H07Z-R

Halogen Free Stationary Installation Cables
Used in enclosed areas that require higher safety in case of fire, such as hotels, schools, high-rise buildings, hospitals, data centers, and business centers where people are densely populated.

Halogen Free
Twisted
Technical Specifications
Product
1,5 mm²
2,95 mm
12,1 Ω/km
20,37 kg/km
A
Current Carrying Capacity in Air
24 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
2,5 mm²
3,6 mm
7,41 Ω/km
32,21 kg/km
A
Current Carrying Capacity in Air
32 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
4 mm²
4,1 mm
4,61 Ω/km
46,6 kg/km
A
Current Carrying Capacity in Air
42 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
6 mm²
4,65 mm
3,08 Ω/km
65,16 kg/km
A
Current Carrying Capacity in Air
54 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
10 mm²
5,8 mm
1,83 Ω/km
107,81 kg/km
A
Current Carrying Capacity in Air
73 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
16 mm²
6,75 mm
1,15 Ω/km
162,83 kg/km
A
Current Carrying Capacity in Air
98 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
25 mm²
8,45 mm
0,727 Ω/km
254,77 kg/km
A
Current Carrying Capacity in Air
129 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
35 mm²
9,35 mm
0,524 Ω/km
343,29 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
50 mm²
10,95 mm
0,387 Ω/km
461,96 kg/km
A
Current Carrying Capacity in Air
198 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
70 mm²
12,55 mm
0,268 Ω/km
660,71 kg/km
A
Current Carrying Capacity in Air
245 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
95 mm²
14,65 mm
0,193 Ω/km
908,74 kg/km
A
Current Carrying Capacity in Air
292 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
120 mm²
15,85 mm
0,153 Ω/km
1123,93 kg/km
A
Current Carrying Capacity in Air
344 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
150 mm²
17,75 mm
0,124 Ω/km
1396,96 kg/km
A
Current Carrying Capacity in Air
391 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
185 mm²
19,85 mm
0,0991 Ω/km
1755,1 kg/km
A
Current Carrying Capacity in Air
448 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
240 mm²
22,55 mm
0,0754 Ω/km
2306,11 kg/km
A
Current Carrying Capacity in Air
528 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1
300 mm²
25,05 mm
0,0601 Ω/km
2863,55 kg/km
A
Current Carrying Capacity in Air
608 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
XL HFFR
Current Type
AC
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
TS EN 50525-3-31
Flame Retardant Test
IEC 60332-1