H05VVC4V5-K (NYSLYCYö)

Control Cables
Used in areas requiring protection against electromagnetic interference (EMI), at fuel pumps, in automation and control systems, and for measurement and control in machine manufacturing, assembly and production lines, in wet, dry, and humid environments, where chemical resistance is required, and where mechanical stress is moderate.

Technical Specifications
Product
10x0,5 mm²
12.8 mm
39 Ω/km
206 kg/km
6 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
10x0,75 mm²
14.6 mm
26 Ω/km
264 kg/km
13 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
10x1 mm²
16.2 mm
19.5 Ω/km
326 kg/km
16 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
10x1,5 mm²
17.2 mm
13.3 Ω/km
385 kg/km
20 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
10x2,5 mm²
20.8 mm
7.98 Ω/km
560 kg/km
25 A
Number of Cores
10 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
12x0,5 mm²
14.2 mm
39 Ω/km
238 kg/km
6 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
12x0,75 mm²
15.4 mm
26 Ω/km
303 kg/km
13 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
12x1 mm²
17.2 mm
19.5 Ω/km
370 kg/km
16 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
12x1,5 mm²
18.6 mm
13.3 Ω/km
451 kg/km
20 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
12x2,5 mm²
22.4 mm
7.98 Ω/km
657 kg/km
25 A
Number of Cores
12 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
14x0,5 mm²
14.8 mm
39 Ω/km
259 kg/km
6 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
14x0,75 mm²
16.4 mm
26 Ω/km
342 kg/km
13 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
14x1 mm²
18 mm
19.5 Ω/km
424 kg/km
16 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
14x1,5 mm²
19.4 mm
13.3 Ω/km
509 kg/km
20 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
14x2,5 mm²
23.6 mm
7.98 Ω/km
750 kg/km
25 A
Number of Cores
14 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
16x0,5 mm²
15.2 mm
39 Ω/km
283 kg/km
6 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
16x0,75 mm²
17.2 mm
26 Ω/km
386 kg/km
13 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
16x1 mm²
19 mm
19.5 Ω/km
468 kg/km
16 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
16x1,5 mm²
20.2 mm
13.3 Ω/km
582 kg/km
20 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
16x2,5 mm²
24.8 mm
7.98 Ω/km
825 kg/km
25 A
Number of Cores
16 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
18x0,5 mm²
16 mm
39 Ω/km
320 kg/km
6 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
18x0,75 mm²
18.2 mm
26 Ω/km
408 kg/km
13 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
18x1 mm²
19.4 mm
19.5 Ω/km
513 kg/km
16 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
18x1,5 mm²
21.5 mm
13.3 Ω/km
637 kg/km
20 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
18x2,5 mm²
25.9 mm
7.98 Ω/km
936 kg/km
25 A
Number of Cores
18 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
24x0,5 mm²
17.6 mm
39 Ω/km
409 kg/km
6 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
24x0,75 mm²
20.6 mm
26 Ω/km
567 kg/km
13 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
24x1 mm²
22.3 mm
19.5 Ω/km
653 kg/km
16 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
24x1,5 mm²
25 mm
13.3 Ω/km
836 kg/km
20 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
24x2,5 mm²
27.8 mm
7.98 Ω/km
1375 kg/km
25 A
Number of Cores
24 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
2x0,5 mm²
8.5 mm
39 Ω/km
80 kg/km
6 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
2x0,75 mm²
9.2 mm
26 Ω/km
95 kg/km
13 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
2x1 mm²
9.4 mm
19.5 Ω/km
117 kg/km
16 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
2x1,5 mm²
10.2 mm
13.3 Ω/km
129 kg/km
20 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
2x2,5 mm²
11.9 mm
7.98 Ω/km
192 kg/km
25 A
Number of Cores
2 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
3x0,5 mm²
8.8 mm
39 Ω/km
96 kg/km
6 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
3x0,75 mm²
9.4 mm
26 Ω/km
114 kg/km
13 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
3x1 mm²
10.3 mm
19.5 Ω/km
146 kg/km
16 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
3x1,5 mm²
11 mm
13.3 Ω/km
160 kg/km
20 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
3x2,5 mm²
13.2 mm
7.98 Ω/km
213 kg/km
25 A
Number of Cores
3 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
4x0,5 mm²
9.6 mm
39 Ω/km
110 kg/km
6 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
4x0,75 mm²
10.4 mm
26 Ω/km
125 kg/km
13 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
4x1 mm²
10.9 mm
19.5 Ω/km
163 kg/km
16 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
4x1,5 mm²
12.4 mm
13.3 Ω/km
196 kg/km
20 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
4x2,5 mm²
14.4 mm
7.98 Ω/km
269 kg/km
25 A
Number of Cores
4 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
5x0,5 mm²
10 mm
39 Ω/km
130 kg/km
6 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
5x0,75 mm²
11.1 mm
26 Ω/km
150 kg/km
13 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
5x1 mm²
11.8 mm
19.5 Ω/km
189 kg/km
16 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
5x1,5 mm²
13 mm
13.3 Ω/km
209 kg/km
20 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
5x2,5 mm²
15.6 mm
7.98 Ω/km
328 kg/km
25 A
Number of Cores
5 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
6x0,5 mm²
11.2 mm
39 Ω/km
147 kg/km
6 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
6x0,75 mm²
12 mm
26 Ω/km
178 kg/km
13 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
6x1 mm²
12.6 mm
19.5 Ω/km
214 kg/km
16 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
6x1,5 mm²
14.3 mm
13.3 Ω/km
255 kg/km
20 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
6x2,5 mm²
16.8 mm
7.98 Ω/km
377 kg/km
25 A
Number of Cores
6 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
7x0,5 mm²
11.2 mm
39 Ω/km
155 kg/km
6 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
7x0,75 mm²
12 mm
26 Ω/km
191 kg/km
13 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
7x1 mm²
12.6 mm
19.5 Ω/km
259 kg/km
16 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
7x1,5 mm²
14.3 mm
13.3 Ω/km
309 kg/km
20 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
7x2,5 mm²
16.8 mm
7.98 Ω/km
419 kg/km
25 A
Number of Cores
7 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
8x0,5 mm²
12 mm
39 Ω/km
171 kg/km
6 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
8x0,75 mm²
13.2 mm
26 Ω/km
216 kg/km
13 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
8x1 mm²
14.8 mm
19.5 Ω/km
286 kg/km
16 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
8x1,5 mm²
16.2 mm
13.3 Ω/km
337 kg/km
20 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
8x2,5 mm²
19 mm
7.98 Ω/km
473 kg/km
25 A
Number of Cores
8 Piece
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (DC)
2000 VDC
Current Type
DC
Layer Structure
Tinned Copper Braid
Braiding
Tinned Copper
Minimum Bending Radius
7.5 x D mm
Temperature Range
-30 - +70 °C
Flame Retardant Test
EN 60332-1-2
Chemical Resistance
IEC 60811-404
Title Type Language
H05VVC4V5-K (NYSLYCYö) Ürün Ana Görseli PNG
H05VVC4V5-K (NYSLYCYö) Ürün Kataloğu PDF
H05VVC4V5-K (NYSLYCYö) Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1