YAVCV / NAYCY

PVC Insulated Aluminium Power Cables with Concentric Copper Wire Screen
These cables with very low insulation losses are usually used underground. Connected to a concentric conductor protection switch and/or relay, they allow monitoring of impacts coming from outside to the cable. Used in power facilities where sudden load changes occur.

Twisted
Technical Specifications
Product
1x120/70 mm²
25.8 mm
0.253 Ω/km
1434.6 kg/km
A
Current Carrying Capacity in Air
247 A
Current Carrying Capacity in Ground
254 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x150/70 mm²
27.6 mm
0.206 Ω/km
1565 kg/km
A
Current Carrying Capacity in Air
286 A
Current Carrying Capacity in Ground
282 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x240/120 mm²
33.9 mm
0.125 Ω/km
2544.5 kg/km
A
Current Carrying Capacity in Air
377 A
Current Carrying Capacity in Ground
378 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x25/16 mm²
17.3 mm
1.2 Ω/km
480.03 kg/km
A
Current Carrying Capacity in Air
91 A
Current Carrying Capacity in Ground
108 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x35/16 mm²
18.3 mm
0.868 Ω/km
526.14 kg/km
A
Current Carrying Capacity in Air
112 A
Current Carrying Capacity in Ground
129 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x50/25 mm²
19.9 mm
0.641 Ω/km
690.48 kg/km
A
Current Carrying Capacity in Air
137 A
Current Carrying Capacity in Ground
153 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x70/35 mm²
21.5 mm
0.443 Ω/km
879.43 kg/km
A
Current Carrying Capacity in Air
173 A
Current Carrying Capacity in Ground
187 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
1x95/50 mm²
24 mm
0.32 Ω/km
1132.2 kg/km
A
Current Carrying Capacity in Air
212 A
Current Carrying Capacity in Ground
223 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x120/70 mm²
45 mm
0.253 Ω/km
3250 kg/km
A
Current Carrying Capacity in Air
224 A
Current Carrying Capacity in Ground
244 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x150/70 mm²
50 mm
0.206 Ω/km
3850 kg/km
A
Current Carrying Capacity in Air
256 A
Current Carrying Capacity in Ground
276 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x185/95 mm²
55 mm
0.164 Ω/km
4900 kg/km
A
Current Carrying Capacity in Air
292 A
Current Carrying Capacity in Ground
314 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x240/120 mm²
62.8 mm
0.125 Ω/km
5856.3 kg/km
A
Current Carrying Capacity in Air
340 A
Current Carrying Capacity in Ground
364 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x25/16 mm²
25 mm
1.2 Ω/km
950 kg/km
A
Current Carrying Capacity in Air
84 A
Current Carrying Capacity in Ground
100 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x300/150 mm²
70.4 mm
0.1 Ω/km
7366.5 kg/km
A
Current Carrying Capacity in Air
380 A
Current Carrying Capacity in Ground
414 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x35/16 mm²
27.5 mm
0.868 Ω/km
1100 kg/km
A
Current Carrying Capacity in Air
102 A
Current Carrying Capacity in Ground
118 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x50/25 mm²
33.1 mm
0.641 Ω/km
1436.4 kg/km
A
Current Carrying Capacity in Air
126 A
Current Carrying Capacity in Ground
144 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x70/35 mm²
36 mm
0.443 Ω/km
2000 kg/km
A
Current Carrying Capacity in Air
159 A
Current Carrying Capacity in Ground
180 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
3x95/50 mm²
41.5 mm
0.32 Ω/km
2650 kg/km
A
Current Carrying Capacity in Air
190 A
Current Carrying Capacity in Ground
211 A
Conductor Structure
Stranded Aluminum (Class 2)
Operating Voltage (AC)
600 / 1000 VAC
Operating Voltage (DC)
600 / 1000 VDC
Test Voltage (AC)
4000 VAC
Insulation
PVC
Filler
PE Filler / PVC Inner Sheath
Sheath
PVC
Current Type
AC
Layer Structure
Concentric Copper Conductor, Copper Tape, PP Tape
Tape
Concentric Copper Wire & Copper Tape & Polypropylene
Minimum Bending Radius
15 x D mm
Temperature Range
70 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
160 °C
Standard
TS IEC 60502-1
Flame Retardant Test
IEC 60332-1
Title Type Language
YAVCV / NAYCY Ürün Ana Görseli PNG
YAVCV / NAYCY Ürün Kataloğu PDF
YAVCV / NAYCY Ürün Kesit Görseli JPG
How can we help you?
Or
Adobestock 558884015 1