H05VV-F

PVC Insulated Multi Core Flexible Installation Cables
Its flexible structure provides an advantage in narrow spaces. Used in connections of mobile devices in closed, dry, humid, and damp places where mechanical stress is low.

Twisted
Technical Specifications
Product
2x0,75 mm²
6.1 mm
26 Ω/km
53.39 kg/km
A
Current Carrying Capacity in Air
12 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
2x1 mm²
6.6 mm
19.5 Ω/km
64.06 kg/km
A
Current Carrying Capacity in Air
16 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
2x1,5 mm²
7.5 mm
13.3 Ω/km
84.89 kg/km
A
Current Carrying Capacity in Air
20 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
2x2,5 mm²
9.1 mm
7.98 Ω/km
128.58 kg/km
A
Current Carrying Capacity in Air
25 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
2x4 mm²
10.3 mm
4.95 Ω/km
174.57 kg/km
A
Current Carrying Capacity in Air
34 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x0,75 mm²
6.46 mm
26 Ω/km
63.53 kg/km
A
Current Carrying Capacity in Air
12 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x1 mm²
6.9 mm
19.5 Ω/km
75.24 kg/km
A
Current Carrying Capacity in Air
16 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x1,5 mm²
8.17 mm
13.3 Ω/km
106.66 kg/km
A
Current Carrying Capacity in Air
20 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x2,5 mm²
9.87 mm
7.98 Ω/km
161.34 kg/km
A
Current Carrying Capacity in Air
25 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x4 mm²
10.95 mm
4.95 Ω/km
215.71 kg/km
A
Current Carrying Capacity in Air
34 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x0,75 mm²
7.05 mm
26 Ω/km
77.67 kg/km
A
Current Carrying Capacity in Air
12 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x1 mm²
7.85 mm
19.5 Ω/km
98.19 kg/km
A
Current Carrying Capacity in Air
16 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x1,5 mm²
9.14 mm
13.3 Ω/km
135.79 kg/km
A
Current Carrying Capacity in Air
20 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x2,5 mm²
10.79 mm
7.98 Ω/km
199.46 kg/km
A
Current Carrying Capacity in Air
25 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x4 mm²
12.2 mm
4.95 Ω/km
274.89 kg/km
A
Current Carrying Capacity in Air
34 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
5x0,75 mm²
7.88 mm
26 Ω/km
94.19 kg/km
A
Current Carrying Capacity in Air
12 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
5x1 mm²
8.55 mm
19.5 Ω/km
114.57 kg/km
A
Current Carrying Capacity in Air
16 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
5x1,5 mm²
10.03 mm
13.3 Ω/km
160.49 kg/km
A
Current Carrying Capacity in Air
20 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
5x2,5 mm²
11.99 mm
7.98 Ω/km
239.95 kg/km
A
Current Carrying Capacity in Air
25 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
5x4 mm²
13.74 mm
4.95 Ω/km
337.39 kg/km
A
Current Carrying Capacity in Air
34 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
Title Type Language
H05VV-F HAR Kalite Sertifikası PDF
H05VV-F CE Kalite Sertifikası PDF
H05VV-F DOP Kalite Sertifikası PDF
H05VV-F Ürün Ana Görseli PNG
H05VV-F Ürün Kataloğu PDF
How can we help you?
Or
Adobestock 558884015 1