HSLH 0.6/1 kV

Control Cables
Used in areas with very high fire safety requirements, in automation and control systems, at power stations, for measuring and control purposes in machine manufacturing, assembly lines, and production lines, where there are moderate mechanical stresses.

Halogen Free
Technical Specifications
Product
10x1 mm²
14.1 mm
19.5 Ω/km
288 kg/km
16 A
Number of Cores
10 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
10x1,5 mm²
14.8 mm
13.3 Ω/km
339 kg/km
20 A
Number of Cores
10 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
10x2,5 mm²
16.4 mm
7.98 Ω/km
457 kg/km
25 A
Number of Cores
10 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
12x1 mm²
15 mm
19.5 Ω/km
329 kg/km
16 A
Number of Cores
12 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
12x1,5 mm²
15.7 mm
13.3 Ω/km
392 kg/km
20 A
Number of Cores
12 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
12x2,5 mm²
17.5 mm
7.98 Ω/km
530 kg/km
25 A
Number of Cores
12 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
14x1 mm²
15.9 mm
19.5 Ω/km
371 kg/km
16 A
Number of Cores
14 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
14x1,5 mm²
16.7 mm
13.3 Ω/km
442 kg/km
20 A
Number of Cores
14 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
14x2,5 mm²
18.6 mm
7.98 Ω/km
604 kg/km
25 A
Number of Cores
14 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
16x1 mm²
16.8 mm
19.5 Ω/km
418 kg/km
16 A
Number of Cores
16 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
16x1,5 mm²
17.7 mm
13.3 Ω/km
500 kg/km
20 A
Number of Cores
16 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
16x2,5 mm²
19.7 mm
7.98 Ω/km
688 kg/km
25 A
Number of Cores
16 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
18x1 mm²
17.7 mm
19.5 Ω/km
466 kg/km
16 A
Number of Cores
18 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
18x1,5 mm²
18.7 mm
13.3 Ω/km
560 kg/km
20 A
Number of Cores
18 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
18x2,5 mm²
20.9 mm
7.98 Ω/km
769 kg/km
25 A
Number of Cores
18 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
20x1 mm²
18.6 mm
19.5 Ω/km
515 kg/km
16 A
Number of Cores
20 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
20x1,5 mm²
19.6 mm
13.3 Ω/km
618 kg/km
20 A
Number of Cores
20 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
20x2,5 mm²
22 mm
7.98 Ω/km
853 kg/km
25 A
Number of Cores
20 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
24x1 mm²
19.5 mm
19.5 Ω/km
575 kg/km
16 A
Number of Cores
24 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
24x1,5 mm²
20.6 mm
13.3 Ω/km
695 kg/km
20 A
Number of Cores
24 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
24x2,5 mm²
23.1 mm
7.98 Ω/km
966 kg/km
25 A
Number of Cores
24 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
25x1 mm²
20.5 mm
19.5 Ω/km
624 kg/km
16 A
Number of Cores
25 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
25x1,5 mm²
21.6 mm
13.3 Ω/km
750 kg/km
20 A
Number of Cores
25 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
25x2,5 mm²
24.2 mm
7.98 Ω/km
1038 kg/km
25 A
Number of Cores
25 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
2x1 mm²
9.4 mm
19.5 Ω/km
116 kg/km
16 A
Number of Cores
2 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
2x1,5 mm²
9.8 mm
13.3 Ω/km
131 kg/km
20 A
Number of Cores
2 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
2x2,5 mm²
10.7 mm
7.98 Ω/km
165 kg/km
25 A
Number of Cores
2 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
3x1 mm²
9.9 mm
19.5 Ω/km
133 kg/km
16 A
Number of Cores
3 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
3x1,5 mm²
10.3 mm
13.3 Ω/km
152 kg/km
20 A
Number of Cores
3 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
3x2,5 mm²
11.3 mm
7.98 Ω/km
195 kg/km
25 A
Number of Cores
3 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
4x1 mm²
10.6 mm
19.5 Ω/km
156 kg/km
16 A
Number of Cores
4 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
4x1,5 mm²
11.1 mm
13.3 Ω/km
182 kg/km
20 A
Number of Cores
4 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
4x2,5 mm²
12.2 mm
7.98 Ω/km
235 kg/km
25 A
Number of Cores
4 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
5x1 mm²
11.4 mm
19.5 Ω/km
185 kg/km
16 A
Number of Cores
5 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
5x1,5 mm²
12 mm
13.3 Ω/km
213 kg/km
20 A
Number of Cores
5 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
5x2,5 mm²
13.2 mm
7.98 Ω/km
280 kg/km
25 A
Number of Cores
5 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
6x1 mm²
12.3 mm
19.5 Ω/km
213 kg/km
16 A
Number of Cores
6 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
6x1,5 mm²
12.9 mm
13.3 Ω/km
248 kg/km
20 A
Number of Cores
6 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
6x2,5 mm²
14.2 mm
7.98 Ω/km
329 kg/km
25 A
Number of Cores
6 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
7x1 mm²
12.3 mm
19.5 Ω/km
220 kg/km
16 A
Number of Cores
7 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
7x1,5 mm²
12.9 mm
13.3 Ω/km
258 kg/km
20 A
Number of Cores
7 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
7x2,5 mm²
14.2 mm
7.98 Ω/km
345 kg/km
25 A
Number of Cores
7 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
8x1 mm²
14.1 mm
19.5 Ω/km
292 kg/km
16 A
Number of Cores
8 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
8x1,5 mm²
14.8 mm
13.3 Ω/km
341 kg/km
20 A
Number of Cores
8 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
8x2,5 mm²
16.4 mm
7.98 Ω/km
453 kg/km
25 A
Number of Cores
8 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
9x1 mm²
15 mm
19.5 Ω/km
329 kg/km
16 A
Number of Cores
9 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
9x1,5 mm²
15.7 mm
13.3 Ω/km
386 kg/km
20 A
Number of Cores
9 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
9x2,5 mm²
17.5 mm
7.98 Ω/km
512 kg/km
25 A
Number of Cores
9 Piece
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (DC)
4000 VDC
Current Type
DC
Minimum Bending Radius
10 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Flame Propagation Test
TS EN IEC 60332-3-24
Smoke Density Test
EN 61034-2
Corrosive Gas Test
EN 60754-2
Halogen Free Test
EN 60754-1
Title Type Language
HSLH 0.6/1 kV Ürün Ana Görseli PNG
HSLH 0.6/1 kV Ürün Kataloğu PDF
HSLH 0.6/1 kV Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1