YAVV / NAYY

PVC Insulated Aluminium Power Cables
Used as a fixed installation cable in damp places without mechanical stress, under and over plaster, inside cable ducts, wherever transmission reliability and electromagnetic protection are needed.

Twisted
Technical Specifications
Product
1x120 mm²
18.9 mm
0.253 Ω/km
541.86 kg/km
A
Current Carrying Capacity in Air
239 A
Current Carrying Capacity in Ground
253 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x150 mm²
20.6 mm
0.206 Ω/km
648.6 kg/km
A
Current Carrying Capacity in Air
273 A
Current Carrying Capacity in Ground
284 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x16 mm²
8.9 mm
1.91 Ω/km
109.29 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x185 mm²
22.8 mm
0.164 Ω/km
793.32 kg/km
A
Current Carrying Capacity in Air
317 A
Current Carrying Capacity in Ground
322 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x240 mm²
25.8 mm
0.125 Ω/km
1023.2 kg/km
A
Current Carrying Capacity in Air
378 A
Current Carrying Capacity in Ground
375 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x25 mm²
10.5 mm
1.2 Ω/km
154.38 kg/km
A
Current Carrying Capacity in Air
87 A
Current Carrying Capacity in Ground
106 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x300 mm²
28.3 mm
0.1 Ω/km
1242.8 kg/km
A
Current Carrying Capacity in Air
437 A
Current Carrying Capacity in Ground
425 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x35 mm²
11.5 mm
0.868 Ω/km
188.71 kg/km
A
Current Carrying Capacity in Air
107 A
Current Carrying Capacity in Ground
127 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x400 mm²
31.7 mm
0.078 Ω/km
1575.6 kg/km
A
Current Carrying Capacity in Air
513 A
Current Carrying Capacity in Ground
487 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x50 mm²
13.2 mm
0.641 Ω/km
248.2 kg/km
A
Current Carrying Capacity in Air
131 A
Current Carrying Capacity in Ground
151 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x500 mm²
36.7 mm
0.061 Ω/km
2090 kg/km
A
Current Carrying Capacity in Air
600 A
Current Carrying Capacity in Ground
558 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x70 mm²
15 mm
0.443 Ω/km
330.22 kg/km
A
Current Carrying Capacity in Air
166 A
Current Carrying Capacity in Ground
185 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x95 mm²
17.1 mm
0.32 Ω/km
439.38 kg/km
A
Current Carrying Capacity in Air
205 A
Current Carrying Capacity in Ground
222 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x120 mm²
38.5 mm
0.253 Ω/km
2099.9 kg/km
A
Current Carrying Capacity in Air
216 A
Current Carrying Capacity in Ground
245 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x150 mm²
41.9 mm
0.206 Ω/km
2497.4 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x16 mm²
17.8 mm
1.91 Ω/km
425.94 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x185 mm²
46 mm
0.164 Ω/km
3008.6 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x25 mm²
21.6 mm
1.2 Ω/km
631.97 kg/km
A
Current Carrying Capacity in Air
82 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x35 mm²
23.6 mm
0.868 Ω/km
762.27 kg/km
A
Current Carrying Capacity in Air
100 A
Current Carrying Capacity in Ground
123 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x50 mm²
26.9 mm
0.641 Ω/km
992.93 kg/km
A
Current Carrying Capacity in Air
119 A
Current Carrying Capacity in Ground
144 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x70 mm²
30.7 mm
0.443 Ω/km
1309.4 kg/km
A
Current Carrying Capacity in Air
152 A
Current Carrying Capacity in Ground
179 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
2x95 mm²
35 mm
0.32 Ω/km
1722 kg/km
A
Current Carrying Capacity in Air
186 A
Current Carrying Capacity in Ground
215 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x120 mm²
41.2 mm
0.253 Ω/km
2448.5 kg/km
A
Current Carrying Capacity in Air
216 A
Current Carrying Capacity in Ground
245 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x120+70 mm²
41.2 mm
0,253 / 0,443 Ω/km
2444.1 kg/km
A
Current Carrying Capacity in Air
216 A
Current Carrying Capacity in Ground
245 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x150 mm²
45 mm
0.206 Ω/km
2932.3 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x150+70 mm²
45.2 mm
0,206 / 0,443 Ω/km
2887.6 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x16 mm²
18.9 mm
1.91 Ω/km
485.12 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x16+10 mm²
21.1 mm
1,91 / 3,08 Ω/km
581.83 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x185 mm²
49.5 mm
0.164 Ω/km
3541.9 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x185+95 mm²
51.1 mm
0,164 / 0,320 Ω/km
3653.7 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x240 mm²
56.1 mm
0.125 Ω/km
4566.9 kg/km
A
Current Carrying Capacity in Air
338 A
Current Carrying Capacity in Ground
364 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x240+120 mm²
57.4 mm
0,125 / 0,253 Ω/km
4747.5 kg/km
A
Current Carrying Capacity in Air
338 A
Current Carrying Capacity in Ground
364 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x25 mm²
22.3 mm
1.2 Ω/km
682 kg/km
A
Current Carrying Capacity in Air
82 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x25+16 mm²
23.1 mm
1,20 / 1,91 Ω/km
743.94 kg/km
A
Current Carrying Capacity in Air
82 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x300 mm²
61.6 mm
0.1 Ω/km
5538.5 kg/km
A
Current Carrying Capacity in Air
400 A
Current Carrying Capacity in Ground
419 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x300+150 mm²
65.5 mm
0,100 / 0,206 Ω/km
6239.3 kg/km
A
Current Carrying Capacity in Air
400 A
Current Carrying Capacity in Ground
419 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x35 mm²
25.1 mm
0.868 Ω/km
872.7 kg/km
A
Current Carrying Capacity in Air
100 A
Current Carrying Capacity in Ground
123 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x35+16 mm²
25.1 mm
0,868 / 1,91 Ω/km
904.89 kg/km
A
Current Carrying Capacity in Air
100 A
Current Carrying Capacity in Ground
123 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x400+185 mm²
71.9 mm
0,0778 / 0,164 Ω/km
7600.7 kg/km
A
Current Carrying Capacity in Air
472 A
Current Carrying Capacity in Ground
484 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x50 mm²
28.9 mm
0.641 Ω/km
1156.2 kg/km
A
Current Carrying Capacity in Air
119 A
Current Carrying Capacity in Ground
144 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x50+25 mm²
29.3 mm
0,641 / 1,20 Ω/km
1209.3 kg/km
A
Current Carrying Capacity in Air
119 A
Current Carrying Capacity in Ground
144 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x70 mm²
32.8 mm
0.443 Ω/km
1514.9 kg/km
A
Current Carrying Capacity in Air
152 A
Current Carrying Capacity in Ground
179 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x70+35 mm²
33.1 mm
0,443 / 0,868 Ω/km
1533.4 kg/km
A
Current Carrying Capacity in Air
152 A
Current Carrying Capacity in Ground
179 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x95 mm²
37.5 mm
0.32 Ω/km
2008.7 kg/km
A
Current Carrying Capacity in Air
186 A
Current Carrying Capacity in Ground
215 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x95+50 mm²
37.6 mm
0,320 / 0,641 Ω/km
1963.1 kg/km
A
Current Carrying Capacity in Air
186 A
Current Carrying Capacity in Ground
215 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x120 mm²
44.4 mm
0.253 Ω/km
2815.3 kg/km
A
Current Carrying Capacity in Air
216 A
Current Carrying Capacity in Ground
245 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x150 mm²
48.6 mm
0.206 Ω/km
3382.1 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x16 mm²
20.3 mm
1.91 Ω/km
553.21 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x185 mm²
53.9 mm
0.164 Ω/km
4087.7 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x240 mm²
61.2 mm
0.125 Ω/km
5372.9 kg/km
A
Current Carrying Capacity in Air
338 A
Current Carrying Capacity in Ground
364 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x25 mm²
24.1 mm
1.2 Ω/km
793.71 kg/km
A
Current Carrying Capacity in Air
82 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x300 mm²
68.7 mm
0.1 Ω/km
6771.3 kg/km
A
Current Carrying Capacity in Air
400 A
Current Carrying Capacity in Ground
419 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x35 mm²
26.4 mm
0.868 Ω/km
1013.9 kg/km
A
Current Carrying Capacity in Air
100 A
Current Carrying Capacity in Ground
123 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x400 mm²
76.9 mm
0.0778 Ω/km
8545.8 kg/km
A
Current Carrying Capacity in Air
472 A
Current Carrying Capacity in Ground
484 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x50 mm²
31 mm
0.641 Ω/km
1401.6 kg/km
A
Current Carrying Capacity in Air
119 A
Current Carrying Capacity in Ground
144 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x70 mm²
35.9 mm
0.443 Ω/km
1787.8 kg/km
A
Current Carrying Capacity in Air
152 A
Current Carrying Capacity in Ground
179 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
4x95 mm²
40.3 mm
0.32 Ω/km
2274.9 kg/km
A
Current Carrying Capacity in Air
186 A
Current Carrying Capacity in Ground
215 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x120 mm²
51.1 mm
0.253 Ω/km
3554.2 kg/km
A
Current Carrying Capacity in Air
216 A
Current Carrying Capacity in Ground
245 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x150 mm²
55.8 mm
0.206 Ω/km
4254.8 kg/km
A
Current Carrying Capacity in Air
246 A
Current Carrying Capacity in Ground
275 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x16 mm²
23.1 mm
1.91 Ω/km
691.83 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x185 mm²
61.3 mm
0.164 Ω/km
5119.9 kg/km
A
Current Carrying Capacity in Air
285 A
Current Carrying Capacity in Ground
313 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x240 mm²
69.7 mm
0.125 Ω/km
6635.3 kg/km
A
Current Carrying Capacity in Air
338 A
Current Carrying Capacity in Ground
364 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x25 mm²
27.5 mm
1.2 Ω/km
983.9 kg/km
A
Current Carrying Capacity in Air
82 A
Current Carrying Capacity in Ground
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x300 mm²
76.6 mm
0.1 Ω/km
8055.8 kg/km
A
Current Carrying Capacity in Air
400 A
Current Carrying Capacity in Ground
419 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x35 mm²
30.8 mm
0.868 Ω/km
1246.6 kg/km
A
Current Carrying Capacity in Air
100 A
Current Carrying Capacity in Ground
123 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x50 mm²
35.6 mm
0.641 Ω/km
1657.6 kg/km
A
Current Carrying Capacity in Air
119 A
Current Carrying Capacity in Ground
144 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x70 mm²
40.6 mm
0.443 Ω/km
2191.5 kg/km
A
Current Carrying Capacity in Air
152 A
Current Carrying Capacity in Ground
179 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
5x95 mm²
46.4 mm
0.32 Ω/km
2904 kg/km
A
Current Carrying Capacity in Air
186 A
Current Carrying Capacity in Ground
215 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE
Sheath
PVC
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Title Type Language
YAVV / NAYY Ürün Ana Görseli PNG
YAVV / NAYY Ürün Kataloğu PDF
YAVV / NAYY Ürün Kataloğu PDF
YAVV / NAYY Ürün Kesit Görseli JPG
YAVV / NAYY CE Kalite Sertifikası PDF
YAVV / NAYY DOP Kalite Sertifikası PDF
YAVV / NAYY TSE Kalite Sertifikası PDF
YAVV / NAYY VDE Kalite Sertifikası PDF
How can we help you?
Or
Adobestock 558884015 1