N2XY (SM)

XLPE Insulated Power Cables with Stranded Sectoral Conductor
Resistant to short-term sudden temperature increases. It has higher electrical insulation compared to PVC. Used in facilities with sudden load changes, in high working temperatures within buildings, and industrial factories or distribution centers where mechanical damage is not expected.

Twisted
Technical Specifications
Product
3x120 SM mm²
32.5 mm
0.153 Ω/km
3660.3 kg/km
A
Current Carrying Capacity in Air
359 A
Current Carrying Capacity in Ground
348 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x120 SM/70 SM mm²
37.4 mm
0,153 / 0,268 Ω/km
4377.5 kg/km
A
Current Carrying Capacity in Air
359 A
Current Carrying Capacity in Ground
348 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x150 SM mm²
36.7 mm
0.124 Ω/km
4535.7 kg/km
A
Current Carrying Capacity in Air
412 A
Current Carrying Capacity in Ground
392 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x150 SM/70 SM mm²
41.3 mm
0,124 / 0,268 Ω/km
5255.9 kg/km
A
Current Carrying Capacity in Air
412 A
Current Carrying Capacity in Ground
392 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x185 SM mm²
40.8 mm
0.0991 Ω/km
5627 kg/km
A
Current Carrying Capacity in Air
475 A
Current Carrying Capacity in Ground
444 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x185 SM/95 SM mm²
46.1 mm
0,0991 / 0,193 Ω/km
6615.8 kg/km
A
Current Carrying Capacity in Air
475 A
Current Carrying Capacity in Ground
444 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x240 SM mm²
45.9 mm
0.0754 Ω/km
7333.6 kg/km
A
Current Carrying Capacity in Air
564 A
Current Carrying Capacity in Ground
517 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x240 SM/120 SM mm²
52 mm
0,754 / 0,153 Ω/km
8572.4 kg/km
A
Current Carrying Capacity in Air
564 A
Current Carrying Capacity in Ground
517 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x50 SM mm²
22.6 mm
0.387 Ω/km
1528.5 kg/km
A
Current Carrying Capacity in Air
197 A
Current Carrying Capacity in Ground
206 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x50 SM/25 SM mm²
26 mm
0,387 / 0,727 Ω/km
1799.6 kg/km
A
Current Carrying Capacity in Air
197 A
Current Carrying Capacity in Ground
206 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x70 SM mm²
26.1 mm
0.268 Ω/km
2152.8 kg/km
A
Current Carrying Capacity in Air
250 A
Current Carrying Capacity in Ground
254 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x70 SM/35 SM mm²
29.4 mm
0,268 / 0,524 Ω/km
2521.5 kg/km
A
Current Carrying Capacity in Air
250 A
Current Carrying Capacity in Ground
254 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x95 SM mm²
29.3 mm
0.193 Ω/km
2927.8 kg/km
A
Current Carrying Capacity in Air
308 A
Current Carrying Capacity in Ground
305 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x95 SM/50 SM mm²
33.9 mm
0,193 / 0,387 Ω/km
3440.1 kg/km
A
Current Carrying Capacity in Air
308 A
Current Carrying Capacity in Ground
305 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x120 SM mm²
39.6 mm
0.153 Ω/km
4892.9 kg/km
A
Current Carrying Capacity in Air
359 A
Current Carrying Capacity in Ground
348 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x150 SM mm²
44.2 mm
0.124 Ω/km
6052.2 kg/km
A
Current Carrying Capacity in Air
412 A
Current Carrying Capacity in Ground
392 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x185 SM mm²
49.4 mm
0.0991 Ω/km
7520.3 kg/km
A
Current Carrying Capacity in Air
475 A
Current Carrying Capacity in Ground
444 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x240 SM mm²
55.8 mm
0.0754 Ω/km
9796.4 kg/km
A
Current Carrying Capacity in Air
564 A
Current Carrying Capacity in Ground
517 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x50 SM mm²
26.8 mm
0.387 Ω/km
2011.3 kg/km
A
Current Carrying Capacity in Air
197 A
Current Carrying Capacity in Ground
206 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x70 SM mm²
31 mm
0.268 Ω/km
2860.3 kg/km
A
Current Carrying Capacity in Air
250 A
Current Carrying Capacity in Ground
254 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x95 SM mm²
35.4 mm
0.193 Ω/km
3904.9 kg/km
A
Current Carrying Capacity in Air
308 A
Current Carrying Capacity in Ground
305 A
Conductor Structure
Sector Conducted Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
PP Tape
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1