Technical Specifications
Product
2x1 mm²
4,10 x 6,40 mm
18.1 Ω/km
48.88 kg/km
A
Current Carrying Capacity in Air
13 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
2x1,5 mm²
4,55 x 7,30 mm
12.1 Ω/km
65.63 kg/km
A
Current Carrying Capacity in Air
16 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
2x10 mm²
8,2 x 14 mm
1.83 Ω/km
136.77 kg/km
A
Current Carrying Capacity in Air
53 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
2x2,5 mm²
5,35 x 8,70 mm
7.41 Ω/km
95.27 kg/km
A
Current Carrying Capacity in Air
23 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
2x4 mm²
6,1 x 10,2 mm
4.61 Ω/km
133.72 kg/km
A
Current Carrying Capacity in Air
30 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
2x6 mm²
6,5 x 10,80 mm
3.08 Ω/km
175.88 kg/km
A
Current Carrying Capacity in Air
39 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
3x1 mm²
4,10 x 8,70 mm
18.1 Ω/km
76.8 kg/km
A
Current Carrying Capacity in Air
11 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
3x1,5 mm²
4,55 x 10,05 mm
12.1 Ω/km
103.62 kg/km
A
Current Carrying Capacity in Air
15 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
3x10 mm²
8,2 x 19,8 mm
1.83 Ω/km
482.44 kg/km
A
Current Carrying Capacity in Air
46 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
3x16 mm²
9,35 x 22,85 mm
1.15 Ω/km
675.48 kg/km
A
Current Carrying Capacity in Air
62 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
3x2,5 mm²
5,35 x 12,05 mm
7.41 Ω/km
142.57 kg/km
A
Current Carrying Capacity in Air
20 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
3x4 mm²
6,30 x 14,5 mm
4.61 Ω/km
198.93 kg/km
A
Current Carrying Capacity in Air
27 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
3x6 mm²
6,50 x 15,10 mm
3.08 Ω/km
259.86 kg/km
A
Current Carrying Capacity in Air
34 A
Conductor Structure
Solid or Stranded Copper (Class 1;Class 2)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
BS 6004
Flame Retardant Test
IEC 60332-1
Title Type Language
YASSI NYM - FLAT NYM Ürün Ana Görseli PNG
YASSI NYM - FLAT NYM Ürün Kataloğu PDF
YASSI NYM - FLAT NYM Ürün Kesit Görseli JPG