ACSR (DIN)
Steel Reinforced Aluminium Conductors
Manufactured according to TS EN 50182 standards from aluminum wires and zinc-coated steel wires. Conductors are stranded concentrically in seven or more layers. If the conductor consists of multiple layers, adjacent layers are stranded in opposite directions. Production can be made according to DIN, BS, ASTM, NF, CSA, EN standards upon request. Used in medium and high voltage transmission lines.


Twisted
Technical Specifications
Product
Current Carrying Capacity in Air
1580 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,87 ad-mm
Number and Wire Diameter (Conductor)
72/4,30 ad-mm
Steel Wire Cross-Section
45,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
1046 - AL1 / 45 -ST1A
Standard
EN 50182;DIN 48204
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,25 ad-mm
Number and Wire Diameter (Conductor)
14/3,10 ad-mm
Steel Wire Cross-Section
75,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
106 - AL1 / 76 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
410 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,90 ad-mm
Number and Wire Diameter (Conductor)
26/2,44 ad-mm
Steel Wire Cross-Section
19,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
122 - AL1 / 20 - ST1A
Standard
EN 50182;DIN 48204
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,60 ad-mm
Number and Wire Diameter (Conductor)
12/3,60 ad-mm
Steel Wire Cross-Section
71,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
122 - AL1 / 71 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
425 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,33 ad-mm
Number and Wire Diameter (Conductor)
30/2,33 ad-mm
Steel Wire Cross-Section
29,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
128 - AL1 / 30 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
470 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,10 ad-mm
Number and Wire Diameter (Conductor)
26/2,70 ad-mm
Steel Wire Cross-Section
24,2 mm² mm²
Current Type
AC
Actual Code (New Standard)
149 - AL1 / 24 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
105 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/1,80 ad-mm
Number and Wire Diameter (Conductor)
6/1,80 ad-mm
Steel Wire Cross-Section
2,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
15 - AL1 / 3 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
520 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,70 ad-mm
Number and Wire Diameter (Conductor)
30/2,70 ad-mm
Steel Wire Cross-Section
40,1 mm² mm²
Current Type
AC
Actual Code (New Standard)
172 - AL1 / 40 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
535 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,33 ad-mm
Number and Wire Diameter (Conductor)
26/3,00 ad-mm
Steel Wire Cross-Section
29,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
184 - AL1 / 30 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
590 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,49 ad-mm
Number and Wire Diameter (Conductor)
26/3,20 ad-mm
Steel Wire Cross-Section
34,1 mm² mm²
Current Type
AC
Actual Code (New Standard)
209 - AL1 / 34 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
610 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,00 ad-mm
Number and Wire Diameter (Conductor)
30/3,00 ad-mm
Steel Wire Cross-Section
49,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
212 - AL1 / 49 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
630 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,33 ad-mm
Number and Wire Diameter (Conductor)
24/3,50 ad-mm
Steel Wire Cross-Section
29,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
231 - AL1 / 30 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
140 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,25 ad-mm
Number and Wire Diameter (Conductor)
6/2,25 ad-mm
Steel Wire Cross-Section
4 mm² mm²
Current Type
AC
Actual Code (New Standard)
24 - AL1 / 4 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
645 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,68 ad-mm
Number and Wire Diameter (Conductor)
26/3,45 ad-mm
Steel Wire Cross-Section
39,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
243 - AL1 / 39 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
680 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,49 ad-mm
Number and Wire Diameter (Conductor)
24/3,74 ad-mm
Steel Wire Cross-Section
34,1 mm² mm²
Current Type
AC
Actual Code (New Standard)
264 - AL1 / 34 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
740 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,00 ad-mm
Number and Wire Diameter (Conductor)
26/3,86 ad-mm
Steel Wire Cross-Section
49,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
304 - AL1 / 47 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
740 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,68 ad-mm
Number and Wire Diameter (Conductor)
54/2,68 ad-mm
Steel Wire Cross-Section
39,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
305 - AL1 / 39 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
790 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,33 ad-mm
Number and Wire Diameter (Conductor)
48/3,00 ad-mm
Steel Wire Cross-Section
29,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
339 - AL1 / 30 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
170 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,70 ad-mm
Number and Wire Diameter (Conductor)
6/2,70 ad-mm
Steel Wire Cross-Section
5,7 mm² mm²
Current Type
AC
Actual Code (New Standard)
34 - AL1 / 6 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
840 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,00 ad-mm
Number and Wire Diameter (Conductor)
54/3,00 ad-mm
Steel Wire Cross-Section
49,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
382 - AL1 / 49 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
850 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,49 ad-mm
Number and Wire Diameter (Conductor)
48/3,20 ad-mm
Steel Wire Cross-Section
34,1 mm² mm²
Current Type
AC
Actual Code (New Standard)
386 - AL1 / 34 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
900 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,20 ad-mm
Number and Wire Diameter (Conductor)
54/3,20 ad-mm
Steel Wire Cross-Section
56,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
434 - AL1 / 56 - ST1A
Standard
EN 50182;DIN 48204
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,40 ad-mm
Number and Wire Diameter (Conductor)
14/2,00 ad-mm
Steel Wire Cross-Section
31,7 mm² mm²
Current Type
AC
Actual Code (New Standard)
44 - AL1 / 32 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
920 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,68 ad-mm
Number and Wire Diameter (Conductor)
48/3,45 ad-mm
Steel Wire Cross-Section
39,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
449 - AL1 / 39 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
210 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,20 ad-mm
Number and Wire Diameter (Conductor)
6/3,20 ad-mm
Steel Wire Cross-Section
8 mm² mm²
Current Type
AC
Actual Code (New Standard)
48 - AL1 / 8 - SAT1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
960 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,40 ad-mm
Number and Wire Diameter (Conductor)
54/3,40 ad-mm
Steel Wire Cross-Section
63,6 mm² mm²
Current Type
AC
Actual Code (New Standard)
490 - AL1 / 64 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
985 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,49 ad-mm
Number and Wire Diameter (Conductor)
45/3,74 ad-mm
Steel Wire Cross-Section
34,1 mm² mm²
Current Type
AC
Actual Code (New Standard)
494 - AL1 / 34 - ST1A
Standard
EN 50182;DIN 48204
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,33 ad-mm
Number and Wire Diameter (Conductor)
12/2,33 ad-mm
Steel Wire Cross-Section
29,8 mm² mm²
Current Type
AC
Actual Code (New Standard)
51 - AL1 / 30 - SAT1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
995 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,87 ad-mm
Number and Wire Diameter (Conductor)
48/3,68 ad-mm
Steel Wire Cross-Section
45,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
511 - AL1 / 45 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
1020 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,60 ad-mm
Number and Wire Diameter (Conductor)
54/3,60 ad-mm
Steel Wire Cross-Section
71,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
550 - AL1 / 71 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
1040 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,00 ad-mm
Number and Wire Diameter (Conductor)
48/3,86 ad-mm
Steel Wire Cross-Section
49,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
562 - AL1 / 49 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
1050 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,68 ad-mm
Number and Wire Diameter (Conductor)
45/4,02 ad-mm
Steel Wire Cross-Section
39,5 mm² mm²
Current Type
AC
Actual Code (New Standard)
571 - AL1 / 39 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
1120 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,87 ad-mm
Number and Wire Diameter (Conductor)
45/4,30 ad-mm
Steel Wire Cross-Section
45,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
653 - AL1 / 45 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
1150 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
19/2,40 ad-mm
Number and Wire Diameter (Conductor)
54/4,00 ad-mm
Steel Wire Cross-Section
86 mm² mm²
Current Type
AC
Actual Code (New Standard)
679 - AL1 / 86 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
290 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,44 ad-mm
Number and Wire Diameter (Conductor)
26/1,85 ad-mm
Steel Wire Cross-Section
11,4 mm² mm²
Current Type
AC
Actual Code (New Standard)
70 - AL1 / 11 - ST1A
Standard
EN 50182;DIN 48204
Current Carrying Capacity in Air
350 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,67 ad-mm
Number and Wire Diameter (Conductor)
26/2,15 ad-mm
Steel Wire Cross-Section
15,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
94 - AL1 / 15 - ST1A
Standard
EN 50182;DIN 48204
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,20 ad-mm
Number and Wire Diameter (Conductor)
12/3,20 ad-mm
Steel Wire Cross-Section
56,3 mm² mm²
Current Type
AC
Actual Code (New Standard)
97 - AL1 / 56 - ST1A
Standard
EN 50182;DIN 48204