LIH(St)H PiMF

Signal Cables
Used in densely populated indoor environments, requiring protection against electromagnetic interference (EMI) in automation and control systems, industrial electronic applications, computers, office machines, internal communication systems, and sound systems, where human life, valuable materials, and equipment need to be protected.

Halogen Free
Technical Specifications
Product
0,22 mm²
6.4 mm
79 Ω/km
55 kg/km
2.5 A
Number of Pairs
2 Piece
Operating Voltage (DC)
250 VDC
Test Voltage (DC)
1500 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,22 mm²
6.9 mm
79 Ω/km
70 kg/km
2.5 A
Number of Pairs
3 Piece
Operating Voltage (DC)
250 VDC
Test Voltage (DC)
1500 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,22 mm²
7.3 mm
79 Ω/km
85 kg/km
2.5 A
Number of Pairs
4 Piece
Operating Voltage (DC)
250 VDC
Test Voltage (DC)
1500 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,22 mm²
10.1 mm
79 Ω/km
130 kg/km
2.5 A
Number of Pairs
8 Piece
Operating Voltage (DC)
250 VDC
Test Voltage (DC)
1500 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,22 mm²
12.8 mm
79 Ω/km
190 kg/km
2.5 A
Number of Pairs
12 Piece
Operating Voltage (DC)
250 VDC
Test Voltage (DC)
1500 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,34 mm²
6.6 mm
56 Ω/km
75 kg/km
4.5 A
Number of Pairs
2 Piece
Operating Voltage (DC)
250 VDC
Test Voltage (DC)
1500 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,34 mm²
7.2 mm
56 Ω/km
105 kg/km
4.5 A
Number of Pairs
3 Piece
Operating Voltage (DC)
250 VDC
Test Voltage (DC)
1500 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,34 mm²
7.8 mm
56 Ω/km
120 kg/km
4.5 A
Number of Pairs
4 Piece
Operating Voltage (DC)
250 VDC
Test Voltage (DC)
1500 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,34 mm²
10.4 mm
56 Ω/km
200 kg/km
4.5 A
Number of Pairs
8 Piece
Operating Voltage (DC)
250 VDC
Test Voltage (DC)
1500 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,34 mm²
14 mm
56 Ω/km
285 kg/km
4.5 A
Number of Pairs
12 Piece
Operating Voltage (DC)
250 VDC
Test Voltage (DC)
1500 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,5 mm²
7.5 mm
39 Ω/km
95 kg/km
6 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,5 mm²
8.2 mm
39 Ω/km
130 kg/km
6 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,5 mm²
9 mm
39 Ω/km
145 kg/km
6 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,5 mm²
11.4 mm
39 Ω/km
255 kg/km
6 A
Number of Pairs
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,5 mm²
15.1 mm
39 Ω/km
360 kg/km
6 A
Number of Pairs
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,75 mm²
8.4 mm
26 Ω/km
115 kg/km
13 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,75 mm²
9.3 mm
26 Ω/km
145 kg/km
13 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,75 mm²
10.5 mm
26 Ω/km
185 kg/km
13 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,75 mm²
13.8 mm
26 Ω/km
290 kg/km
13 A
Number of Pairs
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
0,75 mm²
18.2 mm
26 Ω/km
380 kg/km
13 A
Number of Pairs
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
1 mm²
9.6 mm
19.5 Ω/km
145 kg/km
16 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
1 mm²
10.2 mm
19.5 Ω/km
190 kg/km
16 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
1 mm²
11.8 mm
19.5 Ω/km
285 kg/km
16 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
1 mm²
14.1 mm
19.5 Ω/km
395 kg/km
16 A
Number of Pairs
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
1 mm²
17.6 mm
19.5 Ω/km
570 kg/km
16 A
Number of Pairs
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
1,5 mm²
10.9 mm
13.3 Ω/km
185 kg/km
20 A
Number of Pairs
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
1,5 mm²
11.8 mm
13.3 Ω/km
285 kg/km
20 A
Number of Pairs
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
1,5 mm²
13.1 mm
13.3 Ω/km
350 kg/km
20 A
Number of Pairs
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
1,5 mm²
17.2 mm
13.3 Ω/km
550 kg/km
20 A
Number of Pairs
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
1,5 mm²
21 mm
13.3 Ω/km
705 kg/km
20 A
Number of Pairs
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Polyester Tape, Tinned Copper Ground Wire, Al/Pet Tape
Tape
Polyester & Aluminum/Pet
Drain Wire
Tinned Copper
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Title Type Language
LIH(St)H PiMF Ürün Ana Görseli PNG
LIH(St)H PiMF Ürün Kataloğu PDF
LIH(St)H PiMF Ürün Kesit Görseli JPG
How can we help you?