ACSR (EN)
Steel Reinforced Aluminium Conductors
Manufactured according to TS EN 50182 standards from aluminum wires and zinc-coated steel wires. Conductors are stranded concentrically in seven or more layers. If the conductor consists of multiple layers, adjacent layers are stranded in opposite directions. Production can be made according to DIN, BS, ASTM, NF, CSA, EN standards upon request. Used in medium and high voltage transmission lines.


Twisted
Technical Specifications
Product
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,00 ad-mm
Number and Wire Diameter (Conductor)
30/2,00 ad-mm
Steel Wire Cross-Section
22 mm² mm²
Current Type
AC
Old Code (Old Standard)
CANNA 116,2
Actual Code (New Standard)
94 - AL1 / 22 - ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,25 ad-mm
Number and Wire Diameter (Conductor)
30/2,25 ad-mm
Steel Wire Cross-Section
27,8 mm² mm²
Current Type
AC
Old Code (Old Standard)
CANNA 147,1
Actual Code (New Standard)
119 - AL1 / 28 - ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,50 ad-mm
Number and Wire Diameter (Conductor)
30/2,50 ad-mm
Steel Wire Cross-Section
34,4 mm² mm²
Current Type
AC
Old Code (Old Standard)
CANNA 181,6
Actual Code (New Standard)
147 - AL1 / 34 - ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,80 ad-mm
Number and Wire Diameter (Conductor)
30/2,80 ad-mm
Steel Wire Cross-Section
43,1 mm² mm²
Current Type
AC
Old Code (Old Standard)
CANNA 228
Actual Code (New Standard)
185 - AL1 / 43 - ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,15 ad-mm
Number and Wire Diameter (Conductor)
30/3,15 ad-mm
Steel Wire Cross-Section
54,6 mm² mm²
Current Type
AC
Old Code (Old Standard)
CANNA 288
Actual Code (New Standard)
234 - AL1 / 55 - ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
3/2,00 ad-mm
Number and Wire Diameter (Conductor)
9/2,00 ad-mm
Steel Wire Cross-Section
9,42 mm² mm²
Current Type
AC
Old Code (Old Standard)
CANNA 37,7
Actual Code (New Standard)
28 - AL1 / 9 - ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,00 ad-mm
Number and Wire Diameter (Conductor)
12/2,00 ad-mm
Steel Wire Cross-Section
22 mm² mm²
Current Type
AC
Old Code (Old Standard)
CANNA 59,7
Actual Code (New Standard)
38 - AL1 / 22 - ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,25 ad-mm
Number and Wire Diameter (Conductor)
12/2,25 ad-mm
Steel Wire Cross-Section
27,8 mm² mm²
Current Type
AC
Old Code (Old Standard)
CANNA 75,5
Actual Code (New Standard)
48 - AL1 / 28 - ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,50 ad-mm
Number and Wire Diameter (Conductor)
12/2,50 ad-mm
Steel Wire Cross-Section
34,4 mm² mm²
Current Type
AC
Old Code (Old Standard)
CANNA 93,3
Actual Code (New Standard)
59 - AL1 / 34 - ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,00 ad-mm
Number and Wire Diameter (Conductor)
30/2,00 ad-mm
Steel Wire Cross-Section
94,2 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-110
Actual Code (New Standard)
94-AL1 / 22-ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,25 ad-mm
Number and Wire Diameter (Conductor)
30/2,25 ad-mm
Steel Wire Cross-Section
119,3 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-145
Actual Code (New Standard)
119-AL1 / 28-ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,50 ad-mm
Number and Wire Diameter (Conductor)
30/2,50 ad-mm
Steel Wire Cross-Section
147,3 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-180
Actual Code (New Standard)
147-AL1 / 34-ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,68 ad-mm
Number and Wire Diameter (Conductor)
26/3,44 ad-mm
Steel Wire Cross-Section
241,6 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-280 HAWK
Actual Code (New Standard)
242-AL1 / 39-ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,38 ad-mm
Number and Wire Diameter (Conductor)
6/2,38 ad-mm
Steel Wire Cross-Section
26,7 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-30
Actual Code (New Standard)
27-AL1 / 4-ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,82 ad-mm
Number and Wire Diameter (Conductor)
54/2,85 ad-mm
Steel Wire Cross-Section
337,3 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-380 GULL
Actual Code (New Standard)
337-AL1 / 44-ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,08 ad-mm
Number and Wire Diameter (Conductor)
54/3,08 ad-mm
Steel Wire Cross-Section
402,3 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-455 CONDOR
Actual Code (New Standard)
402-AL1 / 44-ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,38 ad-mm
Number and Wire Diameter (Conductor)
54/3,38 ad-mm
Steel Wire Cross-Section
484,5 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-545 CARDINAL
Actual Code (New Standard)
485-AL1 / 63-ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,15 ad-mm
Number and Wire Diameter (Conductor)
6/3,15 ad-mm
Steel Wire Cross-Section
46,8 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-56
Actual Code (New Standard)
47-AL1 / 8-ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,19 ad-mm
Number and Wire Diameter (Conductor)
54/3,65 ad-mm
Steel Wire Cross-Section
565 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-635 FINCH
Actual Code (New Standard)
565-AL1 / 72-ST1A
Standard
EN 50182
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,78 ad-mm
Number and Wire Diameter (Conductor)
6/3,78 ad-mm
Steel Wire Cross-Section
67,3 mm² mm²
Current Type
AC
Old Code (Old Standard)
LA-78
Actual Code (New Standard)
67-AL1 / 11-ST1A
Standard
EN 50182