LIHCH FE180/PH120

Signal Cables
Used in areas with very high fire safety requirements, in automation and control systems, industrial electronics, in signal transmission, building communication systems, and security and fire alarm systems.

Halogen Free
Technical Specifications
Product
10x0,5 mm²
9.5 mm
39 Ω/km
112 kg/km
6 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
10x0,75 mm²
10.3 mm
26 Ω/km
142 kg/km
13 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
10x1 mm²
11.1 mm
19.5 Ω/km
172 kg/km
16 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
10x1,5 mm²
12.9 mm
13.3 Ω/km
238 kg/km
20 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
10x2,5 mm²
14.7 mm
7.98 Ω/km
340 kg/km
25 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
12x0,5 mm²
9.8 mm
39 Ω/km
127 kg/km
6 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
12x0,75 mm²
10.6 mm
26 Ω/km
162 kg/km
13 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
12x1 mm²
11.5 mm
19.5 Ω/km
198 kg/km
16 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
12x1,5 mm²
13.3 mm
13.3 Ω/km
274 kg/km
20 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
12x2,5 mm²
15.2 mm
7.98 Ω/km
396 kg/km
25 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
14x0,5 mm²
10.2 mm
39 Ω/km
144 kg/km
6 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
14x0,75 mm²
11.1 mm
26 Ω/km
183 kg/km
13 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
14x1 mm²
12.2 mm
19.5 Ω/km
230 kg/km
16 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
14x1,5 mm²
14 mm
13.3 Ω/km
313 kg/km
20 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
14x2,5 mm²
16 mm
7.98 Ω/km
453 kg/km
25 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
16x0,5 mm²
10.7 mm
39 Ω/km
160 kg/km
6 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
16x0,75 mm²
11.7 mm
26 Ω/km
205 kg/km
13 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
16x1 mm²
12.8 mm
19.5 Ω/km
257 kg/km
16 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
16x1,5 mm²
14.7 mm
13.3 Ω/km
351 kg/km
20 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
16x2,5 mm²
17 mm
7.98 Ω/km
519 kg/km
25 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
18x0,5 mm²
11.2 mm
39 Ω/km
176 kg/km
6 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
18x0,75 mm²
12.4 mm
26 Ω/km
232 kg/km
13 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
18x1 mm²
13.4 mm
19.5 Ω/km
285 kg/km
16 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
18x1,5 mm²
15.4 mm
13.3 Ω/km
389 kg/km
20 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
18x2,5 mm²
17.9 mm
7.98 Ω/km
578 kg/km
25 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
20x0,5 mm²
11.8 mm
39 Ω/km
193 kg/km
6 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
20x0,75 mm²
13.1 mm
26 Ω/km
255 kg/km
13 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
20x1 mm²
14.1 mm
19.5 Ω/km
313 kg/km
16 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
20x1,5 mm²
16.5 mm
13.3 Ω/km
437 kg/km
20 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
20x2,5 mm²
18.9 mm
7.98 Ω/km
638 kg/km
25 A
Number of Cores
20 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
24x0,5 mm²
12.8 mm
39 Ω/km
231 kg/km
6 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
24x0,75 mm²
14 mm
26 Ω/km
298 kg/km
13 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
24x1 mm²
15.1 mm
19.5 Ω/km
367 kg/km
16 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
24x1,5 mm²
17.6 mm
13.3 Ω/km
514 kg/km
20 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
24x2,5 mm²
20.3 mm
7.98 Ω/km
753 kg/km
25 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
25x0,5 mm²
13.1 mm
39 Ω/km
240 kg/km
6 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
25x0,75 mm²
14.3 mm
26 Ω/km
309 kg/km
13 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
25x1 mm²
15.5 mm
19.5 Ω/km
381 kg/km
16 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
25x1,5 mm²
18.1 mm
13.3 Ω/km
535 kg/km
20 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
25x2,5 mm²
20.8 mm
7.98 Ω/km
784 kg/km
25 A
Number of Cores
25 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
2x0,5 mm²
5.7 mm
39 Ω/km
35 kg/km
6 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
2x0,75 mm²
6.1 mm
26 Ω/km
42 kg/km
13 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
2x1 mm²
6.5 mm
19.5 Ω/km
48 kg/km
16 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
2x1,5 mm²
7.5 mm
13.3 Ω/km
66 kg/km
20 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
2x2,5 mm²
8.4 mm
7.98 Ω/km
89 kg/km
25 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
3x0,5 mm²
6 mm
39 Ω/km
44 kg/km
6 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
3x0,75 mm²
6.4 mm
26 Ω/km
52 kg/km
13 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
3x1 mm²
7.1 mm
19.5 Ω/km
66 kg/km
16 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
3x1,5 mm²
7.9 mm
13.3 Ω/km
85 kg/km
20 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
3x2,5 mm²
8.9 mm
7.98 Ω/km
117 kg/km
25 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
4x0,5 mm²
6.5 mm
39 Ω/km
52 kg/km
6 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
4x0,75 mm²
7.1 mm
26 Ω/km
67 kg/km
13 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
4x1 mm²
7.6 mm
19.5 Ω/km
80 kg/km
16 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
4x1,5 mm²
8.6 mm
13.3 Ω/km
105 kg/km
20 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
4x2,5 mm²
9.9 mm
7.98 Ω/km
151 kg/km
25 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
5x0,5 mm²
7.1 mm
39 Ω/km
64 kg/km
6 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
5x0,75 mm²
7.7 mm
26 Ω/km
80 kg/km
13 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
5x1 mm²
8.2 mm
19.5 Ω/km
94 kg/km
16 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
5x1,5 mm²
9.5 mm
13.3 Ω/km
130 kg/km
20 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
5x2,5 mm²
10.7 mm
7.98 Ω/km
182 kg/km
25 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
6x0,5 mm²
7.6 mm
39 Ω/km
73 kg/km
6 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
6x0,75 mm²
8.2 mm
26 Ω/km
91 kg/km
13 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
6x1 mm²
8.8 mm
19.5 Ω/km
109 kg/km
16 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
6x1,5 mm²
10.2 mm
13.3 Ω/km
151 kg/km
20 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
6x2,5 mm²
11.6 mm
7.98 Ω/km
213 kg/km
25 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
7x0,5 mm²
7.6 mm
39 Ω/km
80 kg/km
6 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
7x0,75 mm²
8.2 mm
26 Ω/km
100 kg/km
13 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
7x1 mm²
8.8 mm
19.5 Ω/km
120 kg/km
16 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
7x1,5 mm²
10.2 mm
13.3 Ω/km
167 kg/km
20 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
7x2,5 mm²
11.6 mm
7.98 Ω/km
239 kg/km
25 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
8x0,5 mm²
8.4 mm
39 Ω/km
90 kg/km
6 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
8x0,75 mm²
9.1 mm
26 Ω/km
113 kg/km
13 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
8x1 mm²
10 mm
19.5 Ω/km
142 kg/km
16 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
8x1,5 mm²
11.4 mm
13.3 Ω/km
191 kg/km
20 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
8x2,5 mm²
13.1 mm
7.98 Ω/km
278 kg/km
25 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
9x0,5 mm²
9 mm
39 Ω/km
100 kg/km
6 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
9x0,75 mm²
10 mm
26 Ω/km
130 kg/km
13 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
9x1 mm²
10.7 mm
19.5 Ω/km
158 kg/km
16 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
9x1,5 mm²
12.4 mm
13.3 Ω/km
218 kg/km
20 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
9x2,5 mm²
14.2 mm
7.98 Ω/km
311 kg/km
25 A
Number of Cores
9 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Braid
Tape
Polyester & Glass Fiber
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
Title Type Language
LIHCH FE180/PH120 Ürün Ana Görseli PNG
LIHCH FE180/PH120 Ürün Kataloğu PDF
LIHCH FE180/PH120 Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1