H07V3-R

PVC Insulated Cold Resistant Stationary Installation Cables
Used at low temperatures, in dry places, fixed installations, distribution panels, and enclosed areas, under or over plaster in factories, workshops, and all types of workplaces.

Twisted
Technical Specifications
Product
1,5 mm²
2.95 mm
12.1 Ω/km
20.08 kg/km
A
Current Carrying Capacity in Air
24 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
10 mm²
5.8 mm
1.83 Ω/km
106.28 kg/km
A
Current Carrying Capacity in Air
73 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
120 mm²
15.85 mm
0.153 Ω/km
1116.07 kg/km
A
Current Carrying Capacity in Air
345 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
150 mm²
17.75 mm
0.124 Ω/km
1387.8 kg/km
A
Current Carrying Capacity in Air
390 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
16 mm²
6.77 mm
1.15 Ω/km
161.29 kg/km
A
Current Carrying Capacity in Air
98 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
185 mm²
19.85 mm
0.0991 Ω/km
1743.8 kg/km
A
Current Carrying Capacity in Air
445 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
2,5 mm²
3.6 mm
7.41 Ω/km
31.8 kg/km
A
Current Carrying Capacity in Air
32 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
240 mm²
22.55 mm
0.0754 Ω/km
2291.9 kg/km
A
Current Carrying Capacity in Air
525 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
25 mm²
8.47 mm
0.727 Ω/km
252.38 kg/km
A
Current Carrying Capacity in Air
129 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
300 mm²
25.05 mm
0.0601 Ω/km
2846.3 kg/km
A
Current Carrying Capacity in Air
605 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
35 mm²
9.35 mm
0.524 Ω/km
340.17 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
4 mm²
4.1 mm
4.61 Ω/km
46.12 kg/km
A
Current Carrying Capacity in Air
42 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
50 mm²
10.95 mm
0.387 Ω/km
457.7 kg/km
A
Current Carrying Capacity in Air
197 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
6 mm²
4.65 mm
3.08 Ω/km
64.59 kg/km
A
Current Carrying Capacity in Air
54 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
70 mm²
12.55 mm
0.268 Ω/km
655.73 kg/km
A
Current Carrying Capacity in Air
245 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
95 mm²
14.65 mm
0.193 Ω/km
902.09 kg/km
A
Current Carrying Capacity in Air
290 A
Conductor Structure
Stranded Copper (Class 2)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Title Type Language
H07V3-R Ürün Ana Görseli PNG
H07V3-R Ürün Kataloğu PDF
H07V3-R Ürün Kesit Görseli JPG
How can we help you?