H07V2-U
PVC Insulated Heat Resistant Stationary Installation Cables
Used in conditions requiring high operating temperatures (+90 °C) in household appliances, fixed installations, dry locations, distribution panels, and enclosed areas, under plaster or on plaster in factories, workshops, and all kinds of workplaces.


Solid
Technical Specifications
Product
Current Carrying Capacity in Air
24 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
73 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
32 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
42 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
Current Carrying Capacity in Air
54 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1