NYY / YVV

PVC Insulated Power Cables
Used as a fixed installation cable in damp places without mechanical stress, under and over plaster, inside cable ducts, wherever transmission reliability and electromagnetic protection are needed.

Twisted
Technical Specifications
Product
10x1,5 mm²
16.8 mm
12.1 Ω/km
457.36 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
10x2,5 mm²
18.4 mm
7.41 Ω/km
595.18 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
12x1,5 mm²
17.2 mm
12.1 Ω/km
494.95 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
12x2,5 mm²
18.9 mm
7.41 Ω/km
652.33 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
14x1,5 mm²
18 mm
12.1 Ω/km
551.17 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
14x2,5 mm²
19.7 mm
7.41 Ω/km
725.81 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
15x1,5 mm²
18.8 mm
12.1 Ω/km
599.89 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
15x2,5 mm²
20.7 mm
7.41 Ω/km
795.16 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
16x1,5 mm²
18.8 mm
12.1 Ω/km
609.82 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
16x2,5 mm²
20.7 mm
7.41 Ω/km
811.71 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
19x1,5 mm²
19.7 mm
12.1 Ω/km
685.23 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
19x2,5 mm²
21.7 mm
7.41 Ω/km
917.43 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x10 mm²
8 mm
1.83 Ω/km
143.63 kg/km
A
Current Carrying Capacity in Air
64 A
Current Carrying Capacity in Ground
83 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x120 mm²
18.4 mm
0.153 Ω/km
1227.04 kg/km
A
Current Carrying Capacity in Air
307 A
Current Carrying Capacity in Ground
325 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x150 mm²
20.4 mm
0.124 Ω/km
1516.33 kg/km
A
Current Carrying Capacity in Air
352 A
Current Carrying Capacity in Ground
365 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x16 mm²
9 mm
1.15 Ω/km
204.63 kg/km
A
Current Carrying Capacity in Air
84 A
Current Carrying Capacity in Ground
107 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x185 mm²
22.6 mm
0.0991 Ω/km
1892.96 kg/km
A
Current Carrying Capacity in Air
406 A
Current Carrying Capacity in Ground
413 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x240 mm²
25.5 mm
0.0754 Ω/km
2473.53 kg/km
A
Current Carrying Capacity in Air
483 A
Current Carrying Capacity in Ground
479 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x25 mm²
10.7 mm
0.727 Ω/km
305.62 kg/km
A
Current Carrying Capacity in Air
114 A
Current Carrying Capacity in Ground
138 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x300 mm²
28.2 mm
0.0601 Ω/km
3061.68 kg/km
A
Current Carrying Capacity in Air
557 A
Current Carrying Capacity in Ground
541 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x35 mm²
11.6 mm
0.524 Ω/km
398.92 kg/km
A
Current Carrying Capacity in Air
139 A
Current Carrying Capacity in Ground
164 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x4 mm²
7.2 mm
4.61 Ω/km
89.27 kg/km
A
Current Carrying Capacity in Air
37 A
Current Carrying Capacity in Ground
50 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x50 mm²
13.2 mm
0.387 Ω/km
526.1 kg/km
A
Current Carrying Capacity in Air
169 A
Current Carrying Capacity in Ground
195 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x6 mm²
7.3 mm
3.08 Ω/km
102.5 kg/km
A
Current Carrying Capacity in Air
47 A
Current Carrying Capacity in Ground
62 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x70 mm²
14.8 mm
0.268 Ω/km
733.35 kg/km
A
Current Carrying Capacity in Air
213 A
Current Carrying Capacity in Ground
238 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x95 mm²
17.1 mm
0.193 Ω/km
1000.58 kg/km
A
Current Carrying Capacity in Air
264 A
Current Carrying Capacity in Ground
286 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
21x1,5 mm²
20.7 mm
12.1 Ω/km
758.33 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
24x2,5 mm²
25.9 mm
7.41 Ω/km
1252.31 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x1,5 mm²
9.9 mm
12.1 Ω/km
141.6 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
30 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x10 mm²
15.8 mm
1.83 Ω/km
446.28 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x16 mm²
17.7 mm
1.15 Ω/km
607.99 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x2,5 mm²
10.7 mm
7.41 Ω/km
175.52 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x25 mm²
21.1 mm
0.727 Ω/km
896.37 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x35 mm²
22.9 mm
0.524 Ω/km
1136.5 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x4 mm²
12.4 mm
4.61 Ω/km
245.98 kg/km
A
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
49 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x6 mm²
13.4 mm
3.08 Ω/km
306.16 kg/km
A
Current Carrying Capacity in Air
45 A
Current Carrying Capacity in Ground
65 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x1,5 mm²
10.3 mm
12.1 Ω/km
160.98 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x10 mm²
16.5 mm
1.83 Ω/km
537.21 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x120 mm²
39.3 mm
0.153 Ω/km
4378.89 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
318 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x120+70 mm²
41.5 mm
0,153 / 0,268 Ω/km
5019.7 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
318 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x150 mm²
43.6 mm
0.124 Ω/km
5409.53 kg/km
A
Current Carrying Capacity in Air
326 A
Current Carrying Capacity in Ground
359 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x150+70 mm²
45.2 mm
0,124 / 0,268 Ω/km
6000.8 kg/km
A
Current Carrying Capacity in Air
326 A
Current Carrying Capacity in Ground
359 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x16 mm²
18.6 mm
1.15 Ω/km
750.57 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x16+10 mm²
19.9 mm
1,15 / 1,83 Ω/km
856.63 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x185 mm²
48.5 mm
0.0991 Ω/km
6757.89 kg/km
A
Current Carrying Capacity in Air
374 A
Current Carrying Capacity in Ground
406 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x185+95 mm²
50.6 mm
0,0991 / 0,193 Ω/km
7605.4 kg/km
A
Current Carrying Capacity in Air
374 A
Current Carrying Capacity in Ground
406 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x2,5 mm²
11.2 mm
7.41 Ω/km
204.76 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x240 mm²
54.7 mm
0.0754 Ω/km
8791.17 kg/km
A
Current Carrying Capacity in Air
445 A
Current Carrying Capacity in Ground
473 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x240+120 mm²
56.6 mm
0,0754 / 0,153 Ω/km
9807.4 kg/km
A
Current Carrying Capacity in Air
445 A
Current Carrying Capacity in Ground
473 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x25 mm²
22.2 mm
0.727 Ω/km
1115.4 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x25+16 mm²
23.6 mm
0,727 / 1,15 Ω/km
1274.3 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x300 mm²
60.5 mm
0.0601 Ω/km
10861.92 kg/km
A
Current Carrying Capacity in Air
485 A
Current Carrying Capacity in Ground
525 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x35 mm²
24.4 mm
0.524 Ω/km
1451.24 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x35+16 mm²
25.2 mm
0,524 / 1,15 Ω/km
1577 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x4 mm²
13 mm
4.61 Ω/km
290.42 kg/km
A
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
47 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x50 mm²
28.2 mm
0.387 Ω/km
1936.97 kg/km
A
Current Carrying Capacity in Air
157 A
Current Carrying Capacity in Ground
188 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x50+25 mm²
29.4 mm
0,387 / 0,727 Ω/km
2155.3 kg/km
A
Current Carrying Capacity in Air
157 A
Current Carrying Capacity in Ground
188 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x6 mm²
14.1 mm
3.08 Ω/km
368.92 kg/km
A
Current Carrying Capacity in Air
43 A
Current Carrying Capacity in Ground
59 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x70 mm²
31.7 mm
0.268 Ω/km
2658.3 kg/km
A
Current Carrying Capacity in Air
199 A
Current Carrying Capacity in Ground
232 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x70+35 mm²
33.1 mm
0,268 / 0,524 Ω/km
2967.4 kg/km
A
Current Carrying Capacity in Air
199 A
Current Carrying Capacity in Ground
232 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x95 mm²
36.5 mm
0.193 Ω/km
3601.97 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x95+50 mm²
38.2 mm
0,193 / 0,387 Ω/km
4029.4 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x1,5 mm²
11.1 mm
12.1 Ω/km
189.86 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x10 mm²
18 mm
1.83 Ω/km
658.71 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x120 mm²
43.7 mm
0.153 Ω/km
5580.52 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
318 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x150 mm²
48.6 mm
0.124 Ω/km
6907.15 kg/km
A
Current Carrying Capacity in Air
326 A
Current Carrying Capacity in Ground
359 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x16 mm²
20.3 mm
1.15 Ω/km
927.3 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x185 mm²
54 mm
0.0991 Ω/km
8623.65 kg/km
A
Current Carrying Capacity in Air
374 A
Current Carrying Capacity in Ground
406 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x2,5 mm²
12.1 mm
7.41 Ω/km
244.32 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x240 mm²
61 mm
0.0754 Ω/km
11241.74 kg/km
A
Current Carrying Capacity in Air
445 A
Current Carrying Capacity in Ground
473 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x25 mm²
24.4 mm
0.727 Ω/km
1390.49 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x35 mm²
26.9 mm
0.524 Ω/km
1882.94 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x4 mm²
14.1 mm
4.61 Ω/km
349.66 kg/km
A
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
47 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x50 mm²
31 mm
0.387 Ω/km
2425.69 kg/km
A
Current Carrying Capacity in Air
157 A
Current Carrying Capacity in Ground
188 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x6 mm²
15.4 mm
3.08 Ω/km
451.21 kg/km
A
Current Carrying Capacity in Air
43 A
Current Carrying Capacity in Ground
59 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x70 mm²
35.1 mm
0.268 Ω/km
3365.45 kg/km
A
Current Carrying Capacity in Air
199 A
Current Carrying Capacity in Ground
232 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x95 mm²
40.6 mm
0.198 Ω/km
4581.63 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x1,5 mm²
11.9 mm
12.1 Ω/km
218.41 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x10 mm²
19.6 mm
1.83 Ω/km
783.02 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x120 mm²
48.4 mm
0.153 Ω/km
6809.41 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
318 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x150 mm²
53.9 mm
0.124 Ω/km
8435.84 kg/km
A
Current Carrying Capacity in Air
326 A
Current Carrying Capacity in Ground
359 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x16 mm²
22.2 mm
1.15 Ω/km
1111.69 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x185 mm²
59.9 mm
0.0991 Ω/km
10534.63 kg/km
A
Current Carrying Capacity in Air
374 A
Current Carrying Capacity in Ground
406 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x2,5 mm²
13 mm
7.41 Ω/km
283.42 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x240 mm²
67.7 mm
0.0754 Ω/km
13743.25 kg/km
A
Current Carrying Capacity in Air
445 A
Current Carrying Capacity in Ground
473 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x25 mm²
26.9 mm
0.727 Ω/km
1680.06 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x35 mm²
29.7 mm
0.524 Ω/km
2211.93 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x4 mm²
15.3 mm
4.61 Ω/km
411.62 kg/km
A
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
47 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x50 mm²
34.3 mm
0.387 Ω/km
2947.84 kg/km
A
Current Carrying Capacity in Air
157 A
Current Carrying Capacity in Ground
188 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x6 mm²
16.7 mm
3.08 Ω/km
532.82 kg/km
A
Current Carrying Capacity in Air
43 A
Current Carrying Capacity in Ground
59 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x70 mm²
38.9 mm
0.268 Ω/km
4103.36 kg/km
A
Current Carrying Capacity in Air
199 A
Current Carrying Capacity in Ground
232 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x95 mm²
44.9 mm
0.193 Ω/km
5577.11 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
7x1,5 mm²
13.8 mm
12.1 Ω/km
308.86 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
7x2,5 mm²
15 mm
7.41 Ω/km
398.59 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Title Type Language
NYY / YVV CE Kalite Sertifikası PDF
NYY / YVV CE Kalite Sertifikası PDF
NYY / YVV DOP Kalite Sertifikası PDF
NYY / YVV DOP Kalite Sertifikası PDF
NYY / YVV TSE Kalite Sertifikası PDF
NYY / YVV VDE Kalite Sertifikası PDF
NYY / YVV Ürün Ana Görseli PNG
NYY / YVV Ürün Kataloğu PDF
NYY / YVV Ürün Kataloğu PDF
NYY / YVV Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1