LIH(St)H-TP FE180/PH120

Signal Cables
These cables have low smoke density and are used in smart or semi-smart buildings, in enclosed spaces where people are densely populated or where valuable items are located, for controlling devices that need to operate during a fire, in industrial electronics, computers and office machines, internal communications, and internal sound systems, in places where the protection of human life and important materials is necessary.

Halogen Free
Technical Specifications
Product
0,5 mm²
7.1 mm
39 Ω/km
61 kg/km
6 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
7.6 mm
39 Ω/km
80 kg/km
6 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
8.4 mm
39 Ω/km
99 kg/km
6 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
9.3 mm
39 Ω/km
121 kg/km
6 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,5 mm²
10.4 mm
39 Ω/km
159 kg/km
6 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
8 mm
26 Ω/km
81 kg/km
13 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
8.6 mm
26 Ω/km
105 kg/km
13 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
9.6 mm
26 Ω/km
135 kg/km
13 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
10.6 mm
26 Ω/km
164 kg/km
13 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
0,75 mm²
11.8 mm
26 Ω/km
197 kg/km
13 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
8.5 mm
19.5 Ω/km
95 kg/km
16 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
9.2 mm
19.5 Ω/km
126 kg/km
16 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
10.1 mm
19.5 Ω/km
157 kg/km
16 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
11.3 mm
19.5 Ω/km
196 kg/km
16 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1 mm²
12.5 mm
19.5 Ω/km
258 kg/km
16 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
10.3 mm
13.3 Ω/km
138 kg/km
20 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
11.1 mm
13.3 Ω/km
183 kg/km
20 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
12.4 mm
13.3 Ω/km
233 kg/km
20 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
13.7 mm
13.3 Ω/km
283 kg/km
20 A
Number of Pairs
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
1,5 mm²
15 mm
13.3 Ω/km
369 kg/km
20 A
Number of Pairs
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Mutual Capacitance
120 pF/m
Current Type
DC
Layer Structure
Polyester Tape, Glass Fiber, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Glass Fiber & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-40 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Resistance to Fire with Mechanical Shock
IEC 60331-23;EN 50200
Title Type Language
LIH(St)H-TP FE180/PH120 Ürün Ana Görseli PNG
LIH(St)H-TP FE180/PH120 Ürün Kataloğu PDF
LIH(St)H-TP FE180/PH120 Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1