ACSR (BS)
Steel Reinforced Aluminium Conductors
Manufactured according to TS EN 50182 standards from aluminum wires and zinc-coated steel wires. Conductors are stranded concentrically in seven or more layers. If the conductor consists of multiple layers, adjacent layers are stranded in opposite directions. Production can be made according to DIN, BS, ASTM, NF, CSA, EN standards upon request. Used in medium and high voltage transmission lines.


Twisted
Technical Specifications
Product
Current Carrying Capacity in Ground
278 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,57 ad-mm
Number and Wire Diameter (Conductor)
6/4,72 ad-mm
Steel Wire Cross-Section
13,5 mm² mm²
Current Type
AC
Old Code (Old Standard)
Dog
Actual Code (New Standard)
105 - AL1 / 14 - STA1
Standard
BS EN 50182
Current Carrying Capacity in Ground
273 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/4,72 ad-mm
Number and Wire Diameter (Conductor)
6/4,72 ad-mm
Steel Wire Cross-Section
17,5 mm² mm²
Current Type
AC
Old Code (Old Standard)
Hare
Actual Code (New Standard)
105 - AL1 / 17 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
67 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/1,50 ad-mm
Number and Wire Diameter (Conductor)
6/1,50 ad-mm
Steel Wire Cross-Section
1,77 mm² mm²
Current Type
AC
Old Code (Old Standard)
Mole
Actual Code (New Standard)
11 - AL1 / 2 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
323 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,36 ad-mm
Number and Wire Diameter (Conductor)
30/2,36 ad-mm
Steel Wire Cross-Section
30,6 mm² mm²
Current Type
AC
Old Code (Old Standard)
Tiger
Actual Code (New Standard)
131 - AL1 / 7 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
311 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/1,91 ad-mm
Number and Wire Diameter (Conductor)
26/2,54 ad-mm
Steel Wire Cross-Section
20,1 mm² mm²
Current Type
AC
Old Code (Old Standard)
Coyote
Actual Code (New Standard)
132 - AL1 / 14 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
314 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,05 ad-mm
Number and Wire Diameter (Conductor)
18/3,05 ad-mm
Steel Wire Cross-Section
7,31 mm² mm²
Current Type
AC
Old Code (Old Standard)
Cougar
Actual Code (New Standard)
132 - AL1 / 20 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
355 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,59 ad-mm
Number and Wire Diameter (Conductor)
30/2,59 ad-mm
Steel Wire Cross-Section
36,8 mm² mm²
Current Type
AC
Old Code (Old Standard)
Wolf
Actual Code (New Standard)
158 - AL1 / 31 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
349 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,35 ad-mm
Number and Wire Diameter (Conductor)
18/3,35 ad-mm
Steel Wire Cross-Section
8,8 mm² mm²
Current Type
AC
Old Code (Old Standard)
Dingo
Actual Code (New Standard)
159 - AL1 / 37 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
386 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,79 ad-mm
Number and Wire Diameter (Conductor)
30/2,79 ad-mm
Steel Wire Cross-Section
42,8 mm² mm²
Current Type
AC
Old Code (Old Standard)
Lynx
Actual Code (New Standard)
183 - AL1 / 9 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
383 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,61 ad-mm
Number and Wire Diameter (Conductor)
18/3,61 ad-mm
Steel Wire Cross-Section
10,2 mm² mm²
Current Type
AC
Old Code (Old Standard)
Caracal
Actual Code (New Standard)
184 - AL1 / 2 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
109 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,11 ad-mm
Number and Wire Diameter (Conductor)
6/2,11 ad-mm
Steel Wire Cross-Section
3,5 mm² mm²
Current Type
AC
Old Code (Old Standard)
Squirrel
Actual Code (New Standard)
21 - AL1 / 3 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
415 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,86 ad-mm
Number and Wire Diameter (Conductor)
18/3,86 ad-mm
Steel Wire Cross-Section
11,7 mm² mm²
Current Type
AC
Old Code (Old Standard)
Jaguar
Actual Code (New Standard)
211 - AL1 / 4 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
421 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,00 ad-mm
Number and Wire Diameter (Conductor)
30/3,00 ad-mm
Steel Wire Cross-Section
49,2 mm² mm²
Current Type
AC
Old Code (Old Standard)
Panther
Actual Code (New Standard)
212 - AL1 / 3 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
448 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,18 ad-mm
Number and Wire Diameter (Conductor)
30/3,18 ad-mm
Steel Wire Cross-Section
55,6 mm² mm²
Current Type
AC
Old Code (Old Standard)
Lion
Actual Code (New Standard)
238 - AL1 / 5 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
126 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,36 ad-mm
Number and Wire Diameter (Conductor)
6/2,36 ad-mm
Steel Wire Cross-Section
4,38 mm² mm²
Current Type
AC
Old Code (Old Standard)
Gopher
Actual Code (New Standard)
26 - AL1 / 4 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
481 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,35 ad-mm
Number and Wire Diameter (Conductor)
30/3,35 ad-mm
Steel Wire Cross-Section
61,7 mm² mm²
Current Type
AC
Old Code (Old Standard)
Bear
Actual Code (New Standard)
264 - AL1 / 6 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
134 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,59 ad-mm
Number and Wire Diameter (Conductor)
6/2,59 ad-mm
Steel Wire Cross-Section
5,27 mm² mm²
Current Type
AC
Old Code (Old Standard)
Weasel
Actual Code (New Standard)
32 - AL1 / 5 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
542 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,71 ad-mm
Number and Wire Diameter (Conductor)
30/3,71 ad-mm
Steel Wire Cross-Section
75,7 mm² mm²
Current Type
AC
Old Code (Old Standard)
Goat
Actual Code (New Standard)
324 - AL1 / 7 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
147 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/2,79 ad-mm
Number and Wire Diameter (Conductor)
6/2,79 ad-mm
Steel Wire Cross-Section
6,11 mm² mm²
Current Type
AC
Old Code (Old Standard)
Fox
Actual Code (New Standard)
37 - AL1 / 6 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
588 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,97 ad-mm
Number and Wire Diameter (Conductor)
54/2,97 ad-mm
Steel Wire Cross-Section
48,5 mm² mm²
Current Type
AC
Old Code (Old Standard)
Antelope
Actual Code (New Standard)
374 - AL1 / 11 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
592 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,99 ad-mm
Number and Wire Diameter (Conductor)
30/3,99 ad-mm
Steel Wire Cross-Section
87,5 mm² mm²
Current Type
AC
Old Code (Old Standard)
Sheep
Actual Code (New Standard)
375 - AL1 / 9 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
595 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,00 ad-mm
Number and Wire Diameter (Conductor)
54/3,00 ad-mm
Steel Wire Cross-Section
49,5 mm² mm²
Current Type
AC
Old Code (Old Standard)
Bison
Actual Code (New Standard)
382 - AL1 / 37 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
161 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,00 ad-mm
Number and Wire Diameter (Conductor)
6/3,00 ad-mm
Steel Wire Cross-Section
7,07 mm² mm²
Current Type
AC
Old Code (Old Standard)
Ferret
Actual Code (New Standard)
42 - AL1 / 7 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
635 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,18 ad-mm
Number and Wire Diameter (Conductor)
54/3,18 ad-mm
Steel Wire Cross-Section
55,6 mm² mm²
Current Type
AC
Old Code (Old Standard)
Zebra
Actual Code (New Standard)
429 - AL1 / 43 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
639 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/4,27 ad-mm
Number and Wire Diameter (Conductor)
30/4,27 ad-mm
Steel Wire Cross-Section
100,2 mm² mm²
Current Type
AC
Old Code (Old Standard)
Deer
Actual Code (New Standard)
430 - AL1 / 13 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
677 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,35 ad-mm
Number and Wire Diameter (Conductor)
54/3,35 ad-mm
Steel Wire Cross-Section
61,7 mm² mm²
Current Type
AC
Old Code (Old Standard)
Camel
Actual Code (New Standard)
476 - AL1 / 14 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
679 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/4,50 ad-mm
Number and Wire Diameter (Conductor)
30/4,50 ad-mm
Steel Wire Cross-Section
111,3 mm² mm²
Current Type
AC
Old Code (Old Standard)
Elk
Actual Code (New Standard)
477 - AL1 / 13 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
763 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/3,53 ad-mm
Number and Wire Diameter (Conductor)
54/3,53 ad-mm
Steel Wire Cross-Section
68,5 mm² mm²
Current Type
AC
Old Code (Old Standard)
Moose
Actual Code (New Standard)
528 - AL1 / 16 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
185 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,35 ad-mm
Number and Wire Diameter (Conductor)
6/3,35 ad-mm
Steel Wire Cross-Section
8,82 mm² mm²
Current Type
AC
Old Code (Old Standard)
Rabbit
Actual Code (New Standard)
53 - AL1 / 9 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
174 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,66 ad-mm
Number and Wire Diameter (Conductor)
6/3,66 ad-mm
Steel Wire Cross-Section
10,5 mm² mm²
Current Type
AC
Old Code (Old Standard)
Mink
Actual Code (New Standard)
63 - AL1 / 11 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
246 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,59 ad-mm
Number and Wire Diameter (Conductor)
12/2,59 ad-mm
Steel Wire Cross-Section
36,9 mm² mm²
Current Type
AC
Old Code (Old Standard)
Skunk
Actual Code (New Standard)
63 - AL1 / 37 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
268 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
7/2,79 ad-mm
Number and Wire Diameter (Conductor)
12/2,79 ad-mm
Steel Wire Cross-Section
42,83 mm² mm²
Current Type
AC
Old Code (Old Standard)
Horse
Actual Code (New Standard)
73 - AL1 / 43 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
193 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/3,99 ad-mm
Number and Wire Diameter (Conductor)
6/3,99 ad-mm
Steel Wire Cross-Section
12,5 mm² mm²
Current Type
AC
Old Code (Old Standard)
Beaver
Actual Code (New Standard)
75 - AL1 / 13 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
231 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/4,10 ad-mm
Number and Wire Diameter (Conductor)
6/4,10 ad-mm
Steel Wire Cross-Section
13,1 mm² mm²
Current Type
AC
Old Code (Old Standard)
Racoon
Actual Code (New Standard)
79 - AL1 / 13 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
240 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/4,22 ad-mm
Number and Wire Diameter (Conductor)
6/4,22 ad-mm
Steel Wire Cross-Section
14 mm² mm²
Current Type
AC
Old Code (Old Standard)
Otter
Actual Code (New Standard)
84 - AL1 / 14 - ST1A
Standard
BS EN 50182
Current Carrying Capacity in Ground
248 A
Conductor Structure
Stranded Aluminum and Steel
Number and Wire Diameter (Steel)
1/4,50 ad-mm
Number and Wire Diameter (Conductor)
6/4,50 ad-mm
Steel Wire Cross-Section
15,9 mm² mm²
Current Type
AC
Old Code (Old Standard)
Cat
Actual Code (New Standard)
95 - AL1 / 16 - ST1A
Standard
BS EN 50182