H07V2-U

PVC Insulated Heat Resistant Stationary Installation Cables
Used in conditions requiring high operating temperatures (+90 °C) in household appliances, fixed installations, dry locations, distribution panels, and enclosed areas, under plaster or on plaster in factories, workshops, and all kinds of workplaces.

Solid
Technical Specifications
Product
1,5 mm²
2.75 mm
12.1 Ω/km
19.09 kg/km
A
Current Carrying Capacity in Air
24 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
10 mm²
5.45 mm
1.83 Ω/km
103.33 kg/km
A
Current Carrying Capacity in Air
73 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
2,5 mm²
3.35 mm
7.41 Ω/km
29.91 kg/km
A
Current Carrying Capacity in Air
32 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
4 mm²
3.8 mm
4.61 Ω/km
44.35 kg/km
A
Current Carrying Capacity in Air
42 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1
6 mm²
4.3 mm
3.08 Ω/km
62.98 kg/km
A
Current Carrying Capacity in Air
54 A
Conductor Structure
Solid Copper (Class 1)
Operating Voltage (AC)
450 / 750 VAC
Operating Voltage (DC)
450 / 750 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
High Temperature Resistant PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525-2-31
Flame Retardant Test
IEC 60332-1