NYCY (SM)

PVC Insulated Power Cables with Stranded Sectoral Conductor and Concentric Copper Wire Screen
Suitable for heavy-duty conditions where protection against external effects and mechanical strength are important. Thanks to its armored structure, it is resistant to impacts from outside. Resistant to sudden and short-term increases in working temperature. Used as a network and lighting cable, in cable ducts, under plaster, and underground.

Twisted
Technical Specifications
Product
3x50 SM/25 mm²
29,7 mm
0,387 Ω/km
2139,53 kg/km
A
Current Carrying Capacity in Air
160 A
Current Carrying Capacity in Ground
190 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x70 SM/35 mm²
33,1 mm
0,268 Ω/km
2952,22 kg/km
A
Current Carrying Capacity in Air
202 A
Current Carrying Capacity in Ground
234 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x95 SM/50 mm²
37,5 mm
0,193 Ω/km
3958,9 kg/km
A
Current Carrying Capacity in Air
249 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x120 SM/70 mm²
40,6 mm
0,153 Ω/km
4929,99 kg/km
A
Current Carrying Capacity in Air
289 A
Current Carrying Capacity in Ground
319 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x150 SM/70 mm²
44,8 mm
0,124 Ω/km
5852,32 kg/km
A
Current Carrying Capacity in Air
329 A
Current Carrying Capacity in Ground
357 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x185 SM/95 mm²
49,5 mm
0,0991 Ω/km
7333,18 kg/km
A
Current Carrying Capacity in Air
377 A
Current Carrying Capacity in Ground
402 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x240 SM/120 mm²
55,5 mm
0,0754 Ω/km
9532,1 kg/km
A
Current Carrying Capacity in Air
443 A
Current Carrying Capacity in Ground
463 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x50 SM/25 mm²
34,5 mm
0,387 Ω/km
2730,94 kg/km
A
Current Carrying Capacity in Air
160 A
Current Carrying Capacity in Ground
190 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x70 SM/35 mm²
38,2 mm
0,268 Ω/km
3760,47 kg/km
A
Current Carrying Capacity in Air
202 A
Current Carrying Capacity in Ground
234 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x95 SM/50 mm²
43,9 mm
0,193 Ω/km
5076,56 kg/km
A
Current Carrying Capacity in Air
249 A
Current Carrying Capacity in Ground
280 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x120 SM/70 mm²
47,9 mm
0,153 Ω/km
6318,12 kg/km
A
Current Carrying Capacity in Air
289 A
Current Carrying Capacity in Ground
319 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x150 SM/70 mm²
52,6 mm
0,124 Ω/km
7535,39 kg/km
A
Current Carrying Capacity in Air
329 A
Current Carrying Capacity in Ground
357 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x185 SM/95 mm²
58,3 mm
0,0991 Ω/km
9422,27 kg/km
A
Current Carrying Capacity in Air
377 A
Current Carrying Capacity in Ground
402 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x240 SM/120 mm²
65,8 mm
0,0754 Ω/km
12282,11 kg/km
A
Current Carrying Capacity in Air
443 A
Current Carrying Capacity in Ground
463 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PP Tape / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor and Copper Tape
Tape
Concentric Copper Wire & Copper Tape
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
Title Type Language