PVC Insulated Power Cables with Concentric Copper Wire Screen
These cables with very low insulation losses are usually used underground. Connected to a concentric conductor protection switch and/or relay, they allow monitoring of impacts coming from outside to the cable. Used in power facilities where sudden load changes occur.


Solid
Technical Specifications
Product
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
32 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
66 A
Current Carrying Capacity in Ground
90 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
89 A
Current Carrying Capacity in Ground
116 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
27 A
Current Carrying Capacity in Ground
42 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
118 A
Current Carrying Capacity in Ground
150 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
145 A
Current Carrying Capacity in Ground
181 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
37 A
Current Carrying Capacity in Ground
54 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
48 A
Current Carrying Capacity in Ground
68 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
19 A
Current Carrying Capacity in Ground
26 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
60 A
Current Carrying Capacity in Ground
75 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
282 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
324 A
Current Carrying Capacity in Ground
353 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
80 A
Current Carrying Capacity in Ground
98 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
371 A
Current Carrying Capacity in Ground
399 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
35 A
Current Carrying Capacity in Ground
34 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
436 A
Current Carrying Capacity in Ground
464 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
128 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
481 A
Current Carrying Capacity in Ground
524 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
131 A
Current Carrying Capacity in Ground
157 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
44 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
159 A
Current Carrying Capacity in Ground
185 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
43 A
Current Carrying Capacity in Ground
56 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
202 A
Current Carrying Capacity in Ground
228 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
244 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
19 A
Current Carrying Capacity in Ground
26 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
60 A
Current Carrying Capacity in Ground
75 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
282 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
324 A
Current Carrying Capacity in Ground
353 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
80 A
Current Carrying Capacity in Ground
98 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
371 A
Current Carrying Capacity in Ground
399 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
34 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
436 A
Current Carrying Capacity in Ground
464 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
128 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
481 A
Current Carrying Capacity in Ground
524 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
131 A
Current Carrying Capacity in Ground
157 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
44 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
159 A
Current Carrying Capacity in Ground
185 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
43 A
Current Carrying Capacity in Ground
56 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
202 A
Current Carrying Capacity in Ground
228 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
244 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
19 A
Current Carrying Capacity in Ground
26 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
60 A
Current Carrying Capacity in Ground
75 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
282 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
324 A
Current Carrying Capacity in Ground
353 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
80 A
Current Carrying Capacity in Ground
98 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
371 A
Current Carrying Capacity in Ground
399 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
34 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
436 A
Current Carrying Capacity in Ground
464 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
128 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
481 A
Current Carrying Capacity in Ground
524 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
131 A
Current Carrying Capacity in Ground
157 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
44 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
159 A
Current Carrying Capacity in Ground
185 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
43 A
Current Carrying Capacity in Ground
56 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
202 A
Current Carrying Capacity in Ground
228 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
244 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, Polyester Film Tape
Tape
Concentric Copper Wire & Copper Tape & Polyester Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1