YVZ3V / NYFGbY

PVC Insulated Power Cables with Flat Steel Wire Armour
Suitable for heavy-duty conditions where protection against external effects and mechanical strength are important. Thanks to its armored structure, it is resistant to impacts from outside. Resistant to sudden and short-term increases in working temperature. Used as a network and lighting cable, in cable ducts, under plaster, and underground.

Twisted
Technical Specifications
Product
2x10 mm²
20.74 mm
1.83 Ω/km
918.5 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x16 mm²
22.67 mm
1.15 Ω/km
1124.3 kg/km
A
Current Carrying Capacity in Air
89 A
Current Carrying Capacity in Ground
116 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x25 mm²
26.14 mm
0.727 Ω/km
1522.6 kg/km
A
Current Carrying Capacity in Air
118 A
Current Carrying Capacity in Ground
150 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x35 mm²
28.08 mm
0.524 Ω/km
1837.4 kg/km
A
Current Carrying Capacity in Air
145 A
Current Carrying Capacity in Ground
181 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x10 mm²
21.76 mm
1.83 Ω/km
1058.7 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x120 mm²
45.11 mm
0.153 Ω/km
5655.2 kg/km
A
Current Carrying Capacity in Air
282 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x120+70 mm²
47.4 mm
0,153 / 0,268 Ω/km
6375.2 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
318 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x150 mm²
49.59 mm
0.124 Ω/km
6805.4 kg/km
A
Current Carrying Capacity in Air
324 A
Current Carrying Capacity in Ground
353 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x150+70 mm²
51.22 mm
0,124 / 0,268 Ω/km
7468.9 kg/km
A
Current Carrying Capacity in Air
326 A
Current Carrying Capacity in Ground
359 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x16 mm²
23.8 mm
1.15 Ω/km
1314.4 kg/km
A
Current Carrying Capacity in Air
80 A
Current Carrying Capacity in Ground
98 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x16+10 mm²
25.02 mm
1,15 / 1,83 Ω/km
1461.5 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x185 mm²
54.5 mm
0.0991 Ω/km
8303.7 kg/km
A
Current Carrying Capacity in Air
371 A
Current Carrying Capacity in Ground
399 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x185+95 mm²
57.12 mm
0,0991 / 0,193 Ω/km
9305.1 kg/km
A
Current Carrying Capacity in Air
374 A
Current Carrying Capacity in Ground
406 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x240 mm²
61.37 mm
0.0754 Ω/km
10585.8 kg/km
A
Current Carrying Capacity in Air
436 A
Current Carrying Capacity in Ground
464 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x240+120 mm²
63.34 mm
0,754 / 0,153 Ω/km
11737.5 kg/km
A
Current Carrying Capacity in Air
445 A
Current Carrying Capacity in Ground
473 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x25 mm²
27.65 mm
0.727 Ω/km
1805.2 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
128 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x25+16 mm²
28.96 mm
0,727 / 1,15 Ω/km
2007.3 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x35 mm²
29.72 mm
0.524 Ω/km
2204 kg/km
A
Current Carrying Capacity in Air
131 A
Current Carrying Capacity in Ground
157 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x35+16 mm²
30.7 mm
0,524 / 1,15 Ω/km
2361.8 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x50 mm²
33.54 mm
0.387 Ω/km
2783.8 kg/km
A
Current Carrying Capacity in Air
159 A
Current Carrying Capacity in Ground
185 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x50+25 mm²
34.96 mm
0,387 / 0,727 Ω/km
3069.8 kg/km
A
Current Carrying Capacity in Air
157 A
Current Carrying Capacity in Ground
188 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x70 mm²
37.36 mm
0.268 Ω/km
3639 kg/km
A
Current Carrying Capacity in Air
202 A
Current Carrying Capacity in Ground
228 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x70+35 mm²
38.78 mm
0,268 / 0,524 Ω/km
4005.2 kg/km
A
Current Carrying Capacity in Air
199 A
Current Carrying Capacity in Ground
232 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x95 mm²
42.27 mm
0.198 Ω/km
4767.7 kg/km
A
Current Carrying Capacity in Air
244 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x95+50 mm²
44.02 mm
0,193 / 0,387 Ω/km
5263.7 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x10 mm²
23.29 mm
1.83 Ω/km
1222.3 kg/km
A
Current Carrying Capacity in Air
60 A
Current Carrying Capacity in Ground
75 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x120 mm²
49.59 mm
0.153 Ω/km
7005.7 kg/km
A
Current Carrying Capacity in Air
282 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x150 mm²
54.61 mm
0.124 Ω/km
8472.9 kg/km
A
Current Carrying Capacity in Air
324 A
Current Carrying Capacity in Ground
353 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x16 mm²
25.63 mm
1.15 Ω/km
1566.9 kg/km
A
Current Carrying Capacity in Air
80 A
Current Carrying Capacity in Ground
98 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x185 mm²
60.61 mm
0.0991 Ω/km
10427.6 kg/km
A
Current Carrying Capacity in Air
375 A
Current Carrying Capacity in Ground
391 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x240 mm²
67.7 mm
0.0754 Ω/km
13251 kg/km
A
Current Carrying Capacity in Air
436 A
Current Carrying Capacity in Ground
464 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x25 mm²
30.05 mm
0.727 Ω/km
2167.9 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
128 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x35 mm²
32.45 mm
0.524 Ω/km
2668.6 kg/km
A
Current Carrying Capacity in Air
131 A
Current Carrying Capacity in Ground
157 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x50 mm²
36.6 mm
0.387 Ω/km
3399.2 kg/km
A
Current Carrying Capacity in Air
159 A
Current Carrying Capacity in Ground
185 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x70 mm²
40.85 mm
0.268 Ω/km
4466.9 kg/km
A
Current Carrying Capacity in Air
202 A
Current Carrying Capacity in Ground
228 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x95 mm²
46.42 mm
0.193 Ω/km
5880.6 kg/km
A
Current Carrying Capacity in Air
244 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x10 mm²
24.92 mm
1.83 Ω/km
1389.6 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x120 mm²
54.39 mm
0.153 Ω/km
8388.7 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
318 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x150 mm²
60.5 mm
0.124 Ω/km
10253.2 kg/km
A
Current Carrying Capacity in Air
326 A
Current Carrying Capacity in Ground
359 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x16 mm²
27.65 mm
1.15 Ω/km
1802.9 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x185 mm²
66.61 mm
0.0991 Ω/km
12533.3 kg/km
A
Current Carrying Capacity in Air
374 A
Current Carrying Capacity in Ground
406 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x240 mm²
74.58 mm
0.0754 Ω/km
15992.6 kg/km
A
Current Carrying Capacity in Air
445 A
Current Carrying Capacity in Ground
473 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x25 mm²
32.67 mm
0.727 Ω/km
2544.8 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x35 mm²
35.29 mm
0.524 Ω/km
3139.8 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x50 mm²
39.98 mm
0.387 Ω/km
4014.7 kg/km
A
Current Carrying Capacity in Air
157 A
Current Carrying Capacity in Ground
188 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x70 mm²
44.67 mm
0.268 Ω/km
5296.8 kg/km
A
Current Carrying Capacity in Air
199 A
Current Carrying Capacity in Ground
232 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x95 mm²
50.89 mm
0.193 Ω/km
7024.9 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Flat Steel Wire Armor / Steel Tape
Armour
Yassı Çelik Tel
Tape
Galvanized Steel Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Title Type Language
YVZ3V / NYFGbY CE Kalite Sertifikası PDF
YVZ3V / NYFGbY DOP Kalite Sertifikası PDF
YVZ3V / NYFGbY TSE Kalite Sertifikası PDF
YVZ3V / NYFGbY Ürün Ana Görseli PNG
YVZ3V / NYFGbY Ürün Kataloğu PDF
YVZ3V / NYFGbY Ürün Kataloğu PDF
YVZ3V / NYFGbY Ürün Kesit Görseli JPG