H07V3-K
PVC Insulated Cold Resistant Flexible Installation Cables
Used at low temperatures, under plaster and over plaster applications, inside ducts or similar enclosed systems.


Twisted
Technical Specifications
Product
Current Carrying Capacity in Air
24 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
73 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
344 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
391 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
98 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
448 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
32 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
528 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
129 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
620 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
158 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
42 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
198 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
54 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
245 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
292 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1