AAC (IEC)

All Aluminium Conductors
Pure Aluminum Conductors are manufactured according to TS EN 50182 standards. Conductors are stranded concentrically in seven or more layers. If the conductor consists of multiple layers, adjacent layers are stranded in opposite directions. Production can be made according to DIN, BS, ASTM, CSA, NF, EN standards upon request. Used in low voltage distribution lines.

Twisted
Technical Specifications
Product
16 mm²
5.12 mm
1.7896 Ω/km
43.8 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 1,71 ad-mm
Current Type
AC
Standard
IEC 61089
25 mm²
6.4 mm
1.1453 Ω/km
68.4 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 2,13 ad-mm
Current Type
AC
Standard
IEC 61089
40 mm²
8.09 mm
0.7158 Ω/km
109.4 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 2,70 ad-mm
Current Type
AC
Standard
IEC 61089
63 mm²
10.2 mm
0.4545 Ω/km
172.3 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 3,39 ad-mm
Current Type
AC
Standard
IEC 61089
100 mm²
12.9 mm
0.2877 Ω/km
274.8 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 2,59 ad-mm
Current Type
AC
Standard
IEC 61089
125 mm²
14.5 mm
0.2302 Ω/km
343.8 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 2,89 ad-mm
Current Type
AC
Standard
IEC 61089
160 mm²
16.4 mm
0.1798 Ω/km
439.8 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,27 ad-mm
Current Type
AC
Standard
IEC 61089
200 mm²
18.3 mm
0.1439 Ω/km
549.7 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,66 ad-mm
Current Type
AC
Standard
IEC 61089
250 mm²
20.5 mm
0.1151 Ω/km
687.1 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 4,09 ad-mm
Current Type
AC
Standard
IEC 61089
315 mm²
23 mm
0.0916 Ω/km
867.9 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,29 ad-mm
Current Type
AC
Standard
IEC 61089
400 mm²
26 mm
0.0721 Ω/km
1102 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,71 ad-mm
Current Type
AC
Standard
IEC 61089
450 mm²
27.5 mm
0.0641 Ω/km
1239.8 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,94 ad-mm
Current Type
AC
Standard
IEC 61089
500 mm²
29 mm
0.0577 Ω/km
1377.6 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 4,15 ad-mm
Current Type
AC
Standard
IEC 61089
560 mm²
30.7 mm
0.0515 Ω/km
1542.9 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 4,39 ad-mm
Current Type
AC
Standard
IEC 61089
630 mm²
32.6 mm
0.0458 Ω/km
1738.3 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,63 ad-mm
Current Type
AC
Standard
IEC 61089
710 mm²
34.6 mm
0.0407 Ω/km
1959.1 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,85 ad-mm
Current Type
AC
Standard
IEC 61089
800 mm²
36.8 mm
0.0361 Ω/km
2207.4 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 4,09 ad-mm
Current Type
AC
Standard
IEC 61089
900 mm²
39 mm
0.0321 Ω/km
2483.3 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 4,33 ad-mm
Current Type
AC
Standard
IEC 61089
1000 mm²
41.1 mm
0.0289 Ω/km
2759.2 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 4,57 ad-mm
Current Type
AC
Standard
IEC 61089
1120 mm²
43.5 mm
0.0258 Ω/km
3093.5 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
91 / 3,96 ad-mm
Current Type
AC
Standard
IEC 61089
1250 mm²
46 mm
0.0231 Ω/km
3452.6 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
91 / 4,18 ad-mm
Current Type
AC
Standard
IEC 61089
1400 mm²
48.7 mm
0.0207 Ω/km
3866.9 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
91 / 4,43 ad-mm
Current Type
AC
Standard
IEC 61089
1500 mm²
50.4 mm
0.0193 Ω/km
4143.1 kg/km
A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
91 / 4,58 ad-mm
Current Type
AC
Standard
IEC 61089