AAC (CSA)

All Aluminium Conductors
Pure Aluminum Conductors are manufactured according to TS EN 50182 standards. Conductors are stranded concentrically in seven or more layers. If the conductor consists of multiple layers, adjacent layers are stranded in opposite directions. Production can be made according to DIN, BS, ASTM, CSA, NF, EN standards upon request. Used in low voltage distribution lines.

Twisted
Technical Specifications
Product
202,71 mm²
18.43 mm
0.1421 Ω/km
558 kg/km
A
Current Carrying Capacity in Air
402 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,68 ad-mm
Current Type
AC
Standard
CSA C 49
278,71 mm²
21.67 mm
0.1033 Ω/km
768 kg/km
A
Current Carrying Capacity in Air
485 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,09 ad-mm
Current Type
AC
Standard
CSA C 49
405,35 mm²
26.14 mm
0.0712 Ω/km
1118 kg/km
A
Current Carrying Capacity in Air
608 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,73 ad-mm
Current Type
AC
Standard
CSA C 49
557,35 mm²
30.7 mm
0.0518 Ω/km
1539 kg/km
A
Current Carrying Capacity in Air
733 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,41 ad-mm
Current Type
AC
Standard
CSA C 49
608,06 mm²
32.08 mm
0.0476 Ω/km
1679 kg/km
A
Current Carrying Capacity in Air
771 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,56 ad-mm
Current Type
AC
Standard
CSA C 49
658,71 mm²
33.37 mm
0.044 Ω/km
1818 kg/km
A
Current Carrying Capacity in Air
807 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,70 ad-mm
Current Type
AC
Standard
CSA C 49
709,42 mm²
34.63 mm
0.0407 Ω/km
1958 kg/km
A
Current Carrying Capacity in Air
842 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,84 ad-mm
Current Type
AC
Standard
CSA C 49
760,06 mm²
35.85 mm
0.0381 Ω/km
2098 kg/km
A
Current Carrying Capacity in Air
877 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,98 ad-mm
Current Type
AC
Standard
CSA C 49
810,71 mm²
37.04 mm
0.0358 Ω/km
2238 kg/km
A
Current Carrying Capacity in Air
910 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 4,11 ad-mm
Current Type
AC
Standard
CSA C 49
861,42 mm²
38.15 mm
0.0335 Ω/km
2378 kg/km
A
Current Carrying Capacity in Air
942 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 4,23 ad-mm
Current Type
AC
Standard
CSA C 49
912,06 mm²
39.28 mm
0.0316 Ω/km
2521 kg/km
A
Current Carrying Capacity in Air
975 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,57 ad-mm
Current Type
AC
Standard
CSA C 49
Anemone (443,1 mm²)
27.33 mm
0.0653 Ω/km
1222 kg/km
A
Current Carrying Capacity in Air
641 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,90 ad-mm
Current Type
AC
Actual Code (New Standard)
Anemone
Standard
CSA C 49
Arbutus (402,84 mm²)
26.06 mm
0.0715 Ω/km
1112 kg/km
A
Current Carrying Capacity in Air
605 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,72 ad-mm
Current Type
AC
Actual Code (New Standard)
Arbutus
Standard
CSA C 49
Aster (67,42 mm²)
10.51 mm
0.4236 Ω/km
184 kg/km
A
Current Carrying Capacity in Air
207 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 3,50 ad-mm
Current Type
AC
Actual Code (New Standard)
Aster
Standard
CSA C 49
Bluebell (523,68 mm²)
29.72 mm
0.0551 Ω/km
1445 kg/km
A
Current Carrying Capacity in Air
706 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 4,24 ad-mm
Current Type
AC
Actual Code (New Standard)
Bluebell
Standard
CSA C 49
Canna (201,42 mm²)
18.36 mm
0.1427 Ω/km
554 kg/km
A
Current Carrying Capacity in Air
401 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,67 ad-mm
Current Type
AC
Actual Code (New Standard)
Canna
Standard
CSA C 49
Carnation (725,1 mm²)
35.03 mm
0.04 Ω/km
2004 kg/km
A
Current Carrying Capacity in Air
854 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,89 ad-mm
Current Type
AC
Actual Code (New Standard)
Carnation
Standard
CSA C 49
Cockscomb (456,06 mm²)
27.73 mm
0.0633 Ω/km
1257 kg/km
A
Current Carrying Capacity in Air
657 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,96 ad-mm
Current Type
AC
Actual Code (New Standard)
Cockscomb
Standard
CSA C 49
Columbine (684,84 mm²)
34.01 mm
0.0423 Ω/km
1893 kg/km
A
Current Carrying Capacity in Air
825 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,78 ad-mm
Current Type
AC
Actual Code (New Standard)
Columbine
Standard
CSA C 49
Corepsis (805,68 mm²)
36.91 mm
0.0358 Ω/km
2226 kg/km
A
Current Carrying Capacity in Air
907 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 4,09 ad-mm
Current Type
AC
Actual Code (New Standard)
Corepsis
Standard
CSA C 49
Cosmos (241,68 mm²)
20.12 mm
0.1188 Ω/km
664 kg/km
A
Current Carrying Capacity in Air
447 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 4,02 ad-mm
Current Type
AC
Actual Code (New Standard)
Cosmos
Standard
CSA C 49
Daffodil (177,35 mm²)
17.24 mm
0.1624 Ω/km
488 kg/km
A
Current Carrying Capacity in Air
373 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,44 ad-mm
Current Type
AC
Actual Code (New Standard)
Daffodil
Standard
CSA C 49
Dahlia (282 mm²)
21.73 mm
0.1018 Ω/km
774 kg/km
A
Current Carrying Capacity in Air
489 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 4,34 ad-mm
Current Type
AC
Actual Code (New Standard)
Dahlia
Standard
CSA C 49
Daisy (135,16 mm²)
14.9 mm
0.2113 Ω/km
369 kg/km
A
Current Carrying Capacity in Air
313 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 4,96 ad-mm
Current Type
AC
Actual Code (New Standard)
Daisy
Standard
CSA C 49
Gladiolus (765,35 mm²)
35.99 mm
0.0377 Ω/km
2116 kg/km
A
Current Carrying Capacity in Air
881 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,99 ad-mm
Current Type
AC
Actual Code (New Standard)
Gladiolus
Standard
CSA C 49
Goldentuft (228 mm²)
19.55 mm
0.1263 Ω/km
626 kg/km
A
Current Carrying Capacity in Air
432 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,90 ad-mm
Current Type
AC
Actual Code (New Standard)
Goldentuft
Standard
CSA C 49
Hawkweed (506,71 mm²)
29.23 mm
0.0568 Ω/km
1396 kg/km
A
Current Carrying Capacity in Air
693 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 4,17 ad-mm
Current Type
AC
Actual Code (New Standard)
Hawkweed
Standard
CSA C 49
Hawthorn (604,26 mm²)
31.95 mm
0.0479 Ω/km
1670 kg/km
A
Current Carrying Capacity in Air
767 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,55 ad-mm
Current Type
AC
Actual Code (New Standard)
Hawthorn
Standard
CSA C 49
Heuchera (329,35 mm²)
23.56 mm
0.0876 Ω/km
908 kg/km
A
Current Carrying Capacity in Air
538 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,36 ad-mm
Current Type
AC
Actual Code (New Standard)
Heuchera
Standard
CSA C 49
Iris (33,61 mm²)
7.42 mm
0.8497 Ω/km
92 kg/km
A
Current Carrying Capacity in Air
136 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 2,47 ad-mm
Current Type
AC
Actual Code (New Standard)
Iris
Standard
CSA C 49
Laurel (135,16 mm²)
15.05 mm
0.2129 Ω/km
372 kg/km
A
Current Carrying Capacity in Air
317 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,01 ad-mm
Current Type
AC
Actual Code (New Standard)
Laurel
Standard
CSA C 49
Lily (26,65 mm²)
6.61 mm
1.072 Ω/km
73 kg/km
A
Current Carrying Capacity in Air
124 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 2,20 ad-mm
Current Type
AC
Actual Code (New Standard)
Lily
Standard
CSA C 49
Magnolia (483,42 mm²)
28.55 mm
0.0597 Ω/km
1333 kg/km
A
Current Carrying Capacity in Air
675 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 4,07 ad-mm
Current Type
AC
Actual Code (New Standard)
Magnolia
Standard
CSA C 49
Marigold (563,93 mm²)
30.89 mm
0.0512 Ω/km
1559 kg/km
A
Current Carrying Capacity in Air
738 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,43 ad-mm
Current Type
AC
Actual Code (New Standard)
Marigold
Standard
CSA C 49
Meadowsweet (304 mm²)
22.63 mm
0.0948 Ω/km
838 kg/km
A
Current Carrying Capacity in Air
513 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,23 ad-mm
Current Type
AC
Actual Code (New Standard)
Meadowsweet
Standard
CSA C 49
Narcissus (644,51 mm²)
33.02 mm
0.045 Ω/km
1781 kg/km
A
Current Carrying Capacity in Air
797 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
61 / 3,66 ad-mm
Current Type
AC
Actual Code (New Standard)
Narcissus
Standard
CSA C 49
Orchid (322,26 mm²)
23.31 mm
0.0896 Ω/km
888 kg/km
A
Current Carrying Capacity in Air
531 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,33 ad-mm
Current Type
AC
Actual Code (New Standard)
Orchid
Standard
CSA C 49
Oxlip (107,23 mm²)
13.25 mm
0.2664 Ω/km
293 kg/km
A
Current Carrying Capacity in Air
273 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 4,41 ad-mm
Current Type
AC
Actual Code (New Standard)
Oxlip
Standard
CSA C 49
Pansy (42,39 mm²)
8.33 mm
0.6739 Ω/km
116 kg/km
A
Current Carrying Capacity in Air
157 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 2,77 ad-mm
Current Type
AC
Actual Code (New Standard)
Pansy
Standard
CSA C 49
Patunia (380 mm²)
25.32 mm
0.0758 Ω/km
1048 kg/km
A
Current Carrying Capacity in Air
585 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,61 ad-mm
Current Type
AC
Actual Code (New Standard)
Patunia
Standard
CSA C 49
Peony (152 mm²)
15.97 mm
0.188 Ω/km
417 kg/km
A
Current Carrying Capacity in Air
340 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,19 ad-mm
Current Type
AC
Actual Code (New Standard)
Peony
Standard
CSA C 49
Phlo x (85,03 mm²)
11.8 mm
0.336 Ω/km
232 kg/km
A
Current Carrying Capacity in Air
237 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 3,93 ad-mm
Current Type
AC
Actual Code (New Standard)
Phlo x
Standard
CSA C 49
Poppy (53,48 mm²)
9.36 mm
0.5341 Ω/km
146 kg/km
A
Current Carrying Capacity in Air
180 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 3,12 ad-mm
Current Type
AC
Actual Code (New Standard)
Poppy
Standard
CSA C 49
Rose (21,16 mm²)
5.89 mm
1.351 Ω/km
58 kg/km
A
Current Carrying Capacity in Air
104 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 1,96 ad-mm
Current Type
AC
Actual Code (New Standard)
Rose
Standard
CSA C 49
Tulip (170,45 mm²)
16.91 mm
0.1638 Ω/km
467 kg/km
A
Current Carrying Capacity in Air
364 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,38 ad-mm
Current Type
AC
Actual Code (New Standard)
Tulip
Standard
CSA C 49
Valerian (126,71 mm²)
14.57 mm
0.2274 Ω/km
348 kg/km
A
Current Carrying Capacity in Air
305 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 2,91 ad-mm
Current Type
AC
Actual Code (New Standard)
Valerian
Standard
CSA C 49
Varbena (354,71 mm²)
24.45 mm
0.0814 Ω/km
978 kg/km
A
Current Carrying Capacity in Air
562 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,49 ad-mm
Current Type
AC
Actual Code (New Standard)
Varbena
Standard
CSA C 49
Violet (362,58 mm²)
24.74 mm
0.0797 Ω/km
1000 kg/km
A
Current Carrying Capacity in Air
570 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,53 ad-mm
Current Type
AC
Actual Code (New Standard)
Violet
Standard
CSA C 49
Zinnia (253,35 mm²)
20.6 mm
0.1132 Ω/km
695 kg/km
A
Current Carrying Capacity in Air
459 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 4,12 ad-mm
Current Type
AC
Actual Code (New Standard)
Zinnia
Standard
CSA C 49
Title Type Language
AAC (CSA) Ürün Alternatif Görseli PNG
AAC (CSA) Ürün Ana Görseli PNG
AAC (CSA) Ürün Kataloğu PDF
AAC (CSA) Ürün Kataloğu PDF
AAC (CSA) Ürün Kataloğu PDF
AAC (CSA) Ürün Kesit Görseli JPG
AAC (CSA) CE Kalite Sertifikası PDF
AAC (CSA) TSE Kalite Sertifikası PDF
How can we help you?
Or
Adobestock 558884015 1