AAC (BS)
All Aluminium Conductors
Pure Aluminum Conductors are manufactured according to TS EN 50182 standards. Conductors are stranded concentrically in seven or more layers. If the conductor consists of multiple layers, adjacent layers are stranded in opposite directions. Production can be made according to DIN, BS, ASTM, CSA, NF, EN standards upon request. Used in low voltage distribution lines.


Twisted
Technical Specifications
Product
Current Carrying Capacity in Air
274 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 2,67 ad-mm
Current Type
AC
Old Code (Old Standard)
Beetle
Actual Code (New Standard)
106 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
271 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 4,39 ad-mm
Current Type
AC
Old Code (Old Standard)
Wasp
Actual Code (New Standard)
106 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
308 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 4,90 ad-mm
Current Type
AC
Old Code (Old Standard)
Bee
Actual Code (New Standard)
132 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
346 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,25 ad-mm
Current Type
AC
Old Code (Old Standard)
Hornet
Actual Code (New Standard)
158 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
380 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,53 ad-mm
Current Type
AC
Old Code (Old Standard)
Caterpillar
Actual Code (New Standard)
186 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
414 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,78 ad-mm
Current Type
AC
Old Code (Old Standard)
Chafer
Actual Code (New Standard)
213 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
114 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 2,06 ad-mm
Current Type
AC
Old Code (Old Standard)
Midge
Actual Code (New Standard)
23 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
439 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 3,99 ad-mm
Current Type
AC
Old Code (Old Standard)
Spider
Actual Code (New Standard)
238 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
470 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 4,22 ad-mm
Current Type
AC
Old Code (Old Standard)
Cockroach
Actual Code (New Standard)
266 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
124 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 2,21 ad-mm
Current Type
AC
Old Code (Old Standard)
Gnat
Actual Code (New Standard)
27 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
528 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 4,65 ad-mm
Current Type
AC
Old Code (Old Standard)
Butterfl y
Actual Code (New Standard)
323 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
144 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 2,59 ad-mm
Current Type
AC
Old Code (Old Standard)
Mosquito
Actual Code (New Standard)
37 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
572 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,58 ad-mm
Current Type
AC
Old Code (Old Standard)
Drone
Actual Code (New Standard)
372 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
619 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 3,78 ad-mm
Current Type
AC
Old Code (Old Standard)
Centipede
Actual Code (New Standard)
373 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
572 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
19 / 5,00 ad-mm
Current Type
AC
Old Code (Old Standard)
Moth
Actual Code (New Standard)
415 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
159 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 2,79 ad-mm
Current Type
AC
Old Code (Old Standard)
Ladybird
Actual Code (New Standard)
43 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
676 A
Conductor Structure
Stranded Aluminum (Class 2)
Current Type
AC
Old Code (Old Standard)
Maybug
Actual Code (New Standard)
486 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
181 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 3,10 ad-mm
Current Type
AC
Old Code (Old Standard)
Ant
Actual Code (New Standard)
53 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
710 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 4,27 ad-mm
Current Type
AC
Old Code (Old Standard)
Scorpion
Actual Code (New Standard)
530 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
784 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
37 / 4,65 ad-mm
Current Type
AC
Old Code (Old Standard)
Cicada
Actual Code (New Standard)
628 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
199 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 3,40 ad-mm
Current Type
AC
Old Code (Old Standard)
Fly
Actual Code (New Standard)
64 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
219 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 3,66 ad-mm
Current Type
AC
Old Code (Old Standard)
Bluebottle
Actual Code (New Standard)
74 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
227 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 3,78 ad-mm
Current Type
AC
Old Code (Old Standard)
Earwig
Actual Code (New Standard)
79 - AL1
Standard
BS EN 50182
Current Carrying Capacity in Air
238 A
Conductor Structure
Stranded Aluminum (Class 2)
Number and Wire Diameter (Conductor)
7 / 3,91 ad-mm
Current Type
AC
Old Code (Old Standard)
Grasshopper
Actual Code (New Standard)
84 - AL1
Standard
BS EN 50182