ACSR (GOST)

Steel Reinforced Aluminium Conductors
Manufactured according to TS EN 50182 standards from aluminum wires and zinc-coated steel wires. Conductors are stranded concentrically in seven or more layers. If the conductor consists of multiple layers, adjacent layers are stranded in opposite directions. Production can be made according to DIN, BS, ASTM, NF, CSA, EN standards upon request. Used in medium and high voltage transmission lines.

Twisted
Technical Specifications
Product
10 / 1,8 (10,6 mm²)
4.5 mm
27.064 Ω/km
42.7 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/1,50 ad-mm
Number and Wire Diameter (Conductor)
6/1,50 ad-mm
Steel Wire Cross-Section
1,77 mm² mm²
Current Type
AC
Actual Code (New Standard)
10 / 1,8
Standard
GOST 839-80
100 / 16,7 (100,15 mm²)
13.82 mm
0.7868 Ω/km
403.2 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/4,61 ad-mm
Number and Wire Diameter (Conductor)
6/4,61 ad-mm
Steel Wire Cross-Section
16,69 mm² mm²
Current Type
AC
Actual Code (New Standard)
100 / 16,7
Standard
GOST 839-80
120 / 19 (117,62 mm²)
15.2 mm
0.244 Ω/km
471 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,85 ad-mm
Number and Wire Diameter (Conductor)
26/2,40 ad-mm
Steel Wire Cross-Section
18,82 mm² mm²
Current Type
AC
Actual Code (New Standard)
120 / 19
Standard
GOST 839-80
120 / 27 (114,04 mm²)
15.4 mm
0.2531 Ω/km
528 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,20 ad-mm
Number and Wire Diameter (Conductor)
30/2,20 ad-mm
Steel Wire Cross-Section
26,61 mm² mm²
Current Type
AC
Actual Code (New Standard)
120 / 27
Standard
GOST 839-80
125 / 20,4 (124,58 mm²)
15.67 mm
0.2308 Ω/km
503.5 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,92 ad-mm
Number and Wire Diameter (Conductor)
26/2,47 ad-mm
Steel Wire Cross-Section
20,27 mm² mm²
Current Type
AC
Actual Code (New Standard)
125 / 20,4
Standard
GOST 839-80
125 / 6,9 (124,7 mm²)
14.67 mm
0.2304 Ω/km
397.9 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,97 ad-mm
Number and Wire Diameter (Conductor)
18/2,97 ad-mm
Steel Wire Cross-Section
6,93 mm² mm²
Current Type
AC
Actual Code (New Standard)
125 / 6,9
Standard
GOST 839-80
150 / 19 (147,78 mm²)
16.8 mm
0.2046 Ω/km
554 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,85 ad-mm
Number and Wire Diameter (Conductor)
24/2,80 ad-mm
Steel Wire Cross-Section
18,82 mm² mm²
Current Type
AC
Actual Code (New Standard)
150 / 19
Standard
GOST 839-80
150 / 24 (148,86 mm²)
17.1 mm
0.2049 Ω/km
599 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,10 ad-mm
Number and Wire Diameter (Conductor)
26/2,70 ad-mm
Steel Wire Cross-Section
24,25 mm² mm²
Current Type
AC
Actual Code (New Standard)
150 / 24
Standard
GOST 839-80
150 / 34 (147,26 mm²)
17.5 mm
0.2061 Ω/km
675 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,50 ad-mm
Number and Wire Diameter (Conductor)
30/2,50 ad-mm
Steel Wire Cross-Section
34,36 mm² mm²
Current Type
AC
Actual Code (New Standard)
150 / 34
Standard
GOST 839-80
16 / 2,7 (16,13 mm²)
5.6 mm
17.818 Ω/km
64.9 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/1,85 ad-mm
Number and Wire Diameter (Conductor)
6/1,85 ad-mm
Steel Wire Cross-Section
2,69 mm² mm²
Current Type
AC
Actual Code (New Standard)
16 / 2,7
Standard
GOST 839-80
160 / 26,1 (160,1 mm²)
17.74 mm
0.1803 Ω/km
644.5 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,18 ad-mm
Number and Wire Diameter (Conductor)
26/2,80 ad-mm
Steel Wire Cross-Section
26,13 mm² mm²
Current Type
AC
Actual Code (New Standard)
160 / 26,1
Standard
GOST 839-80
160 / 8,9 (159,6 mm²)
16.82 mm
0.18 Ω/km
509.4 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,36 ad-mm
Number and Wire Diameter (Conductor)
18/3,36 ad-mm
Steel Wire Cross-Section
8,87 mm² mm²
Current Type
AC
Actual Code (New Standard)
160 / 8,9
Standard
GOST 839-80
185 / 128 (187,04 mm²)
23.1 mm
0.1543 Ω/km
1525 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
37/2,10 ad-mm
Number and Wire Diameter (Conductor)
54/2,10 ad-mm
Steel Wire Cross-Section
128,15 mm² mm²
Current Type
AC
Actual Code (New Standard)
185 / 128
Standard
GOST 839-80
185 / 24 (187,04 mm²)
18.9 mm
0.154 Ω/km
705 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,10 ad-mm
Number and Wire Diameter (Conductor)
24/3,15 ad-mm
Steel Wire Cross-Section
24,25 mm² mm²
Current Type
AC
Actual Code (New Standard)
185 / 24
Standard
GOST 839-80
185 / 29 (181,34 mm²)
18.8 mm
0.1591 Ω/km
728 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,30 ad-mm
Number and Wire Diameter (Conductor)
26/2,98 ad-mm
Steel Wire Cross-Section
29,08 mm² mm²
Current Type
AC
Actual Code (New Standard)
185 / 29
Standard
GOST 839-80
185 / 43 (184,73 mm²)
19.6 mm
0.1559 Ω/km
846 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,80 ad-mm
Number and Wire Diameter (Conductor)
30/2,80 ad-mm
Steel Wire Cross-Section
43,1 mm² mm²
Current Type
AC
Actual Code (New Standard)
185 / 43
Standard
GOST 839-80
200 / 11,1 (199,87 mm²)
18.81 mm
0.144 Ω/km
636.7 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,76 ad-mm
Number and Wire Diameter (Conductor)
18/3,76 ad-mm
Steel Wire Cross-Section
11,1 mm² mm²
Current Type
AC
Actual Code (New Standard)
200 / 11,1
Standard
GOST 839-80
200 / 32,6 (200,06 mm²)
19.82 mm
0.1442 Ω/km
805.6 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,43 ad-mm
Number and Wire Diameter (Conductor)
26/3,13 ad-mm
Steel Wire Cross-Section
32,46 mm² mm²
Current Type
AC
Actual Code (New Standard)
200 / 32,6
Standard
GOST 839-80
205 / 27 (205,27 mm²)
19.8 mm
0.1407 Ω/km
846 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,20 ad-mm
Number and Wire Diameter (Conductor)
24/3,30 ad-mm
Steel Wire Cross-Section
26,61 mm² mm²
Current Type
AC
Actual Code (New Standard)
205 / 27
Standard
GOST 839-80
240 / 32 (244,29 mm²)
21.6 mm
0.1182 Ω/km
921 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,40 ad-mm
Number and Wire Diameter (Conductor)
24/3,60 ad-mm
Steel Wire Cross-Section
31,67 mm² mm²
Current Type
AC
Actual Code (New Standard)
240 / 32
Standard
GOST 839-80
240 / 39 (236,06 mm²)
21.6 mm
0.1222 Ω/km
952 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,65 ad-mm
Number and Wire Diameter (Conductor)
26/3,40 ad-mm
Steel Wire Cross-Section
38,61 mm² mm²
Current Type
AC
Actual Code (New Standard)
240 / 39
Standard
GOST 839-80
240 / 56 (241,27 mm²)
22.4 mm
0.1197 Ω/km
1106 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,20 ad-mm
Number and Wire Diameter (Conductor)
30/3,20 ad-mm
Steel Wire Cross-Section
56,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
240 / 56
Standard
GOST 839-80
25 / 4,2 (24,93 mm²)
6.9 mm
11.521 Ω/km
100.3 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,30 ad-mm
Number and Wire Diameter (Conductor)
6/2,30 ad-mm
Steel Wire Cross-Section
4,15 mm² mm²
Current Type
AC
Actual Code (New Standard)
25 / 4,2
Standard
GOST 839-80
300 / 204 (297,84 mm²)
29.2 mm
0.0968 Ω/km
2428 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
37/2,65 ad-mm
Number and Wire Diameter (Conductor)
54/2,65 ad-mm
Steel Wire Cross-Section
204,07 mm² mm²
Current Type
AC
Actual Code (New Standard)
300 / 204
Standard
GOST 839-80
300 / 39 (301,59 mm²)
24 mm
0.0958 Ω/km
1132 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,65 ad-mm
Number and Wire Diameter (Conductor)
24/4,00 ad-mm
Steel Wire Cross-Section
38,61 mm² mm²
Current Type
AC
Actual Code (New Standard)
300 / 39
Standard
GOST 839-80
300 / 48 (294,87 mm²)
24.1 mm
0.0978 Ω/km
1186 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,95 ad-mm
Number and Wire Diameter (Conductor)
26/3,80 ad-mm
Steel Wire Cross-Section
47,84 mm² mm²
Current Type
AC
Actual Code (New Standard)
300 / 48
Standard
GOST 839-80
300 / 66 (288,63 mm²)
24.5 mm
0.1 Ω/km
1313 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,10 ad-mm
Number and Wire Diameter (Conductor)
30/3,50 ad-mm
Steel Wire Cross-Section
65,81 mm² mm²
Current Type
AC
Actual Code (New Standard)
300 / 66
Standard
GOST 839-80
300 / 67 (288,63 mm²)
24.5 mm
0.1 Ω/km
1323 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,50 ad-mm
Number and Wire Diameter (Conductor)
30/3,50 ad-mm
Steel Wire Cross-Section
67,35 mm² mm²
Current Type
AC
Actual Code (New Standard)
300 / 67
Standard
GOST 839-80
315 / 21,8 (315,97 mm²)
23.83 mm
0.0917 Ω/km
1039.2 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,99 ad-mm
Number and Wire Diameter (Conductor)
45/2,99 ad-mm
Steel Wire Cross-Section
21,77 mm² mm²
Current Type
AC
Actual Code (New Standard)
315 / 21,8
Standard
GOST 839-80
315 / 51,3 (315,39 mm²)
24.87 mm
0.0916 Ω/km
1268.9 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,05 ad-mm
Number and Wire Diameter (Conductor)
26/3,93 ad-mm
Steel Wire Cross-Section
51,14 mm² mm²
Current Type
AC
Actual Code (New Standard)
315 / 51,3
Standard
GOST 839-80
330 / 30 (334,78 mm²)
24.8 mm
0.0861 Ω/km
1152 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,30 ad-mm
Number and Wire Diameter (Conductor)
48/2,98 ad-mm
Steel Wire Cross-Section
29,08 mm² mm²
Current Type
AC
Actual Code (New Standard)
330 / 30
Standard
GOST 839-80
330 / 43 (332,51 mm²)
25.2 mm
0.0869 Ω/km
1255 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,80 ad-mm
Number and Wire Diameter (Conductor)
54/2,80 ad-mm
Steel Wire Cross-Section
43,1 mm² mm²
Current Type
AC
Actual Code (New Standard)
330 / 43
Standard
GOST 839-80
35 / 6,2 (36,95 mm²)
8.4 mm
0.7774 Ω/km
148 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,80 ad-mm
Number and Wire Diameter (Conductor)
6/2,80 ad-mm
Steel Wire Cross-Section
6,16 mm² mm²
Current Type
AC
Actual Code (New Standard)
35 / 6,2
Standard
GOST 839-80
40 / 6,7 (39,91 mm²)
8.74 mm
0.7172 Ω/km
161.3 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,91 ad-mm
Number and Wire Diameter (Conductor)
6/2,91 ad-mm
Steel Wire Cross-Section
6,65 mm² mm²
Current Type
AC
Actual Code (New Standard)
40 / 6,7
Standard
GOST 839-80
400 / 18 (381,33 mm²)
26 mm
0.0758 Ω/km
1199 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,85 ad-mm
Number and Wire Diameter (Conductor)
42/3,40 ad-mm
Steel Wire Cross-Section
18,82 mm² mm²
Current Type
AC
Actual Code (New Standard)
400 / 18
Standard
GOST 839-80
400 / 27,7 (399,01 mm²)
26.91 mm
0.0722 Ω/km
1319.7 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,24 ad-mm
Number and Wire Diameter (Conductor)
45/3,36 ad-mm
Steel Wire Cross-Section
27,59 mm² mm²
Current Type
AC
Actual Code (New Standard)
400 / 27,7
Standard
GOST 839-80
400 / 51 (394,53 mm²)
27.5 mm
0.0733 Ω/km
1490 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,05 ad-mm
Number and Wire Diameter (Conductor)
54/3,05 ad-mm
Steel Wire Cross-Section
51,14 mm² mm²
Current Type
AC
Actual Code (New Standard)
400 / 51
Standard
GOST 839-80
400 / 51,9 (399,73 mm²)
27.64 mm
0.0722 Ω/km
1509.7 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,07 ad-mm
Number and Wire Diameter (Conductor)
54/3,07 ad-mm
Steel Wire Cross-Section
51,82 mm² mm²
Current Type
AC
Actual Code (New Standard)
400 / 51,9
Standard
GOST 839-80
400 / 64 (389,97 mm²)
27.7 mm
0.0741 Ω/km
1572 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,40 ad-mm
Number and Wire Diameter (Conductor)
26/4,37 ad-mm
Steel Wire Cross-Section
63,55 mm² mm²
Current Type
AC
Actual Code (New Standard)
400 / 64
Standard
GOST 839-80
400 / 93 (405,8 mm²)
29.1 mm
0.0711 Ω/km
1851 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,50 ad-mm
Number and Wire Diameter (Conductor)
30/4,15 ad-mm
Steel Wire Cross-Section
93,27 mm² mm²
Current Type
AC
Actual Code (New Standard)
400 / 93
Standard
GOST 839-80
450 / 31,1 (450,44 mm²)
28.55 mm
0.0646 Ω/km
1484.6 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,38 ad-mm
Number and Wire Diameter (Conductor)
45/3,57 ad-mm
Steel Wire Cross-Section
31,14 mm² mm²
Current Type
AC
Actual Code (New Standard)
450 / 31,1
Standard
GOST 839-80
450 / 56 (434,29 mm²)
28.8 mm
0.0666 Ω/km
1640 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,20 ad-mm
Number and Wire Diameter (Conductor)
54/3,20 ad-mm
Steel Wire Cross-Section
56,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
450 / 56
Standard
GOST 839-80
450 / 58,3 (450,73 mm²)
29.32 mm
0.0642 Ω/km
1698.4 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,26 ad-mm
Number and Wire Diameter (Conductor)
54/3,26 ad-mm
Steel Wire Cross-Section
58,43 mm² mm²
Current Type
AC
Actual Code (New Standard)
450 / 58,3
Standard
GOST 839-80
50 / 8,0 (48,25 mm²)
9.6 mm
0.5951 Ω/km
195 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,20 ad-mm
Number and Wire Diameter (Conductor)
6/3,20 ad-mm
Steel Wire Cross-Section
8,04 mm² mm²
Current Type
AC
Actual Code (New Standard)
50 / 8,0
Standard
GOST 839-80
500 / 26 (501,73 mm²)
30 mm
0.0575 Ω/km
1592 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,20 ad-mm
Number and Wire Diameter (Conductor)
42/3,90 ad-mm
Steel Wire Cross-Section
26,61 mm² mm²
Current Type
AC
Actual Code (New Standard)
500 / 26
Standard
GOST 839-80
500 / 34,6 (499,67 mm²)
30.09 mm
0.0577 Ω/km
1649.6 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,51 ad-mm
Number and Wire Diameter (Conductor)
45/3,76 ad-mm
Steel Wire Cross-Section
34,64 mm² mm²
Current Type
AC
Actual Code (New Standard)
500 / 34,6
Standard
GOST 839-80
500 / 64 (490,28 mm²)
30.6 mm
0.0588 Ω/km
1852 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,40 ad-mm
Number and Wire Diameter (Conductor)
54/3,40 ad-mm
Steel Wire Cross-Section
63,55 mm² mm²
Current Type
AC
Actual Code (New Standard)
500 / 64
Standard
GOST 839-80
500 / 64,8 (498,97 mm²)
30.9 mm
0.0578 Ω/km
1887.1 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,43 ad-mm
Number and Wire Diameter (Conductor)
54/3,43 ad-mm
Steel Wire Cross-Section
64,68 mm² mm²
Current Type
AC
Actual Code (New Standard)
500 / 64,8
Standard
GOST 839-80
550 / 71 (549,65 mm²)
32.4 mm
0.0526 Ω/km
2076 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,60 ad-mm
Number and Wire Diameter (Conductor)
54/3,60 ad-mm
Steel Wire Cross-Section
71,25 mm² mm²
Current Type
AC
Actual Code (New Standard)
550 / 71
Standard
GOST 839-80
560 / 38,7 (559,85 mm²)
31.84 mm
0.0515 Ω/km
1847.5 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,65 ad-mm
Number and Wire Diameter (Conductor)
45/3,98 ad-mm
Steel Wire Cross-Section
38,61 mm² mm²
Current Type
AC
Actual Code (New Standard)
560 / 38,7
Standard
GOST 839-80
560 / 70,9 (558,85 mm²)
32.7 mm
0.0516 Ω/km
2102.2 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,18 ad-mm
Number and Wire Diameter (Conductor)
54/3,63 ad-mm
Steel Wire Cross-Section
70,92 mm² mm²
Current Type
AC
Actual Code (New Standard)
560 / 70,9
Standard
GOST 839-80
600 / 72 (580,61 mm²)
33.2 mm
0.0498 Ω/km
2170 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,20 ad-mm
Number and Wire Diameter (Conductor)
54/3,70 ad-mm
Steel Wire Cross-Section
72,23 mm² mm²
Current Type
AC
Actual Code (New Standard)
600 / 72
Standard
GOST 839-80
63 / 10,5 (63,13 mm²)
10.97 mm
0.4553 Ω/km
254 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,66 ad-mm
Number and Wire Diameter (Conductor)
6/3,66 ad-mm
Steel Wire Cross-Section
10,52 mm² mm²
Current Type
AC
Actual Code (New Standard)
63 / 10,5
Standard
GOST 839-80
630 / 43,6 (629,4 mm²)
33.79 mm
0.0458 Ω/km
2078.5 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,81 ad-mm
Number and Wire Diameter (Conductor)
45/4,22 ad-mm
Steel Wire Cross-Section
43,41 mm² mm²
Current Type
AC
Actual Code (New Standard)
630 / 43,6
Standard
GOST 839-80
630 / 79,8 (628,65 mm²)
34.69 mm
0.0459 Ω/km
2365 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,31 ad-mm
Number and Wire Diameter (Conductor)
54/3,85 ad-mm
Steel Wire Cross-Section
79,63 mm² mm²
Current Type
AC
Actual Code (New Standard)
630 / 79,8
Standard
GOST 839-80
70 / 11 (68,05 mm²)
11.4 mm
0.4218 Ω/km
276 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,80 ad-mm
Number and Wire Diameter (Conductor)
6/3,80 ad-mm
Steel Wire Cross-Section
11,34 mm² mm²
Current Type
AC
Actual Code (New Standard)
70 / 11
Standard
GOST 839-80
70 / 72 (68,42 mm²)
15.4 mm
0.4194 Ω/km
755 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,20 ad-mm
Number and Wire Diameter (Conductor)
18/2,20 ad-mm
Steel Wire Cross-Section
72,23 mm² mm²
Current Type
AC
Actual Code (New Standard)
70 / 72
Standard
GOST 839-80
710 / 49,1 (709,35 mm²)
35.86 mm
0.0406 Ω/km
2342.4 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,99 ad-mm
Number and Wire Diameter (Conductor)
45/4,48 ad-mm
Steel Wire Cross-Section
49,15 mm² mm²
Current Type
AC
Actual Code (New Standard)
710 / 49,1
Standard
GOST 839-80
710 / 89,9 (709,47 mm²)
36.82 mm
0.0407 Ω/km
2665.3 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,45 ad-mm
Number and Wire Diameter (Conductor)
54/4,09 ad-mm
Steel Wire Cross-Section
89,57 mm² mm²
Current Type
AC
Actual Code (New Standard)
710 / 89,9
Standard
GOST 839-80
800 / 101,3 (798,85 mm²)
39.09 mm
0.0361 Ω/km
3003.2 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,61 ad-mm
Number and Wire Diameter (Conductor)
54/4,34 ad-mm
Steel Wire Cross-Section
101,65 mm² mm²
Current Type
AC
Actual Code (New Standard)
800 / 101,3
Standard
GOST 839-80
95 / 141 (91,23 mm²)
19.8 mm
0.3146 Ω/km
1357 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
37/2,20 ad-mm
Number and Wire Diameter (Conductor)
24/2,20 ad-mm
Steel Wire Cross-Section
140,65 mm² mm²
Current Type
AC
Actual Code (New Standard)
95 / 141
Standard
GOST 839-80
95 / 16 (95,43 mm²)
13.5 mm
0.3007 Ω/km
385 kg/km
A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/4,50 ad-mm
Number and Wire Diameter (Conductor)
6/4,50 ad-mm
Steel Wire Cross-Section
15,9 mm² mm²
Current Type
AC
Actual Code (New Standard)
95 / 16
Standard
GOST 839-80
Title Type Language
ACSR (GOST) Ürün Alternatif Görseli PNG
ACSR (GOST) Ürün Ana Görseli PNG
ACSR (GOST) Ürün Kataloğu PDF
ACSR (GOST) Ürün Kataloğu PDF
ACSR (GOST) Ürün Kataloğu PDF
ACSR (GOST) Ürün Kataloğu PDF
ACSR (GOST) Ürün Kataloğu PDF
ACSR (GOST) Ürün Kesit Görseli JPG
ACSR (GOST) CE Kalite Sertifikası PDF
ACSR (GOST) GOST Kalite Sertifikası PDF
ACSR (GOST) TSE Kalite Sertifikası PDF
How can we help you?
Or
Adobestock 558884015 1