N2XRH

XLPE Insulated Halogen Free Flame Retardant Power Cables with Round Steel Wire Armour
Used in hospitals, schools, hotels, shopping centers, data centers, public transport facilities, tunnels, and power plants.

Halogen Free
Twisted
Technical Specifications
Product
1x10 mm²
12.97 mm
1.83 Ω/km
265.9 kg/km
A
Current Carrying Capacity in Air
77 A
Current Carrying Capacity in Ground
89 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
1x120 mm²
24.54 mm
0.153 Ω/km
1559.5 kg/km
A
Current Carrying Capacity in Air
380 A
Current Carrying Capacity in Ground
349 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
1x150 mm²
26.46 mm
0.124 Ω/km
1857.8 kg/km
A
Current Carrying Capacity in Air
437 A
Current Carrying Capacity in Ground
393 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
1x16 mm²
13.98 mm
1.15 Ω/km
338.53 kg/km
A
Current Carrying Capacity in Air
102 A
Current Carrying Capacity in Ground
115 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
1x185 mm²
28.73 mm
0.0991 Ω/km
2268.7 kg/km
A
Current Carrying Capacity in Air
507 A
Current Carrying Capacity in Ground
445 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
1x240 mm²
32.29 mm
0.0754 Ω/km
2942.8 kg/km
A
Current Carrying Capacity in Air
604 A
Current Carrying Capacity in Ground
517 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
1x25 mm²
16.61 mm
0.727 Ω/km
495.68 kg/km
A
Current Carrying Capacity in Air
138 A
Current Carrying Capacity in Ground
148 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
1x35 mm²
17.47 mm
0.524 Ω/km
602.78 kg/km
A
Current Carrying Capacity in Air
170 A
Current Carrying Capacity in Ground
177 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
1x50 mm²
18.88 mm
0.387 Ω/km
742.41 kg/km
A
Current Carrying Capacity in Air
207 A
Current Carrying Capacity in Ground
209 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
1x70 mm²
20.7 mm
0.268 Ω/km
980.31 kg/km
A
Current Carrying Capacity in Air
263 A
Current Carrying Capacity in Ground
256 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
1x95 mm²
23.12 mm
0.193 Ω/km
1299.2 kg/km
A
Current Carrying Capacity in Air
325 A
Current Carrying Capacity in Ground
307 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
2x1,5 mm²
13.88 mm
12.1 Ω/km
346.51 kg/km
A
Current Carrying Capacity in Air
24 A
Current Carrying Capacity in Ground
31 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
2x10 mm²
19.74 mm
1.83 Ω/km
840.44 kg/km
A
Current Carrying Capacity in Air
74 A
Current Carrying Capacity in Ground
86 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
2x16 mm²
22.47 mm
1.15 Ω/km
1179.6 kg/km
A
Current Carrying Capacity in Air
98 A
Current Carrying Capacity in Ground
112 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
2x2,5 mm²
14.69 mm
7.41 Ω/km
396.69 kg/km
A
Current Carrying Capacity in Air
32 A
Current Carrying Capacity in Ground
40 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
2x25 mm²
25.9 mm
0.727 Ω/km
1575 kg/km
A
Current Carrying Capacity in Air
133 A
Current Carrying Capacity in Ground
145 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
2x35 mm²
28 mm
0.524 Ω/km
1853 kg/km
A
Current Carrying Capacity in Air
162 A
Current Carrying Capacity in Ground
174 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
2x4 mm²
16.51 mm
4.61 Ω/km
557.61 kg/km
A
Current Carrying Capacity in Air
42 A
Current Carrying Capacity in Ground
52 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
2x6 mm²
17.52 mm
3.08 Ω/km
650.97 kg/km
A
Current Carrying Capacity in Air
53 A
Current Carrying Capacity in Ground
64 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x1,5 mm²
14.33 mm
12.1 Ω/km
374.52 kg/km
A
Current Carrying Capacity in Air
24 A
Current Carrying Capacity in Ground
31 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x10 mm²
20.58 mm
1.83 Ω/km
953.07 kg/km
A
Current Carrying Capacity in Air
74 A
Current Carrying Capacity in Ground
86 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x120 mm²
45.86 mm
0.153 Ω/km
6244.5 kg/km
A
Current Carrying Capacity in Air
359 A
Current Carrying Capacity in Ground
348 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x16 mm²
23.47 mm
1.15 Ω/km
1354.2 kg/km
A
Current Carrying Capacity in Air
98 A
Current Carrying Capacity in Ground
112 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x16+10 mm²
24.61 mm
1,15 / 1,83 Ω/km
1492.9 kg/km
A
Current Carrying Capacity in Air
98 A
Current Carrying Capacity in Ground
112 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x2,5 mm²
15.2 mm
7.41 Ω/km
433.38 kg/km
A
Current Carrying Capacity in Air
32 A
Current Carrying Capacity in Ground
40 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x25 mm²
27.23 mm
0.727 Ω/km
1845.6 kg/km
A
Current Carrying Capacity in Air
133 A
Current Carrying Capacity in Ground
145 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x25+16 mm²
28.51 mm
0,727 / 1,15 Ω/km
2033.7 kg/km
A
Current Carrying Capacity in Air
133 A
Current Carrying Capacity in Ground
145 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x35 mm²
29.21 mm
0.524 Ω/km
2240 kg/km
A
Current Carrying Capacity in Air
162 A
Current Carrying Capacity in Ground
174 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x35+16 mm²
30.19 mm
0,524 / 1,15 Ω/km
2393 kg/km
A
Current Carrying Capacity in Air
162 A
Current Carrying Capacity in Ground
174 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x4 mm²
17.09 mm
4.61 Ω/km
619.33 kg/km
A
Current Carrying Capacity in Air
42 A
Current Carrying Capacity in Ground
52 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x50 mm²
32.48 mm
0.387 Ω/km
2782.5 kg/km
A
Current Carrying Capacity in Air
197 A
Current Carrying Capacity in Ground
206 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x50+25 mm²
34.96 mm
0,387 / 0,727 Ω/km
3305.2 kg/km
A
Current Carrying Capacity in Air
197 A
Current Carrying Capacity in Ground
206 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x6 mm²
18.18 mm
3.08 Ω/km
719.82 kg/km
A
Current Carrying Capacity in Air
53 A
Current Carrying Capacity in Ground
64 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x70 mm²
37.55 mm
0.268 Ω/km
3887.1 kg/km
A
Current Carrying Capacity in Air
250 A
Current Carrying Capacity in Ground
254 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
3x95 mm²
42.6 mm
0.193 Ω/km
5247.4 kg/km
A
Current Carrying Capacity in Air
308 A
Current Carrying Capacity in Ground
305 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x1,5 mm²
13.03 mm
12.1 Ω/km
393.88 kg/km
A
Current Carrying Capacity in Air
24 A
Current Carrying Capacity in Ground
31 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x10 mm²
22.65 mm
1.83 Ω/km
1215.2 kg/km
A
Current Carrying Capacity in Air
74 A
Current Carrying Capacity in Ground
86 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x16 mm²
25.1 mm
1.15 Ω/km
1575.8 kg/km
A
Current Carrying Capacity in Air
98 A
Current Carrying Capacity in Ground
112 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x2,5 mm²
16.94 mm
7.41 Ω/km
583.64 kg/km
A
Current Carrying Capacity in Air
32 A
Current Carrying Capacity in Ground
40 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x25 mm²
29.45 mm
0.727 Ω/km
2185.7 kg/km
A
Current Carrying Capacity in Air
133 A
Current Carrying Capacity in Ground
145 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x35 mm²
32.54 mm
0.524 Ω/km
2859.1 kg/km
A
Current Carrying Capacity in Air
162 A
Current Carrying Capacity in Ground
174 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x4 mm²
18.03 mm
4.61 Ω/km
693.81 kg/km
A
Current Carrying Capacity in Air
42 A
Current Carrying Capacity in Ground
52 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x50 mm²
36.2 mm
0.387 Ω/km
3594.1 kg/km
A
Current Carrying Capacity in Air
197 A
Current Carrying Capacity in Ground
206 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x6 mm²
19.26 mm
3.08 Ω/km
824.17 kg/km
A
Current Carrying Capacity in Air
53 A
Current Carrying Capacity in Ground
64 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x70 mm²
41.98 mm
0.268 Ω/km
5095.2 kg/km
A
Current Carrying Capacity in Air
250 A
Current Carrying Capacity in Ground
254 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
4x95 mm²
46.43 mm
0.193 Ω/km
6460.5 kg/km
A
Current Carrying Capacity in Air
308 A
Current Carrying Capacity in Ground
305 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x1,5 mm²
16.74 mm
12.1 Ω/km
556.26 kg/km
A
Current Carrying Capacity in Air
24 A
Current Carrying Capacity in Ground
31 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x10 mm²
24.12 mm
1.83 Ω/km
1383.6 kg/km
A
Current Carrying Capacity in Air
74 A
Current Carrying Capacity in Ground
86 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x120 mm²
56.05 mm
0.153 Ω/km
9727.2 kg/km
A
Current Carrying Capacity in Air
359 A
Current Carrying Capacity in Ground
348 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x16 mm²
26.88 mm
1.15 Ω/km
1804.3 kg/km
A
Current Carrying Capacity in Air
98 A
Current Carrying Capacity in Ground
112 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x2,5 mm²
17.83 mm
7.41 Ω/km
644.27 kg/km
A
Current Carrying Capacity in Air
32 A
Current Carrying Capacity in Ground
40 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x25 mm²
32.7 mm
0.727 Ω/km
2749.2 kg/km
A
Current Carrying Capacity in Air
133 A
Current Carrying Capacity in Ground
145 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x35 mm²
35.18 mm
0.524 Ω/km
3340.1 kg/km
A
Current Carrying Capacity in Air
162 A
Current Carrying Capacity in Ground
174 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x4 mm²
19.05 mm
4.61 Ω/km
770.53 kg/km
A
Current Carrying Capacity in Air
42 A
Current Carrying Capacity in Ground
52 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x50 mm²
39.48 mm
0.387 Ω/km
4269.1 kg/km
A
Current Carrying Capacity in Air
197 A
Current Carrying Capacity in Ground
206 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x6 mm²
20.42 mm
3.08 Ω/km
931.24 kg/km
A
Current Carrying Capacity in Air
53 A
Current Carrying Capacity in Ground
64 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x70 mm²
45.6 mm
0.268 Ω/km
5975.2 kg/km
A
Current Carrying Capacity in Air
250 A
Current Carrying Capacity in Ground
254 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
5x95 mm²
50.56 mm
0.193 Ω/km
7639.7 kg/km
A
Current Carrying Capacity in Air
308 A
Current Carrying Capacity in Ground
305 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Filler
HFFR / HFFR Inner Sheath
Sheath
HFFR
Current Type
AC
Layer Structure
Round Steel Wire / PP Tape
Armour
Yuvarlak Çelik Tel
Tape
Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS HD 604 S1
Flame Retardant Test
IEC 60332-1
Flame Propagation Test
EN 60332-3-24
Smoke Density Test
EN 61034-2
Halogen Free Test
EN 60754-2
Title Type Language