ACSR (IEC)

Steel Reinforced Aluminium Conductors
Manufactured according to TS EN 50182 standards from aluminum wires and zinc-coated steel wires. Conductors are stranded concentrically in seven or more layers. If the conductor consists of multiple layers, adjacent layers are stranded in opposite directions. Production can be made according to DIN, BS, ASTM, NF, CSA, EN standards upon request. Used in medium and high voltage transmission lines.

Twisted
Technical Specifications
Product
100 (96 mm²)
13.5 mm
0.2868 Ω/km
368.6 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/4,51 ad-mm
Number and Wire Diameter (Conductor)
6/4,51 ad-mm
Steel Wire Cross-Section
16 mm² mm²
Current Type
AC
Actual Code (New Standard)
100
Standard
IEC 61089
1000 (989 mm²)
41.8 mm
0.0289 Ω/km
3016 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,79 ad-mm
Number and Wire Diameter (Conductor)
72/4,18 ad-mm
Steel Wire Cross-Section
42,7 mm² mm²
Current Type
AC
Actual Code (New Standard)
1000
Standard
IEC 61089
1120 (1098 mm²)
46.8 mm
0.0258 Ω/km
3628.4 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,45 ad-mm
Number and Wire Diameter (Conductor)
84/4,08 ad-mm
Steel Wire Cross-Section
89,4 mm² mm²
Current Type
AC
Actual Code (New Standard)
1120
Standard
IEC 61089
1120 (1108 mm²)
44.33 mm
0.0258 Ω/km
3372.6 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/1,77 ad-mm
Number and Wire Diameter (Conductor)
72/4,43 ad-mm
Steel Wire Cross-Section
46,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
1120
Standard
IEC 61089
125 (120 mm²)
15.4 mm
0.2308 Ω/km
460.8 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,89 ad-mm
Number and Wire Diameter (Conductor)
26/2,43 ad-mm
Steel Wire Cross-Section
19,6 mm² mm²
Current Type
AC
Actual Code (New Standard)
125
Standard
IEC 61089
125 (123 mm²)
14.8 mm
0.2304 Ω/km
384.3 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,95 ad-mm
Number and Wire Diameter (Conductor)
18/2,95 ad-mm
Steel Wire Cross-Section
6,85 mm² mm²
Current Type
AC
Actual Code (New Standard)
125
Standard
IEC 61089
1250 (1225 mm²)
47.4 mm
0.0231 Ω/km
4049.5 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,59 ad-mm
Number and Wire Diameter (Conductor)
84/4,31 ad-mm
Steel Wire Cross-Section
99,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
1250
Standard
IEC 61089
1250 (1237 mm²)
46.8 mm
0.0231 Ω/km
3764.1 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/1,87 ad-mm
Number and Wire Diameter (Conductor)
72/4,68 ad-mm
Steel Wire Cross-Section
52,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
1250
Standard
IEC 61089
16 (15 mm²)
5.43 mm
17.923 Ω/km
59 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/1,81 ad-mm
Number and Wire Diameter (Conductor)
6/1,81 ad-mm
Steel Wire Cross-Section
2,56 mm² mm²
Current Type
AC
Actual Code (New Standard)
16
Standard
IEC 61089
160 (154 mm²)
17.4 mm
0.1803 Ω/km
589.9 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,13 ad-mm
Number and Wire Diameter (Conductor)
26/2,74 ad-mm
Steel Wire Cross-Section
25 mm² mm²
Current Type
AC
Actual Code (New Standard)
160
Standard
IEC 61089
160 (158 mm²)
16.7 mm
0.18 Ω/km
491.9 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,34 ad-mm
Number and Wire Diameter (Conductor)
18/3,34 ad-mm
Steel Wire Cross-Section
8,77 mm² mm²
Current Type
AC
Actual Code (New Standard)
160
Standard
IEC 61089
200 (192 mm²)
19.4 mm
0.1443 Ω/km
737.2 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,39 ad-mm
Number and Wire Diameter (Conductor)
26/3,07 ad-mm
Steel Wire Cross-Section
31,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
200
Standard
IEC 61089
200 (197 mm²)
18.7 mm
0.144 Ω/km
614.9 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,74 ad-mm
Number and Wire Diameter (Conductor)
18/3,74 ad-mm
Steel Wire Cross-Section
10,96 mm² mm²
Current Type
AC
Actual Code (New Standard)
200
Standard
IEC 61089
25 (24 mm²)
6.78 mm
11.471 Ω/km
92.1 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,26 ad-mm
Number and Wire Diameter (Conductor)
6/2,26 ad-mm
Steel Wire Cross-Section
4 mm² mm²
Current Type
AC
Actual Code (New Standard)
25
Standard
IEC 61089
250 (240 mm²)
21.7 mm
0.1154 Ω/km
921.5 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,67 ad-mm
Number and Wire Diameter (Conductor)
26/3,43 ad-mm
Steel Wire Cross-Section
39,1 mm² mm²
Current Type
AC
Actual Code (New Standard)
250
Standard
IEC 61089
250 (244 mm²)
21.3 mm
0.1153 Ω/km
830.9 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,09 ad-mm
Number and Wire Diameter (Conductor)
22/3,76 ad-mm
Steel Wire Cross-Section
24 mm² mm²
Current Type
AC
Actual Code (New Standard)
250
Standard
IEC 61089
315 (303 mm²)
24.4 mm
0.0916 Ω/km
11.611 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,02 ad-mm
Number and Wire Diameter (Conductor)
26/3,85 ad-mm
Steel Wire Cross-Section
49,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
315
Standard
IEC 61089
315 (310 mm²)
23.7 mm
0.0917 Ω/km
996.4 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,97 ad-mm
Number and Wire Diameter (Conductor)
45/2,96 ad-mm
Steel Wire Cross-Section
21,4 mm² mm²
Current Type
AC
Actual Code (New Standard)
315
Standard
IEC 61089
40 (38 mm²)
8.55 mm
0.7169 Ω/km
147.4 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,85 ad-mm
Number and Wire Diameter (Conductor)
6/2,85 ad-mm
Steel Wire Cross-Section
6,4 mm² mm²
Current Type
AC
Actual Code (New Standard)
40
Standard
IEC 61089
400 (387 mm²)
27.2 mm
0.0723 Ω/km
1402.9 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,02 ad-mm
Number and Wire Diameter (Conductor)
54/3,02 ad-mm
Steel Wire Cross-Section
50,2 mm² mm²
Current Type
AC
Actual Code (New Standard)
400
Standard
IEC 61089
400 (393 mm²)
26.7 mm
0.0722 Ω/km
1265.3 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,22 ad-mm
Number and Wire Diameter (Conductor)
45/3,34 ad-mm
Steel Wire Cross-Section
27,2 mm² mm²
Current Type
AC
Actual Code (New Standard)
400
Standard
IEC 61089
450 (436 mm²)
28.9 mm
0.0642 Ω/km
1578.2 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,21 ad-mm
Number and Wire Diameter (Conductor)
54/3,21 ad-mm
Steel Wire Cross-Section
56,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
450
Standard
IEC 61089
450 (442 mm²)
28.3 mm
0.0642 Ω/km
1423.4 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,36 ad-mm
Number and Wire Diameter (Conductor)
45/3,54 ad-mm
Steel Wire Cross-Section
30,6 mm² mm²
Current Type
AC
Actual Code (New Standard)
450
Standard
IEC 61089
500 (484 mm²)
30.4 mm
0.0578 Ω/km
1753.6 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,38 ad-mm
Number and Wire Diameter (Conductor)
54/3,38 ad-mm
Steel Wire Cross-Section
62,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
500
Standard
IEC 61089
500 (492 mm²)
29.8 mm
0.0578 Ω/km
1581.6 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,49 ad-mm
Number and Wire Diameter (Conductor)
45/3,73 ad-mm
Steel Wire Cross-Section
34 mm² mm²
Current Type
AC
Actual Code (New Standard)
500
Standard
IEC 61089
560 (543 mm²)
32.2 mm
0.0516 Ω/km
1956.3 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,15 ad-mm
Number and Wire Diameter (Conductor)
54/3,58 ad-mm
Steel Wire Cross-Section
68,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
560
Standard
IEC 61089
560 (550 mm²)
31.6 mm
0.0516 Ω/km
1771.4 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,63 ad-mm
Number and Wire Diameter (Conductor)
45/3,95 ad-mm
Steel Wire Cross-Section
38,1 mm² mm²
Current Type
AC
Actual Code (New Standard)
560
Standard
IEC 61089
63 (60 mm²)
10.7 mm
0.4552 Ω/km
232.2 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,58 ad-mm
Number and Wire Diameter (Conductor)
6/3,58 ad-mm
Steel Wire Cross-Section
10,08 mm² mm²
Current Type
AC
Actual Code (New Standard)
63
Standard
IEC 61089
630 (611 mm²)
34.2 mm
0.0459 Ω/km
2200.9 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,28 ad-mm
Number and Wire Diameter (Conductor)
54/3,79 ad-mm
Steel Wire Cross-Section
77,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
630
Standard
IEC 61089
630 (619 mm²)
33.5 mm
0.0458 Ω/km
1992.8 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,79 ad-mm
Number and Wire Diameter (Conductor)
45/4,19 ad-mm
Steel Wire Cross-Section
42,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
630
Standard
IEC 61089
710 (688 mm²)
36.3 mm
0.0407 Ω/km
2480.3 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,42 ad-mm
Number and Wire Diameter (Conductor)
54/4,03 ad-mm
Steel Wire Cross-Section
87,2 mm² mm²
Current Type
AC
Actual Code (New Standard)
710
Standard
IEC 61089
710 (698 mm²)
35.6 mm
0.0407 Ω/km
2245.8 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,96 ad-mm
Number and Wire Diameter (Conductor)
45/4,44 ad-mm
Steel Wire Cross-Section
48,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
710
Standard
IEC 61089
800 (775 mm²)
38.5 mm
0.0361 Ω/km
2794.7 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,57 ad-mm
Number and Wire Diameter (Conductor)
54/4,28 ad-mm
Steel Wire Cross-Section
98,2 mm² mm²
Current Type
AC
Actual Code (New Standard)
800
Standard
IEC 61089
800 (784 mm²)
37.9 mm
0.0362 Ω/km
2598.9 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,45 ad-mm
Number and Wire Diameter (Conductor)
84/3,45 ad-mm
Steel Wire Cross-Section
65,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
800
Standard
IEC 61089
800 (791 mm²)
37.4 mm
0.0361 Ω/km
2412.8 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,49 ad-mm
Number and Wire Diameter (Conductor)
72/3,74 ad-mm
Steel Wire Cross-Section
34,2 mm² mm²
Current Type
AC
Actual Code (New Standard)
800
Standard
IEC 61089
900 (882 mm²)
40.2 mm
0.0321 Ω/km
2923.8 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,66 ad-mm
Number and Wire Diameter (Conductor)
84/3,66 ad-mm
Steel Wire Cross-Section
73,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
900
Standard
IEC 61089
900 (890 mm²)
39.7 mm
0.0321 Ω/km
2714.4 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,65 ad-mm
Number and Wire Diameter (Conductor)
72/3,97 ad-mm
Steel Wire Cross-Section
38,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
900
Standard
IEC 61089
Title Type Language
ACSR (IEC) Ürün Alternatif Görseli PNG
ACSR (IEC) Ürün Ana Görseli PNG
ACSR (IEC) Ürün Kataloğu PDF
ACSR (IEC) Ürün Kataloğu PDF
ACSR (IEC) Ürün Kataloğu PDF
ACSR (IEC) Ürün Kataloğu PDF
ACSR (IEC) Ürün Kataloğu PDF
ACSR (IEC) Ürün Kesit Görseli JPG
ACSR (IEC) CE Kalite Sertifikası PDF
ACSR (IEC) GOST Kalite Sertifikası PDF
ACSR (IEC) TSE Kalite Sertifikası PDF
How can we help you?
Or
Adobestock 558884015 1