ARCTIC FLEXIBLE CABLE

PVC Insulated Cold Resistant Multi Core Flexible Installation Cables
Used at low temperatures in dry and enclosed areas where mechanical load is low, for connections of mobile devices.

Twisted
Technical Specifications
Product
2x0,50 mm²
5 mm
39 Ω/km
34.83 kg/km
A
Current Carrying Capacity in Air
8 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 300 VAC
Operating Voltage (DC)
300 / 300 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
2x0,75 mm²
6.2 mm
26 Ω/km
53.31 kg/km
A
Current Carrying Capacity in Air
12 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
2x1 mm²
6.5 mm
19.5 Ω/km
60.85 kg/km
A
Current Carrying Capacity in Air
16 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
2x1,5 mm²
7.4 mm
13.3 Ω/km
81.04 kg/km
A
Current Carrying Capacity in Air
20 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
2x2,5 mm²
9.1 mm
7.98 Ω/km
125.41 kg/km
A
Current Carrying Capacity in Air
25 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
2x4 mm²
10.3 mm
4.95 Ω/km
170.54 kg/km
A
Current Carrying Capacity in Air
34 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x0,50 mm²
5.2 mm
39 Ω/km
40.47 kg/km
A
Current Carrying Capacity in Air
8 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 300 VAC
Operating Voltage (DC)
300 / 300 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x0,75 mm²
6.57 mm
26 Ω/km
63.7 kg/km
A
Current Carrying Capacity in Air
12 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x1 mm²
6.89 mm
19.5 Ω/km
73.49 kg/km
A
Current Carrying Capacity in Air
16 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x1,5 mm²
8.06 mm
13.3 Ω/km
102.4 kg/km
A
Current Carrying Capacity in Air
20 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x2,5 mm²
9.87 mm
7.98 Ω/km
158.06 kg/km
A
Current Carrying Capacity in Air
25 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
3x4 mm²
11.15 mm
4.95 Ω/km
216.79 kg/km
A
Current Carrying Capacity in Air
34 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x0,50 mm²
5.68 mm
39 Ω/km
49.75 kg/km
A
Current Carrying Capacity in Air
8 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 300 VAC
Operating Voltage (DC)
300 / 300 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x0,75 mm²
7.17 mm
26 Ω/km
78.05 kg/km
A
Current Carrying Capacity in Air
12 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x1 mm²
7.73 mm
19.5 Ω/km
94 kg/km
A
Current Carrying Capacity in Air
16 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x1,5 mm²
9.02 mm
13.3 Ω/km
130.57 kg/km
A
Current Carrying Capacity in Air
20 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x2,5 mm²
10.79 mm
7.98 Ω/km
195.83 kg/km
A
Current Carrying Capacity in Air
25 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
4x4 mm²
12.2 mm
4.95 Ω/km
270.31 kg/km
A
Current Carrying Capacity in Air
34 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
5x0,75 mm²
8.01 mm
26 Ω/km
97.58 kg/km
A
Current Carrying Capacity in Air
12 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
5x1 mm²
8.42 mm
19.5 Ω/km
113.23 kg/km
A
Current Carrying Capacity in Air
16 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
5x1,5 mm²
10.03 mm
13.3 Ω/km
162.13 kg/km
A
Current Carrying Capacity in Air
20 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
5x2,5 mm²
11.99 mm
7.98 Ω/km
242.79 kg/km
A
Current Carrying Capacity in Air
25 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
5x4 mm²
13.74 mm
4.95 Ω/km
341 kg/km
A
Current Carrying Capacity in Air
34 A
Conductor Structure
Fine Stranded Copper (Class 5)
Operating Voltage (AC)
300 / 500 VAC
Operating Voltage (DC)
300 / 500 VDC
Test Voltage (AC)
2000 - 2500 VAC
Insulation
PVC Resistant to -40°C Cold
Sheath
PVC Resistant to -40°C Cold
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
-40 - +70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS EN 50525 2-11
Flame Retardant Test
IEC 60332-1
Title Type Language
ARCTIC FLEXIBLE CABLE CE Kalite Sertifikası PDF
ARCTIC FLEXIBLE CABLE DOP Kalite Sertifikası PDF
ARCTIC FLEXIBLE CABLE TSE Kalite Sertifikası PDF
ARCTIC FLEXIBLE CABLE Ürün Ana Görseli PNG
ARCTIC FLEXIBLE CABLE Ürün Kataloğu PDF
ARCTIC FLEXIBLE CABLE Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1