NYY / YVV

PVC Insulated Power Cables
Used as a fixed installation cable in damp places without mechanical stress, under and over plaster, inside cable ducts, wherever transmission reliability and electromagnetic protection are needed.

Solid
Technical Specifications
Product
1x4 mm²
7,2 mm
4,61 Ω/km
89,27 kg/km
A
Current Carrying Capacity in Air
37 A
Current Carrying Capacity in Ground
50 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x6 mm²
7,3 mm
3,08 Ω/km
102,5 kg/km
A
Current Carrying Capacity in Air
47 A
Current Carrying Capacity in Ground
62 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x10 mm²
8 mm
1,83 Ω/km
143,63 kg/km
A
Current Carrying Capacity in Air
64 A
Current Carrying Capacity in Ground
83 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x16 mm²
9 mm
1,15 Ω/km
204,63 kg/km
A
Current Carrying Capacity in Air
84 A
Current Carrying Capacity in Ground
107 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x25 mm²
10,7 mm
0,727 Ω/km
305,62 kg/km
A
Current Carrying Capacity in Air
114 A
Current Carrying Capacity in Ground
138 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x35 mm²
11,6 mm
0,524 Ω/km
398,92 kg/km
A
Current Carrying Capacity in Air
139 A
Current Carrying Capacity in Ground
164 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x50 mm²
13,2 mm
0,387 Ω/km
526,1 kg/km
A
Current Carrying Capacity in Air
169 A
Current Carrying Capacity in Ground
195 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x70 mm²
14,8 mm
0,268 Ω/km
733,35 kg/km
A
Current Carrying Capacity in Air
213 A
Current Carrying Capacity in Ground
238 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x95 mm²
17,1 mm
0,193 Ω/km
1000,58 kg/km
A
Current Carrying Capacity in Air
264 A
Current Carrying Capacity in Ground
286 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x120 mm²
18,4 mm
0,153 Ω/km
1227,04 kg/km
A
Current Carrying Capacity in Air
307 A
Current Carrying Capacity in Ground
325 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x150 mm²
20,4 mm
0,124 Ω/km
1516,33 kg/km
A
Current Carrying Capacity in Air
352 A
Current Carrying Capacity in Ground
365 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x185 mm²
22,6 mm
0,0991 Ω/km
1892,96 kg/km
A
Current Carrying Capacity in Air
406 A
Current Carrying Capacity in Ground
413 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x240 mm²
25,5 mm
0,0754 Ω/km
2473,53 kg/km
A
Current Carrying Capacity in Air
483 A
Current Carrying Capacity in Ground
479 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x300 mm²
28,2 mm
0,0601 Ω/km
3061,68 kg/km
A
Current Carrying Capacity in Air
557 A
Current Carrying Capacity in Ground
541 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x1,5 mm²
9,9 mm
12,1 Ω/km
141,6 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
30 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x2,5 mm²
10,7 mm
7,41 Ω/km
175,52 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x4 mm²
12,4 mm
4,61 Ω/km
245,98 kg/km
A
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
49 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x6 mm²
13,4 mm
3,08 Ω/km
306,16 kg/km
A
Current Carrying Capacity in Air
45 A
Current Carrying Capacity in Ground
65 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x10 mm²
15,8 mm
1,83 Ω/km
446,28 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x16 mm²
17,7 mm
1,15 Ω/km
607,99 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x25 mm²
21,1 mm
0,727 Ω/km
896,37 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x35 mm²
22,9 mm
0,524 Ω/km
1136,5 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x1,5 mm²
10,3 mm
12,1 Ω/km
160,98 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x2,5 mm²
11,2 mm
7,41 Ω/km
204,76 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x4 mm²
13 mm
4,61 Ω/km
290,42 kg/km
A
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
47 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x6 mm²
14,1 mm
3,08 Ω/km
368,92 kg/km
A
Current Carrying Capacity in Air
43 A
Current Carrying Capacity in Ground
59 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x10 mm²
16,5 mm
1,83 Ω/km
537,21 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x16 mm²
18,6 mm
1,15 Ω/km
750,57 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x16+10 mm²
19,9 mm
1,15 / 1,83 Ω/km
856,63 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x25 mm²
22,2 mm
0,727 Ω/km
1115,4 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x25+16 mm²
23,6 mm
0,727 / 1,15 Ω/km
1274,3 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x35 mm²
24,4 mm
0,524 Ω/km
1451,24 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x35+16 mm²
25,2 mm
0,524 / 1,15 Ω/km
1577 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x50 mm²
28,2 mm
0,387 Ω/km
1936,97 kg/km
A
Current Carrying Capacity in Air
157 A
Current Carrying Capacity in Ground
188 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x50+25 mm²
29,4 mm
0,387 / 0,727 Ω/km
2155,3 kg/km
A
Current Carrying Capacity in Air
157 A
Current Carrying Capacity in Ground
188 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x70 mm²
31,7 mm
0,268 Ω/km
2658,3 kg/km
A
Current Carrying Capacity in Air
199 A
Current Carrying Capacity in Ground
232 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x70+35 mm²
33,1 mm
0,268 / 0,524 Ω/km
2967,4 kg/km
A
Current Carrying Capacity in Air
199 A
Current Carrying Capacity in Ground
232 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x95 mm²
36,5 mm
0,193 Ω/km
3601,97 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x95+50 mm²
38,2 mm
0,193 / 0,387 Ω/km
4029,4 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x120 mm²
39,3 mm
0,153 Ω/km
4378,89 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
318 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x120+70 mm²
41,5 mm
0,153 / 0,268 Ω/km
5019,7 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
318 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x150 mm²
43,6 mm
0,124 Ω/km
5409,53 kg/km
A
Current Carrying Capacity in Air
326 A
Current Carrying Capacity in Ground
359 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x150+70 mm²
45,2 mm
0,124 / 0,268 Ω/km
6000,8 kg/km
A
Current Carrying Capacity in Air
326 A
Current Carrying Capacity in Ground
359 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x185 mm²
48,5 mm
0,0991 Ω/km
6757,89 kg/km
A
Current Carrying Capacity in Air
374 A
Current Carrying Capacity in Ground
406 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x185+95 mm²
50,6 mm
0,0991 / 0,193 Ω/km
7605,4 kg/km
A
Current Carrying Capacity in Air
374 A
Current Carrying Capacity in Ground
406 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x240 mm²
54,7 mm
0,0754 Ω/km
8791,17 kg/km
A
Current Carrying Capacity in Air
445 A
Current Carrying Capacity in Ground
473 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x240+120 mm²
56,6 mm
0,0754 / 0,153 Ω/km
9807,4 kg/km
A
Current Carrying Capacity in Air
445 A
Current Carrying Capacity in Ground
473 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x300 mm²
60,5 mm
0,0601 Ω/km
10861,92 kg/km
A
Current Carrying Capacity in Air
485 A
Current Carrying Capacity in Ground
525 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x1,5 mm²
11,1 mm
12,1 Ω/km
189,86 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x2,5 mm²
12,1 mm
7,41 Ω/km
244,32 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x4 mm²
14,1 mm
4,61 Ω/km
349,66 kg/km
A
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
47 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x6 mm²
15,4 mm
3,08 Ω/km
451,21 kg/km
A
Current Carrying Capacity in Air
43 A
Current Carrying Capacity in Ground
59 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x10 mm²
18 mm
1,83 Ω/km
658,71 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x16 mm²
20,3 mm
1,15 Ω/km
927,3 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x25 mm²
24,4 mm
0,727 Ω/km
1390,49 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x35 mm²
26,9 mm
0,524 Ω/km
1882,94 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x50 mm²
31 mm
0,387 Ω/km
2425,69 kg/km
A
Current Carrying Capacity in Air
157 A
Current Carrying Capacity in Ground
188 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x70 mm²
35,1 mm
0,268 Ω/km
3365,45 kg/km
A
Current Carrying Capacity in Air
199 A
Current Carrying Capacity in Ground
232 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x95 mm²
40,6 mm
0,198 Ω/km
4581,63 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x120 mm²
43,7 mm
0,153 Ω/km
5580,52 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
318 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x150 mm²
48,6 mm
0,124 Ω/km
6907,15 kg/km
A
Current Carrying Capacity in Air
326 A
Current Carrying Capacity in Ground
359 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x185 mm²
54 mm
0,0991 Ω/km
8623,65 kg/km
A
Current Carrying Capacity in Air
374 A
Current Carrying Capacity in Ground
406 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x240 mm²
61 mm
0,0754 Ω/km
11241,74 kg/km
A
Current Carrying Capacity in Air
445 A
Current Carrying Capacity in Ground
473 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x1,5 mm²
11,9 mm
12,1 Ω/km
218,41 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x2,5 mm²
13 mm
7,41 Ω/km
283,42 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x4 mm²
15,3 mm
4,61 Ω/km
411,62 kg/km
A
Current Carrying Capacity in Air
34 A
Current Carrying Capacity in Ground
47 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x6 mm²
16,7 mm
3,08 Ω/km
532,82 kg/km
A
Current Carrying Capacity in Air
43 A
Current Carrying Capacity in Ground
59 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x10 mm²
19,6 mm
1,83 Ω/km
783,02 kg/km
A
Current Carrying Capacity in Air
59 A
Current Carrying Capacity in Ground
79 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x16 mm²
22,2 mm
1,15 Ω/km
1111,69 kg/km
A
Current Carrying Capacity in Air
79 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x25 mm²
26,9 mm
0,727 Ω/km
1680,06 kg/km
A
Current Carrying Capacity in Air
106 A
Current Carrying Capacity in Ground
133 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x35 mm²
29,7 mm
0,524 Ω/km
2211,93 kg/km
A
Current Carrying Capacity in Air
129 A
Current Carrying Capacity in Ground
159 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x50 mm²
34,3 mm
0,387 Ω/km
2947,84 kg/km
A
Current Carrying Capacity in Air
157 A
Current Carrying Capacity in Ground
188 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x70 mm²
38,9 mm
0,268 Ω/km
4103,36 kg/km
A
Current Carrying Capacity in Air
199 A
Current Carrying Capacity in Ground
232 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x95 mm²
44,9 mm
0,193 Ω/km
5577,11 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x120 mm²
48,4 mm
0,153 Ω/km
6809,41 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
318 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x150 mm²
53,9 mm
0,124 Ω/km
8435,84 kg/km
A
Current Carrying Capacity in Air
326 A
Current Carrying Capacity in Ground
359 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x185 mm²
59,9 mm
0,0991 Ω/km
10534,63 kg/km
A
Current Carrying Capacity in Air
374 A
Current Carrying Capacity in Ground
406 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x240 mm²
67,7 mm
0,0754 Ω/km
13743,25 kg/km
A
Current Carrying Capacity in Air
445 A
Current Carrying Capacity in Ground
473 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
7x1,5 mm²
13,8 mm
12,1 Ω/km
308,86 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
7x2,5 mm²
15 mm
7,41 Ω/km
398,59 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
10x1,5 mm²
16,8 mm
12,1 Ω/km
457,36 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
10x2,5 mm²
18,4 mm
7,41 Ω/km
595,18 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
12x1,5 mm²
17,2 mm
12,1 Ω/km
494,95 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
12x2,5 mm²
18,9 mm
7,41 Ω/km
652,33 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
14x1,5 mm²
18 mm
12,1 Ω/km
551,17 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
14x2,5 mm²
19,7 mm
7,41 Ω/km
725,81 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
15x1,5 mm²
18,8 mm
12,1 Ω/km
599,89 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
15x2,5 mm²
20,7 mm
7,41 Ω/km
795,16 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
16x1,5 mm²
18,8 mm
12,1 Ω/km
609,82 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
16x2,5 mm²
20,7 mm
7,41 Ω/km
811,71 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
19x1,5 mm²
19,7 mm
12,1 Ω/km
685,23 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
19x2,5 mm²
21,7 mm
7,41 Ω/km
917,43 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
21x1,5 mm²
20,7 mm
12,1 Ω/km
758,33 kg/km
A
Current Carrying Capacity in Air
20 A
Current Carrying Capacity in Ground
27 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
24x2,5 mm²
25,9 mm
7,41 Ω/km
1252,31 kg/km
A
Current Carrying Capacity in Air
25 A
Current Carrying Capacity in Ground
36 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Title Type Language
NYY / YVV CE Kalite Sertifikası PDF
NYY / YVV CE Kalite Sertifikası PDF
NYY / YVV DOP Kalite Sertifikası PDF
NYY / YVV DOP Kalite Sertifikası PDF
NYY / YVV TSE Kalite Sertifikası PDF
NYY / YVV VDE Kalite Sertifikası PDF
NYY / YVV Ürün Ana Görseli PNG
NYY / YVV Ürün Kataloğu PDF
NYY / YVV Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1