
12.7 mm
26 Ω/km
239 kg/km
13 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
20x1 mm²
13.7 mm
19.5 Ω/km
295 kg/km
16 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
20x1,5 mm²
16.1 mm
13.3 Ω/km
416 kg/km
20 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
20x2,5 mm²
18.5 mm
7.98 Ω/km
613 kg/km
25 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
24x0,5 mm²
12.4 mm
39 Ω/km
215 kg/km
6 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
24x0,75 mm²
13.6 mm
26 Ω/km
280 kg/km
13 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
24x1 mm²
14.7 mm
19.5 Ω/km
348 kg/km
16 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
24x1,5 mm²
17.2 mm
13.3 Ω/km
491 kg/km
20 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
24x2,5 mm²
19.9 mm
7.98 Ω/km
728 kg/km
25 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
25x0,5 mm²
12.7 mm
39 Ω/km
223 kg/km
6 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
25x0,75 mm²
13.9 mm
26 Ω/km
291 kg/km
13 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
25x1 mm²
15.1 mm
19.5 Ω/km
362 kg/km
16 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
25x1,5 mm²
17.7 mm
13.3 Ω/km
511 kg/km
20 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
25x2,5 mm²
20.4 mm
7.98 Ω/km
757 kg/km
25 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
2x0,5 mm²
5.3 mm
39 Ω/km
28 kg/km
6 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
2x0,75 mm²
5.7 mm
26 Ω/km
35 kg/km
13 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
2x1 mm²
6.1 mm
19.5 Ω/km
41 kg/km
16 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
2x1,5 mm²
7.1 mm
13.3 Ω/km
57 kg/km
20 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
2x2,5 mm²
8 mm
7.98 Ω/km
78 kg/km
25 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
3x0,5 mm²
5.6 mm
39 Ω/km
36 kg/km
6 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
3x0,75 mm²
6 mm
26 Ω/km
45 kg/km
13 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
3x1 mm²
6.7 mm
19.5 Ω/km
57 kg/km
16 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
3x1,5 mm²
7.5 mm
13.3 Ω/km
75 kg/km
20 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
3x2,5 mm²
8.5 mm
7.98 Ω/km
106 kg/km
25 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
4x0,5 mm²
6.1 mm
39 Ω/km
44 kg/km
6 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
4x0,75 mm²
6.7 mm
26 Ω/km
58 kg/km
13 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
4x1 mm²
7.2 mm
19.5 Ω/km
70 kg/km
16 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
4x1,5 mm²
8.2 mm
13.3 Ω/km
94 kg/km
20 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
4x2,5 mm²
9.5 mm
7.98 Ω/km
139 kg/km
25 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
5x0,5 mm²
6.7 mm
39 Ω/km
55 kg/km
6 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
5x0,75 mm²
7.3 mm
26 Ω/km
70 kg/km
13 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
5x1 mm²
7.8 mm
19.5 Ω/km
84 kg/km
16 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
5x1,5 mm²
9.1 mm
13.3 Ω/km
118 kg/km
20 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
5x2,5 mm²
10.3 mm
7.98 Ω/km
169 kg/km
25 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
6x0,5 mm²
7.2 mm
39 Ω/km
64 kg/km
6 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
6x0,75 mm²
7.8 mm
26 Ω/km
81 kg/km
13 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
6x1 mm²
8.4 mm
19.5 Ω/km
98 kg/km
16 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
6x1,5 mm²
9.8 mm
13.3 Ω/km
138 kg/km
20 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
6x2,5 mm²
11.2 mm
7.98 Ω/km
198 kg/km
25 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
7x0,5 mm²
7.2 mm
39 Ω/km
70 kg/km
6 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
7x0,75 mm²
7.8 mm
26 Ω/km
90 kg/km
13 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
7x1 mm²
8.4 mm
19.5 Ω/km
110 kg/km
16 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
7x1,5 mm²
9.8 mm
13.3 Ω/km
155 kg/km
20 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
7x2,5 mm²
11.2 mm
7.98 Ω/km
224 kg/km
25 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
8x0,5 mm²
8 mm
39 Ω/km
80 kg/km
6 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
8x0,75 mm²
8.7 mm
26 Ω/km
102 kg/km
13 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
8x1 mm²
9.6 mm
19.5 Ω/km
130 kg/km
16 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
8x1,5 mm²
11 mm
13.3 Ω/km
177 kg/km
20 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
8x2,5 mm²
12.7 mm
7.98 Ω/km
262 kg/km
25 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
9x0,5 mm²
8.6 mm
39 Ω/km
89 kg/km
6 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
9x0,75 mm²
9.6 mm
26 Ω/km
118 kg/km
13 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
9x1 mm²
10.3 mm
19.5 Ω/km
144 kg/km
16 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
9x1,5 mm²
12 mm
13.3 Ω/km
202 kg/km
20 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
9x2,5 mm²
13.8 mm
7.98 Ω/km
293 kg/km
25 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Glass Fiber
Tape
Glass Fiber
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
Title Type Language
LIHH FE180/PH120 Ürün Ana Görseli PNG
LIHH FE180/PH120 Ürün Kataloğu PDF
LIHH FE180/PH120 Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1