H07Z1-R

Halogen Free Stationary Installation Cables
Used in enclosed areas that require higher safety in case of fire, such as hotels, schools, high-rise buildings, hospitals, data centers, and business centers where people are densely populated.

Halogen Free
Twisted
Technical Specifications
Product
1,5 mm²
2.95 mm
12.1 Ω/km
20.37 kg/km
A
Current Carrying Capacity in Air
24 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
10 mm²
5.8 mm
1.83 Ω/km
107.81 kg/km
A
Current Carrying Capacity in Air
73 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
120 mm²
15.85 mm
0.153 Ω/km
1123.9 kg/km
A
Current Carrying Capacity in Air
344 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
150 mm²
17.75 mm
0.124 Ω/km
1397 kg/km
A
Current Carrying Capacity in Air
391 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
16 mm²
6.75 mm
1.15 Ω/km
162.83 kg/km
A
Current Carrying Capacity in Air
98 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
185 mm²
19.85 mm
0.0991 Ω/km
1755.1 kg/km
A
Current Carrying Capacity in Air
448 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
2,5 mm²
3.6 mm
7.41 Ω/km
32.21 kg/km
A
Current Carrying Capacity in Air
32 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
240 mm²
22.55 mm
0.0754 Ω/km
2306.1 kg/km
A
Current Carrying Capacity in Air
528 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
25 mm²
8.45 mm
0.727 Ω/km
254.77 kg/km
A
Current Carrying Capacity in Air
129 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
300 mm²
25.05 mm
0.0601 Ω/km
2863.5 kg/km
A
Current Carrying Capacity in Air
608 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
35 mm²
9.35 mm
0.524 Ω/km
343.29 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
4 mm²
4.1 mm
4.61 Ω/km
46.6 kg/km
A
Current Carrying Capacity in Air
42 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
50 mm²
10.95 mm
0.387 Ω/km
461.96 kg/km
A
Current Carrying Capacity in Air
198 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
6 mm²
4.65 mm
3.08 Ω/km
65.16 kg/km
A
Current Carrying Capacity in Air
54 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
70 mm²
12.55 mm
0.268 Ω/km
660.71 kg/km
A
Current Carrying Capacity in Air
245 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
95 mm²
14.65 mm
0.193 Ω/km
908.74 kg/km
A
Current Carrying Capacity in Air
292 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
HFFR
Current Type
AC
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1