ABC (HD)

XLPE Insulated Aerial Bundled Conductor Aluminium Power Cables
More secure against short circuits and impacts compared to bare overhead conductors. This type of cable is preferred in various applications for more efficient and safe transmission of network power. These cables are particularly used in village electrification and densely populated areas where underground cabled facilities are very expensive.

Twisted
Technical Specifications
Product
2x16 mm²
15 mm
1.91 Ω/km
130.88 kg/km
A
Current Carrying Capacity in Air
65 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
2x25 mm²
18.5 mm
1.2 Ω/km
187.35 kg/km
A
Current Carrying Capacity in Air
83 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
2x35 mm²
20 mm
0.868 Ω/km
242.26 kg/km
A
Current Carrying Capacity in Air
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
2x50 mm²
24 mm
0.641 Ω/km
328.81 kg/km
A
Current Carrying Capacity in Air
124 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
2x70 mm²
26 mm
0.443 Ω/km
453.49 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x120 mm²
36 mm
0.253 Ω/km
1156.37 kg/km
A
Current Carrying Capacity in Air
221 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x120+70 mm²
46 mm
0.253 Ω/km
1390.93 kg/km
A
Current Carrying Capacity in Air
221 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x120+70+16 mm²
47 mm
0.253 Ω/km
1454.07 kg/km
A
Current Carrying Capacity in Air
221 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x150 mm²
38 mm
0.206 Ω/km
1401.24 kg/km
A
Current Carrying Capacity in Air
252 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x150+70 mm²
48 mm
0.206 Ω/km
1635.68 kg/km
A
Current Carrying Capacity in Air
252 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x150+70+16 mm²
49 mm
0.206 Ω/km
1698.81 kg/km
A
Current Carrying Capacity in Air
252 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x16 mm²
16 mm
1.91 Ω/km
196.99 kg/km
A
Current Carrying Capacity in Air
65 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x16+10 mm²
26 mm
1.91 Ω/km
241.27 kg/km
A
Current Carrying Capacity in Air
65 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x25 mm²
20 mm
1.2 Ω/km
281.87 kg/km
A
Current Carrying Capacity in Air
83 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x25+16 mm²
28 mm
1.2 Ω/km
352.86 kg/km
A
Current Carrying Capacity in Air
83 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x25+16+16 mm²
28 mm
1.2 Ω/km
415 kg/km
A
Current Carrying Capacity in Air
83 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x35 mm²
22 mm
0.868 Ω/km
364.4 kg/km
A
Current Carrying Capacity in Air
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x35+16 mm²
31 mm
0.868 Ω/km
434.31 kg/km
A
Current Carrying Capacity in Air
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x35+16+16 mm²
31 mm
0.868 Ω/km
497.45 kg/km
A
Current Carrying Capacity in Air
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x35+25 mm²
31 mm
0.868 Ω/km
462.87 kg/km
A
Current Carrying Capacity in Air
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x35+25+16 mm²
32 mm
0.868 Ω/km
525.01 kg/km
A
Current Carrying Capacity in Air
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x50 mm²
24 mm
0.641 Ω/km
494.58 kg/km
A
Current Carrying Capacity in Air
124 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x50+25 mm²
34 mm
0.641 Ω/km
591.83 kg/km
A
Current Carrying Capacity in Air
124 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x50+25+16 mm²
34 mm
0.641 Ω/km
654.97 kg/km
A
Current Carrying Capacity in Air
124 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x50+35+16 mm²
35 mm
0.641 Ω/km
683.6 kg/km
A
Current Carrying Capacity in Air
124 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x70 mm²
28 mm
0.443 Ω/km
681.92 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x70+25 mm²
38 mm
0.443 Ω/km
779.03 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x70+25+16 mm²
36 mm
0.443 Ω/km
842.17 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x70+35 mm²
38 mm
0.443 Ω/km
807.67 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x70+35+16 mm²
37 mm
0.443 Ω/km
870.81 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x70+50+16 mm²
40 mm
0.443 Ω/km
915.32 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x95 mm²
32 mm
0.32 Ω/km
948.22 kg/km
A
Current Carrying Capacity in Air
190 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x95+35+16 mm²
42 mm
0.32 Ω/km
1136.77 kg/km
A
Current Carrying Capacity in Air
190 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x95+50 mm²
42 mm
0.32 Ω/km
1118.15 kg/km
A
Current Carrying Capacity in Air
190 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x95+50+16 mm²
44 mm
0.32 Ω/km
1181.29 kg/km
A
Current Carrying Capacity in Air
190 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
3x95+70+16 mm²
46 mm
0.32 Ω/km
1246.06 kg/km
A
Current Carrying Capacity in Air
190 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
4x120 mm²
40 mm
0.253 Ω/km
1543.07 kg/km
A
Current Carrying Capacity in Air
221 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
4x150 mm²
44 mm
0.206 Ω/km
1869.86 kg/km
A
Current Carrying Capacity in Air
252 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
4x16 mm²
18 mm
1.91 Ω/km
262.82 kg/km
A
Current Carrying Capacity in Air
65 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
4x25 mm²
22 mm
1.2 Ω/km
376.09 kg/km
A
Current Carrying Capacity in Air
83 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
4x35 mm²
26 mm
0.868 Ω/km
486.22 kg/km
A
Current Carrying Capacity in Air
102 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
4x50 mm²
28 mm
0.641 Ω/km
659.92 kg/km
A
Current Carrying Capacity in Air
124 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
4x70 mm²
32 mm
0.443 Ω/km
909.94 kg/km
A
Current Carrying Capacity in Air
158 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1
4x95 mm²
36 mm
0.32 Ω/km
1265.28 kg/km
A
Current Carrying Capacity in Air
190 A
Conductor Structure
Stranded Aluminum (Class 2)
Test Voltage (AC)
4000 VAC
Insulation
XLPE
Current Type
AC
Minimum Bending Radius
12 x D mm
Temperature Range
90 °C
Minimum Installation Temperature
5 °C
Short Circuit Temperature
250 °C
Standard
HD 626
Flame Retardant Test
IEC 60332-1