YAVV / NAYY (SM)

PVC Insulated Aluminium Power Cables
Used as a fixed installation cable in damp places without mechanical stress, under and over plaster, inside cable ducts, wherever transmission reliability and electromagnetic protection are needed.

Twisted
Technical Specifications
Product
3x120 mm²
34.3 mm
0.253 Ω/km
1735.88 kg/km
A
Current Carrying Capacity in Air
216 A
Current Carrying Capacity in Ground
245 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x120+70 mm²
38.8 mm
0,253 / 0,443 Ω/km
2062.01 kg/km
A
Current Carrying Capacity in Air
216 A
Current Carrying Capacity in Ground
245 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x150 mm²
38.5 mm
0.206 Ω/km
2112.02 kg/km
A
Current Carrying Capacity in Air
252 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x150+70 mm²
42.8 mm
0,206 / 0,443 Ω/km
2442.14 kg/km
A
Current Carrying Capacity in Air
252 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x185 mm²
42.7 mm
0.164 Ω/km
2566.88 kg/km
A
Current Carrying Capacity in Air
289 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x185+95 mm²
47.6 mm
0,164 / 0,320 Ω/km
3008.26 kg/km
A
Current Carrying Capacity in Air
289 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x240 mm²
48.2 mm
0.125 Ω/km
3357.06 kg/km
A
Current Carrying Capacity in Air
338 A
Current Carrying Capacity in Ground
364 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x240+120 mm²
53.6 mm
0,125 / 0,253 Ω/km
3896.92 kg/km
A
Current Carrying Capacity in Air
338 A
Current Carrying Capacity in Ground
364 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x50 mm²
24.3 mm
0.641 Ω/km
826.92 kg/km
A
Current Carrying Capacity in Air
124 A
Current Carrying Capacity in Ground
144 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x50+25 mm²
27.6 mm
0,641 / 1,200 Ω/km
956.26 kg/km
A
Current Carrying Capacity in Air
124 A
Current Carrying Capacity in Ground
144 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x70 mm²
27.5 mm
0.443 Ω/km
1074.63 kg/km
A
Current Carrying Capacity in Air
158 A
Current Carrying Capacity in Ground
179 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x70+35 mm²
30.6 mm
0,443 / 0,868 Ω/km
1266.58 kg/km
A
Current Carrying Capacity in Air
158 A
Current Carrying Capacity in Ground
179 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x95 mm²
31.5 mm
0.32 Ω/km
1444.35 kg/km
A
Current Carrying Capacity in Air
190 A
Current Carrying Capacity in Ground
215 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
3x95+50 mm²
35.7 mm
0,320 / 0,641 Ω/km
1697.15 kg/km
A
Current Carrying Capacity in Air
190 A
Current Carrying Capacity in Ground
215 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x120 mm²
41.6 mm
0.253 Ω/km
2324.4 kg/km
A
Current Carrying Capacity in Air
216 A
Current Carrying Capacity in Ground
245 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x150 mm²
46.3 mm
0.206 Ω/km
2818.82 kg/km
A
Current Carrying Capacity in Air
252 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x185 mm²
51.4 mm
0.164 Ω/km
3422.48 kg/km
A
Current Carrying Capacity in Air
289 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x240 mm²
58.5 mm
0.125 Ω/km
4506.04 kg/km
A
Current Carrying Capacity in Air
338 A
Current Carrying Capacity in Ground
364 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x50 mm²
29 mm
0.641 Ω/km
1088.29 kg/km
A
Current Carrying Capacity in Air
124 A
Current Carrying Capacity in Ground
144 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x70 mm²
32.6 mm
0.443 Ω/km
1424.45 kg/km
A
Current Carrying Capacity in Air
158 A
Current Carrying Capacity in Ground
179 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
4x95 mm²
38 mm
0.32 Ω/km
1934.12 kg/km
A
Current Carrying Capacity in Air
190 A
Current Carrying Capacity in Ground
215 A
Conductor Structure
Sector Conducted Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Sheath
PVC
Current Type
AC
Layer Structure
PP Tape
Tape
Polypropylene
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
VDE 0276-603
Flame Retardant Test
IEC 60332-1
Title Type Language
YAVV / NAYY (SM) Ürün Ana Görseli PNG
YAVV / NAYY (SM) Ürün Kataloğu PDF
YAVV / NAYY (SM) Ürün Kesit Görseli JPG
How can we help you?