LIHCH-TP FE180/PH120

Signal Cables
These cables have low smoke density and are used in smart or semi-smart buildings, in enclosed spaces where people are densely populated or where valuable items are located, for controlling devices that need to operate during a fire, in industrial electronics, computers and office machines, internal communications, and internal sound systems, in places where the protection of human life and important materials is necessary.

Halogen Free
Technical Specifications
Product
0,5 mm²
7.5 mm
39 Ω/km
73 kg/km
6 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
8 mm
39 Ω/km
91 kg/km
6 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
8.9 mm
39 Ω/km
115 kg/km
6 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
9.8 mm
39 Ω/km
138 kg/km
6 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
8.4 mm
26 Ω/km
93 kg/km
13 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
9 mm
26 Ω/km
118 kg/km
13 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
9.9 mm
26 Ω/km
147 kg/km
13 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
10 mm
26 Ω/km
136 kg/km
13 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
11 mm
26 Ω/km
166 kg/km
13 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
11.1 mm
26 Ω/km
182 kg/km
13 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
12.2 mm
26 Ω/km
218 kg/km
13 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
15.8 mm
26 Ω/km
319 kg/km
13 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
9 mm
19.5 Ω/km
109 kg/km
16 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
9.6 mm
19.5 Ω/km
140 kg/km
16 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
10.6 mm
19.5 Ω/km
174 kg/km
16 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
11.8 mm
19.5 Ω/km
215 kg/km
16 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
10.7 mm
13.3 Ω/km
151 kg/km
20 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
11.5 mm
13.3 Ω/km
198 kg/km
20 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
12.7 mm
13.3 Ω/km
250 kg/km
20 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
12.8 mm
13.3 Ω/km
235 kg/km
20 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
14 mm
13.3 Ω/km
303 kg/km
20 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
14.1 mm
13.3 Ω/km
286 kg/km
20 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
15.5 mm
13.3 Ω/km
377 kg/km
20 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
20.1 mm
13.3 Ω/km
551 kg/km
20 A
Number of Pairs
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200