H07V2-U

PVC Insulated Heat Resistant Stationary Installation Cables
Used in conditions requiring high operating temperatures (+90 °C) in household appliances, fixed installations, dry locations, distribution panels, and enclosed areas, under plaster or on plaster in factories, workshops, and all kinds of workplaces.

Solid
Technical Specifications
Product
1,5 mm²
2,75 mm
12,1 Ω/km
19,09 kg/km
A
Current Carrying Capacity in Air
24 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
2,5 mm²
3,35 mm
7,41 Ω/km
29,91 kg/km
A
Current Carrying Capacity in Air
32 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
4 mm²
3,8 mm
4,61 Ω/km
44,35 kg/km
A
Current Carrying Capacity in Air
42 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
6 mm²
4,3 mm
3,08 Ω/km
62,98 kg/km
A
Current Carrying Capacity in Air
54 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
10 mm²
5,45 mm
1,83 Ω/km
103,33 kg/km
A
Current Carrying Capacity in Air
73 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1